Roentgen stereophotogrammetric analysis (RSA) is the most accurate radiographic technique for the assessment of three-dimensional micromotion in joints. RSA has been used previously to study the kinematics of the anterior cruciate ligament (ACL)-deficient knee and to measure knee laxity after bone-tendon-bone (BTB) reconstructions. There is no published evidence on its use in assessing hamstring grafts in vivo, in comparing hamstring versus BTB reconstruction, or in-depth analyses of graft performance. The aim of this project was to use RSA to measure laxity in both BTB and hamstring reconstructions, and to attempt a detailed analysis of graft behaviour in both reconstructions, with particular attention to graft stretching and slippage of the bony attachments. A prospective study was undertaken on 14 patients who underwent ACL reconstruction. Seven had BTB reconstruction, and seven had four-stranded semitendinosus/gracilis (STG). Tantalum markers were inserted at the time of surgery, into distal femur and proximal tibia, and also directly into the graft itself. Stress radiographs (90N anterior and 90N posterior force) were taken early post-operatively, and then at 6 weeks, and 3, 6 and 12 months. In addition to measuring total anteroposterior knee laxity, a detailed analysis of the graft itself was possible. The BTB grafts had stretched by an average of 1.54%, and the bone plugs had migrated by 0.50 mm at the femoral end and by 0.61mm at the tibial end. The hamstring grafts had stretched on average 3.94%, and the intraosseous ends had migrated by 3.96mm at the femoral end and by 7.10mm at the tibial end. This is believed to be the most detailed application of RSA in analysing the performance of the two commonly used grafts in ACL reconstruction. Details such as graft stretching and fixation slippage have not been available previously; the data obtained in this study may have implications for clinical practice.
A recurrence of objectively measured knee laxity after anterior cruciate ligament (ACL) reconstruction has previously been reported in various papers; the purpose of this study was to accurately measure in vivo knee laxity after both bone-tendon-bone (BTB) and hamstring reconstruction using radiostereometric analysis (RSA), and to differentiate between graft fixation slippage and graft stretching and their relative contributions to any increase in laxity. Twenty patients were studied prospectively after ACL reconstruction. Ten had been operated on using BTB grafts, and ten using hamstring (four-stranded semitendinosus/gracilis) grafts. Tantalum markers were inserted in the distal femur, proximal tibia and into the graft itself. (RSA) was used to measure sagittal laxity, graft stretching and fixation slippage early post-operatively, and then at intervals up to 1 year. A steady increase in total anteroposterior laxity was found in both groups over the year. For the BTB group, total mean slippage of the bone plugs increased to 1.28 mm at 1 year. For the hamstring group, the tunnel attachments had slipped by a total of 6.82 mm. More stretching was found for the hamstrings grafts than for the BTB grafts and the amount of stretching increased significantly with time post-surgery. The hamstring grafts stretched by a mean of 4.18%, the BTB grafts by 1.18%. This is believed to be the most detailed application of RSA in analysing the performance of the two commonly used grafts in ACL reconstruction. Details such as graft stretching and fixation slippage have not been available previously; the data obtained in this study may have implications for clinical practice.
In 90 patients undergoing primary THA, leg length discrepancy (LLD) and hip function were assessed pre-operatively and 3 and 12 months postoperatively. Hip function was measured by the Oxford hip score (OHS). Postoperatively the mean OHS improved by 26 points out of a possible 48 at 3 months and by 30 points at 12 months. Postoperatively 62% of patients’ limbs were lengthened by a mean of 9 mm. The LLD was perceived by 43% of the affected patients at 3 months and by 33% at 12 months. The OHS in patients who perceived true lengthening was 27% worse than in the other patients at 3 months and 18% worse at 12 months. In 98%, lengthening occurred in the femoral component. The problem of LLD after THA is lengthening. Appropriate placement of the femoral component could reduce patients’ perception of this.