Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 131 - 131
1 May 2016
Kweon S Jeong K
Full Access

Purpose

This studyevaluated the results of the acetabular medial wall osteotomy to reconstruct the acetabulum in dysplastic hip during total hip athroplasty.

Materials and Methods

A total of 30 hips of 30 patients who underwent THA between March 1999 and October 2002 were clinically and radiogically evaluated. The average age at the time of operation was 46.5 years (range: 17 to 73 years), and the mean follow-up period was 5 years (range: 5.3 to 8.7 years). 26 cases, a cementless hemispherical acetabular cup and 4 cases, reinforced ring were inserted in the true acetabulum. Only 2 hips needed structural bone graft.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 130 - 130
1 May 2016
Kweon S Kim T Kim J Jeong K
Full Access

Purpose

The purpose of this study is to evaluate the clinical outcomes and and radiological findings of primary total hip arthroplasty(THA) performed by using cemented polished femoral stem.

Materials and Methods

We retrospectively reviewed 91 hips (84 patients) that had undergone primary THA with cemented polished femoral stem after follow-up more than 10 years. The mean age at surgery was 57 years old (47 to 75). Mean follow up period was 12. 8 years(10.1 to 14). Clinical evaluation was performed using Harris hip score. The radiographic evaluation was performed in terms of the cementing technique, including of subsidence within the cement mantle, radiolucent lines at the cement-bone or cement-stem interface, cortical hypertrophy, and calcar resorption.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 131 - 131
1 Mar 2010
Chun C Choi Y Jeong K
Full Access

The purpose of this study was to compare the clinical and radiological results of the PFC flex mobile bearing design with those of the LPS flex fixed bearing design in high-flex total knee arthroplasty.

Between January 2005 and November 2006, forty-six patients who received PFC flex mobile bearing prosthesis in one knee and LPS flex fixed bearing prosthesis in the contralateral knee followed up for a minimum 2 years were evaluated. Clinical results were assessed using the ROM, HSS score, the Knee rating systems of the knee society, WOMAC score and SF-36. Radiological results were evaluated tibio-femoral angle and loosening or osteolysis of components. We subdivided preoperative less 90 degree and more 90 degree in each group.

Mean ROM range of last follow up was increased to 131.1 degree in LPS group and 130.1 degree in PFC group. But there was no significant difference between the two groups. HSS score, knee pain and function score, WOMAC score, SF-36 score didn’t differ significantly between two groups. But descending stairs, rising from sitting, bending to the floor more improved significantly in LPS group. T-F angle was changed from preoperative 8.2 degree varus to a postoperative 4.8 degree valgus. No knee had aseptic loosening or osteolysis.

Postoperative ROM was increase significantly in both groups. We found no significant differences between the two groups with regard to clinical and radiological parameters excepts descending stairs, rising from sitting, bending to the floor in WOMAC score. There was no aseptic loosening or osteolysis but needed long term observation about these concerns.