Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 11 - 11
17 Nov 2023
Wahdan Q Solanke F Komperla S Edmonds C Amos L Yap RY Neal A Mallinder N Tomlinson JE Jayasuriya R
Full Access

Abstract

INTRODUCTION

In the NHS the structure of a “regular healthcare team” is no longer the case. The NHS is facing a workforce crisis where cross-covering of ward-based health professionals is at an all-time high, this includes nurses, doctors, therapists, pharmacists and clerks. Comprehensive post-operative care documentation is essential to maintain patient safety, reduce information clarification requests, delays in rehabilitation, treatment, and investigations. The value of complete surgical registry data is emerging, and in the UK this has recently become mandated, but the completeness of post-operative care documentation is not held to the same importance, and at present there is no published standard. This project summarises a 4-stage approach, including 6 audit cycles, >400 reviewed operation notes, over a 5 year period.

OBJECTIVE

To deliver a sustainable change in post operative care documentation practices through quality improvement frameworks.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 873 - 880
17 Nov 2023
Swaby L Perry DC Walker K Hind D Mills A Jayasuriya R Totton N Desoysa L Chatters R Young B Sherratt F Latimer N Keetharuth A Kenison L Walters S Gardner A Ahuja S Campbell L Greenwood S Cole A

Aims

Scoliosis is a lateral curvature of the spine with associated rotation, often causing distress due to appearance. For some curves, there is good evidence to support the use of a spinal brace, worn for 20 to 24 hours a day to minimize the curve, making it as straight as possible during growth, preventing progression. Compliance can be poor due to appearance and comfort. A night-time brace, worn for eight to 12 hours, can achieve higher levels of curve correction while patients are supine, and could be preferable for patients, but evidence of efficacy is limited. This is the protocol for a randomized controlled trial of ‘full-time bracing’ versus ‘night-time bracing’ in adolescent idiopathic scoliosis (AIS).

Methods

UK paediatric spine clinics will recruit 780 participants aged ten to 15 years-old with AIS, Risser stage 0, 1, or 2, and curve size (Cobb angle) 20° to 40° with apex at or below T7. Patients are randomly allocated 1:1, to either full-time or night-time bracing. A qualitative sub-study will explore communication and experiences of families in terms of bracing and research. Patient and Public Involvement & Engagement informed study design and will assist with aspects of trial delivery and dissemination.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_8 | Pages 5 - 5
1 Aug 2022
Wardell D Jayasuriya R Totton N Mills A Breakwell L Cole A
Full Access

Thermal sensors have been used in bracing research as self-reported diaries are inaccurate. Little is known about new low-profile sensors, optimal location within a brace, locational thermal micro-climate and effect of brace lining. Our objective is to Determine an optimal temperature threshold for sensor-measured and true wear time agreement. Identify optimal sensor location. Assess all factors to determine the best sensor option for the Bracing AdoleScent Idiopathic Scoliosis (BASIS) multicentre RCT.

Seven Orthotimer and five iButton (DS1925L) sensors were synchronised to record temperature at five-minute intervals. Three healthy participants donned a rigid spinal brace, embedded with both sensors across four anatomical locations (abdomen/axilla/lateral-gluteal/sacral). Universal-coordinated-time wear protocols were performed in/out-doors. Intraclass correlation coefficient (ICC) assessed sensor-measured and true wear time agreement at thresholds 15–36oC.

Optimal thresholds, determined by largest ICC estimate: Orthotimer: Abdomen=26oC, axilla=27oC, lateral-gluteal=24.5oC, sacral=22.5oC. iButton: Abdomen=26oC, axilla=27oC, lateral-gluteal=23.5oC, sacral=23.5oC. Warm-up time and error at optimal thresholds increased for moulded sensors covered with 6mm lining.

Location: anterior abdominal wall. Excellent reliability and higher optimal thresholds, less likely to be exceeded by ambient temperature; not a pressure area. Sensor: iButton, longer battery life and larger memory than Orthotimer; allows recording at 10 min intervals for life of brace. Orthotimer only able to record every 30 mins, increasing error between true and measured wear time; Orthotimer needs 6-monthly data download. Threshold: 26oC is optimal threshold to balance warm-up and cool-down times for accurately measuring wear time. Sensor should not be covered by lining foam as this significantly prolongs warm-up time.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 90 - 90
1 Mar 2021
Mahatma M Jayasuriya R Gossiel F Gallagher O Hughes D Buckley S Gordon A Hamer A Tomouk M Wilkinson JM
Full Access

Abstract

Objective

In this phase 2 clinical trial (EudraCT 2011-000541-20) we examined the effect of denosumab versus placebo on osteolytic lesion activity in patients undergoing revision surgery after THA.

Methods

Men and women ≥ 30 years old scheduled for revision surgery for symptomatic, radiologically-confirmed osteolysis were randomised (1:1) to receive either denosumab 60mg or placebo subcutaneously eight weeks prior to operation. At surgery, biopsies from the osteolytic membrane-bone interface were taken for histomorphometric analysis of osteoclast number, the primary outcome measure. Secondary outcome measures included other static histomorphometric indices and systemic bone turnover markers. Adverse events and patient-reported clinical outcome scores were recorded as safety endpoints.


Introduction

In rheumatoid (RA) patients undergoing total joint arthroplasty, evidence suggests methotrexate should be continued without increase in post-operative infection. Prednisolone increases post-operative infection risk, but cannot be stopped without risk of Addisonian events. Insufficient evidence exists to clarify perioperative biologic agent management. We currently stop biologics 2 weeks prior to operation and reintroduced following wound healing.

Patients/Materials & Methods

This service evaluation reviewed infection rates and length of stay in RA patients following lower-limb arthroplasty, on various anti-rheumatoid therapies across a 28-month period.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 545 - 545
1 Nov 2011
Jayasuriya R Hannon R Eastell R Stockley I Wilkinson J
Full Access

Measurements of biochemical markers of bone turnover have been explored as a diagnostic tool for the detection of osteolysis after THA, but their predictive value in individual subjects has been poor. One explanation for this low diagnostic utility is that the mechanism of bone resorption in osteolysis may be different to that occurring in other high bone turnover states, such as osteoporosis, where these markers were principally developed. The aim of this study was to examine the role of the biomarkers urinary ααCTX-I and serum CTX-MMP, that are released in pathological rather than physiological bone turnover states, for detecting periprosthetic osteolysis in a case control study of 23 subjects with osteolysis and 26 controls. All samples were collected between the hours of 0800 and 1000 following an overnight fast, and were assayed using standard techniques. The demographic characteristics of the subjects in both groups were similar. Serum CTX-MMP was greater in the osteolysis versus the control group (P=0.001). Urinary ααCTX-I was similar between osteolysis and control groups (P> 0.05). A cut-off value of 5.50ng/mL CTX-MMP had a sensitivity of 91% (95% CI: 72 to 99) and specificity of 69% (48 to 96) detecting osteolysis (P=0.001). The same cut-off had a sensitivity of 100% (100 to 100) and specificity of 63% (44 to 79) for detecting femoral osteolysis (P=0.0004), and a sensitivity of 89% (65 to 98) and specificity of 58% (39 to 75) for identifying pelvic osteolysis (P=0.014). Serum CTX-MMP shows promise for further investigation as a sensitive bio-marker for detecting periprosthetic osteolysis.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 545 - 545
1 Nov 2011
Jayasuriya R Buckley S Hamer A Kerry R Stockley I Tomouk M Wilkinson J
Full Access

In this 2-year randomised clinical trial we examined whether cemented femoral prosthesis geometry affects the pattern of strain-adaptive bone remodelling in the proximal femur after THA. 128 patients undergoing primary THA were randomised to receive a Charnley (shape-closed, no taper), Exeter (force-closed, double-tapered) or C-stem (forced-closed, triple-tapered) prosthesis. All received a cemented Charnley cup. Proximal femoral BMD change over 2 years was measured by DXA. Urine and serum samples were collected at pre-operative baseline and over 1 year post-operatively. N-telopeptides of type-I-collagen (NTX) was measured in urine as a marker of osteoclast activity and Osteocalcin (OC) in serum as a maker of osteoblast activity. Clinical outcome using the Harris and Oxford hip scores, and prosthesis migration measured using digitised radiographs (EBRA-Digital) were measured over 2 years. The baseline characteristics of the subjects in each group were similar (P> 0.05). Decreases in femoral BMD were observed over the first year for all prosthesis designs. Bone loss was greatest (14%) in the proximal medial femur (region 7). The pattern and amount of bone loss observed was similar between all prosthesis designs (P> 0.05). Transient rises in both osteoclast (NTX) and osteoblast (OC) activity also occurred over year 1, and were similar in pattern in the 3 prosthesis groups (p> 0.05). All prostheses showed migration patterns that were true to their design type and similar improvements in clinical hip scores were observed over the 2 year study. Differences in the proposed mechanism of load transfer between prosthesis and host bone in force-closed versus shape-closed femoral prosthesis designs in THA are not major determinants of prosthesis-related remodelling.