Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 54 - 54
1 Feb 2020
Ezaki A Sakata K Abe S Iwata H Nannno K Nakai T
Full Access

Introduction

Total knee arthroplasty (TKA) is an effective surgical intervention, which alleviates pain and improves function and health-related quality of life in patients with end-stage arthritis of the knee joint. With improvements in anesthesia, general health care, and surgical techniques, this procedure has become widely accepted for use in very elderly patients. However, many elderly patients tend to have compromised function and low reserve capabilities of organs and are therefore likely to develop various complications during the perioperative period. Thus, elderly patients often hesitate to undergo simultaneous bilateral TKA (SBTKA). Our purpose was to report the short-term results and clinical complications of octogenarians undergoing SBTKA.

Materials and Methods

Between 2015 and 2016 all patients greater than 80years of age who underwent SBTKA by a single surgeon were retrospectively evaluated demographics, comorbidity, complications, and 30days mortality following SBTKA. Arthroplasty was performed sequentially under general anesthesia by one team led by primary surgeon. After the first knee, the patient's cardiopulmonary status was assessed by anesthesiology to determine whether or not to begin the second side. Cardiopulmonary decompensation, such as significant shifts in heart rate, oxygen saturation or blood pressure, was not showed. Then the second procedure was undertaken. Inclusion criteria of this study was underlying diseases were osteoarthritis. Exclusion criteria were (1) previous knee surgery; (2) underlying diseases were osteonecrosis, rheumatoid arthritis, fracture, and others. Fifty-seven patients with an average age of 82.7years were identified. The results of these procedures were retrospectively compared with those of patients greater than 80years of age of 89 patients unilateral TKA (UTKA) that had been performed by the same surgeon.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 57 - 57
1 Feb 2020
Abe S Iwata H Ezaki A Ishida H Sakata K Matsuoka H Sogou E Nannno K Kuroda S Nakamura S Hayashi J Nakai T
Full Access

A-70-year old woman underwent uncomplicated total hip arthroplasty using a titanium modular stem with a 46mm CoCr femoral head, a titanium shell, and a metal linear (Wright Medical Technology). Eight years after implantation, she presented with a painful left hip. A pelvic radiograph revealed adequate positioning of both hip implants without any signs of wear of loosening. CT scanning confirmed the presence of a 5 × 5 cm soft tissue mass in the ilium above the cup component accompanied by the iliac fracture. The patient was diagnosed as having an adverse reaction to metal debris (ARMD) after a metal-on-metal THA and revision was performed. Perioperatively?tissue necrosis and partial destruction of the abductor mechanism were found in the absence of any macroscopic infection. Both the neck trunnion and bore of the head showed slight signs of corrosion. The modular neck was revised with a ceramic 28mm head and a new dual-mobility liner(Zimmer Biomet). The iliac fracture was fixed with a porous trabecular metal augment(Zimmer Biomet).

The histopathology of tissue sample revealed extensively necrotic material with focal cellular areas of inflammatory cells containing macrophages and neutrophilas. Metalic debris was also scattered in the necrotic materials. After the revision, the patient was recovered without pain or dislocation, and iliac fracture was well fixed.

Instability is a substantial problem in the revision of ARMD. Extensive necrosis with gross deficiency of the abductor mechanism is associated with postoperative dislocation. Revision of failed MoM THA a dual-mobility device an effective strategy.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 431 - 431
1 Apr 2004
Iwata H Ito H Hasegawa Y Ishiguro N Matsuda T Kitamura S Iyoda K Yabe Y Yamauchi K Kaneko H Maruno S
Full Access

Hydroxyapatite (HA) is a bioactive material with a high affinity for bone. Ti-6Al-4V is lightweight and less biotoxic. Using these materials, a cementless hip prosthesis has been clinically used, consisting mainly of a Ti femoral stem coated with plasma-sprayed biocompatible HA. However, this type of stem entails several disadvantages: HA is likely to decompose at the coating; long term HA coating layer bonding to Ti is unstable and optimal HA thickness is unfeasible. In many actual cases, debonding of HA coating layer from the Ti surface was found upon removal of stems.

To resolve these concerns, we started developing a new hip prosthesis using composite materials comprised of Ti-6Al-4V and HA containing bioinactive and highly stable glass in 1985. The cementless hip prosthesis, named HAPG-Profile, unites the bioactive stem surface with the surrounding bone via adhesive glass. In basic experiments, the glass-coated HAPG-Profile has been demonstrated to possess much higher bonding stability than the plasma-sprayed HA, with bone affinity and safety not compromised. On the basis of these results, we manufactured the HAPG-Profile jointly with DePuy International, UK, and initiated a clinical trial in January 1997 in the teaching Hospital, Nagoya University School of Medicine, and Tokyo Kosei Nenkin Hospital. A total of 63 patients were followed up for more than two year and evaluated according to the Japanese Orthopedic Association Score and Harris Hip Score (HHS) clinically, functionally and radiographically. The results of the two-year follow-up study indicated success of early fixation associated with favorable outcomes.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 13 - 13
1 Jan 2004
Iwata H Hirose K Takagi H Hosono K Yanase M
Full Access

The aim of the study was to evaluate THA using Robodoc system for osteoarthritis of the hip joint.

The Robodoc system consists of: 1. the Orthodoc computer workstation that simultaneously displays computerised tomography images of patient’s femur and a selected prosthesis, 2.a five-axis robot, 3.the operating room display, 4. the control cabinet.

Follow up were 3months and 1 year on 27cases (Male 5, Female 22). Selected stems: Zimmer anatomic, 13, Versis 14(VSS,7, VSL,7). Mean age 57.9. Among 27 cases of osteoarthritis, one is after osteotomy and two are after osteonecrosis. Pain, ROM, Radiographs and ADL were evaluated using JOA hip score system. Sockets were fixed with cementless conventional technique.

Mean operating time, 2 hours and 40min.; Mean bleeding, 455 ml; Mean Ant. Version, 29.26 degree (22.0–39.7); Level of osteotomy of the femur neck, Mean, 9.19 mm from the trochanter minor. JOA hip score after THA, 82.20. In one case, 5 mm sinking occurred 5 days after the operation. No intraoperative femoral fractures and varus or valgus insertion of stems occurred in 27cases. The thigh pains were nothing. The patients were discharged at 4weeks after the operation with one crutch. The results showed statistically better fit and fill of the femoral component in the Robodoc system.

The Robodoc system is thought to be safe and effective in producing radiographically superior implant fit and positioning without fractures and other complication. Precise fit of the implant may be increase bone-to-implant contact, providing stress transfer from prosthesis to bone and more bone growth into prosthesis.