In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component. Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years).Aims
Methods
The aim of this study was to assess medium-term improvements following total hip arthroplasty (THA), and to evaluate what effect different preoperative Oxford Hip Score (OHS) thresholds for treatment may have on patients’ access to THA and outcomes. Patients undergoing primary THA at our institution with an OHS both preoperatively and at least four years postoperatively were included. Rationing thresholds were explored to identify possible deprivation of OHS improvement.Aims
Methods
Retention of well fixed bone cement at the time of a revision THA is an attractive proposition, as its removal can be difficult, time consuming and may result in extensive bone stock loss or fracture. Previously reported poor results of cemented revision THA, however, have tended to discourage Surgeons from performing ‘cement in cement’ revisions, and this technique is not in widespread use. Since 1989 in Exeter, we have performed a ‘cement within cement’ femoral stem revision on 354 occasions. An Exeter polished tapered stem has been cemented into the existing cement mantle on each occasion. Clinical and radiological follow up of 5 years or longer is available for 156 cases. On no occasion has a cement in cement femoral stem had to be re-revised during this time for subsequent aseptic loosening. This has encouraged the refinement of this technique, including the development of a new short stem designed specifically for cement within cement revisions. This stem is designed to fit into an existing well fixed cement mantle of most designs of cemented femoral components or hemi-arthroplasties, with only limited preparation of the proximal mantle required. The new stem greatly simplifies cement in cement revision and minimises the risk of distal shaft perforation or fracture, which is otherwise a potential hazard when reaming out distal cement to accommodate a longer prosthesis.