Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 526 - 526
1 Nov 2011
Obert L Huard S Blanchet N Leclerc G Ghislandi X Rochet S Garbuio P
Full Access

Purpose of the study: Volar plate fixation is becoming increasingly popular for instable fractures of the distal radius or on porotic bone. We report our experience and unavoidable or predictable complications with this type of fixation.

Material and methods: The 142 patients who underwent surgery from 2006 to 208 were reviewed and followed prospectively. In 2006 and 200, three types of volar plates were implanted: the Ace Depuy (standard), the T or DRP (Synthes), prolock with locking screws, (ITS) with a series of 104 patients. In 2008, two types of new generation plates with a more anatomic design were used: Variax (Stryker) and Newclip with a series of 48 patients. Complications were noted with minimum four months follow-up.

Results: All fractures healed. The Herzberg score reached 81/100 and the DASH 19.4. The complication rate was 19% (n=19) for the older generation plates and 15% (n=7) for the new anatomic plates. The main complications were tears of the long flexor and long extensor pollicis tendons (two before 2008 and four after 2008), reflex dystrophy (five before 2008 and two after), carpal tunnel syndrome (n=4), and material problems (dislodged screw, protruding screw) with no functional consequences (six before 2008 and one after).

Discussion: The increasing popularity of plate fixation for distal radius fractures generates an increase in complications. These are predictable if the material protrudes (tendon tears caused by overly long screws). Three published series on these specific complications (Rozental 2006, Rampoldi and Arora 2007) found that these problems could be avoided, both by implant design and by surgical technique. Locking the epiphyseal screws requires insertion into the subchondral bone and thus distal implantation of the plates, generating an iatrogenic conflict for the flexors. The rediscovery of the anatomy of the distal radius should help avoid styloid problems, and reconsideration of plate design to avoid advancement both on the ulnar side and the radial side. While the extra-articular volar plates fulfil the same function as pinning (Obert 2006), plates have lower indirect costs than pinning + plaster cast (Candelier 2006). Conversely, there is still no proof of the superiority of locked screws over standard screws.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 531 - 531
1 Nov 2011
Serre A Couesmes A Gasse N Huard S Obert L Garbuio P
Full Access

Purpose of the study: Since the advent of locked centromedullary nailing, manufacturers have produced long nails with automatic distal locking systems. Astute instrumentations have been developed to achieve highly stable assemblies. But during insertion, the exact shape o the nail may change adapting to the anatomy of the medullary canal. We wanted to test a new automatic distal locking system: Surelock.

Material and methods: We conducted a preliminary monocentric prospective study over a one-month period where we included all cases of reconstruction of the proximal femur using a long nail. The Surelock system was applied systematically. The amplifier was needed to adjust the insertion device, the amplifier and the nail in the same plane. This configuration required manipulation of the amplifier in a single plane. The operator then had to correct the position of the insertion devise in accordance with the deformation of the inserted nail. It is noteworthy that with this system, the operator’s hands are never in the amplifier field. We measured the time required to achieve distal locking and the time of scopy, as well as any complications.

Results: During this period, ten patients had osteosynthesis with a long reconstruction nail. The epidemiological data were common for this type of condition. Mean time for the distal locking was 11 min (7–15) with a mean 17 s of scopy (2–24). In all cases, the two distal screws were inserted. The automatic locking was correct in 9 of 10 cases. The one failure was the second case in our series.

Discussion: In 2006, Whatling concluded a review of the literature on different means for distal locking that the search should continue for an ideal method and that by far the most widely used method was manual locking. The new method presented here for automatic distal locking allows implantation of two distal safety screws. The main benefit is for the surgeon and the manipulator of the amplifier. Radiation of the surgeon is nearly zero (the surgeon remains outside the amplifier field) and the manipulation to position the amplifier is simplified.

Conclusion: We believe that this technique could be used in routine practice and that this method could be proposed for the entire range of nailing procedures.