Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Bone & Joint Open
Vol. 1, Issue 4 | Pages 55 - 63
7 Apr 2020
Terjesen T Horn J

Aims

When the present study was initiated, we changed the treatment for late-detected developmental dislocation of the hip (DDH) from several weeks of skin traction to markedly shorter traction time. The aim of this prospective study was to evaluate this change, with special emphasis on the rate of stable closed reduction according to patient age, the development of the acetabulum, and the outcome at skeletal maturity.

Methods

From 1996 to 2005, 49 children (52 hips) were treated for late-detected DDH. Their mean age was 13.3 months (3 to 33) at reduction. Prereduction skin traction was used for a mean of 11 days (0 to 27). Gentle closed reduction under general anaesthesia was attempted in all the hips. Concurrent pelvic osteotomy was not performed. The hips were evaluated at one, three and five years after reduction, at age eight to ten years, and at skeletal maturity. Mean age at the last follow-up was 15.7 years (13 to 21).


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 468 - 468
1 Nov 2011
Magetsari R Hilmy C van der Mei H Busscher H van Horn J
Full Access

The socio-economic conditions in many developing countries impede widespread general use of the assets of biomedical technology. In orthopedics this becomes evident from the large-scale, though illegal, reuse of osteosynthesis plates and screws. Scientific research into the issue of the safe reuse of osteosynthesis materials from a biological point of view has never been done. Therefore the aim of this study is to determine whether plates and screws after simple cleaning, applying means which are available in developing countries, are safe from a biological point of view. Cleaning methods evaluated include a toothbrush, water, detergent and bleach. X-ray photoelectron spectroscopy analysis of cleaned surfaces and water contact angle measurements indicate that application of these methods yield surface characteristics similar to those of new, sterilized plates. If desired, bleach can be applied without affecting the surface properties of the materials.

Subsequently, the reactivity of a mammalian monolayer in response to a used screw (ISO-10993-5) and endotoxin release (USP 27-NF 22) was evaluated, showing that all screws tested are non-cytotoxic with endotoxin release within the requirements of the FDA. This study shows that reuse is not necessarily unsafe from a biological point of view.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 305 - 305
1 May 2009
Hendriks H Ensing G Neut D van Horn J van der Mei H Busscher H
Full Access

Addition of antibiotics to the bone cement decreases the incidence of infection. However, the antibiotic is only partially released. Ultrasound may increase the antibiotic release and furthermore the effectiveness of the antibiotic might be enhanced by the so-called bio-acoustic effect.

The objective of this study was twofold. The first aim was to evaluate to what extent antibiotic release from bone cement could be increased by ultrasound. The second aim was to investigate the viability of bacteria when antibiotic release from bone cements was combined with ultrasound.

Cylindrical bone cement samples of Palacos R-G (loaded with gentamicin) and Copal (loaded with gentamicin and clindamycin) were insonated and antibiotic release was compared with uninsonated samples. In addition, identical samples were used in combination with cultures of bacteria derived from prosthesis-related infections. The viability of these bacteria was determined with and without ultrasound, using unloaded Palacos R as a control.

There was a trend of increased gentamicin release under influence of ultrasound. Clindamycin release from Copal was significantly increased. Ultrasound alone did not affect bacterial viability, but the application of ultrasound in combination with antibiotic-loaded bone cements reduced both planktonic and biofilm bacterial viability.

The release of antibiotics from bone cement was increased by the application of ultrasound. Antibiotic release in combination with ultrasound increases the antimicrobial efficacy against a variety of clinical isolates. The enhanced efficacy against bacteria in the biofilm mode of growth, especially against a gentamicin-resistant strain, is clinically important with regard to the treatment of infected joint prostheses. Ultrasound may also be applied in the early postoperative period to prevent infections, because planktonic bacteria present in the wound and wound area due to inevitable contamination during surgery can then be more effectively prevented from forming a biofilm.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 312 - 312
1 May 2009
Neut D Ensing G van Horn J van der Mei H Busscher H
Full Access

Copal bone cement loaded with gentamicin and clindamicin was developed recently as a response to the emerging occurrence of gentamicin-resistant strains in periprothetic infections. The objective of this study was to compare the in vitro antibiotic release and antimicrobial efficacy of gentamicin/clindamicin-loaded Copal bone cement and gentamicin-loaded Palacos R-G bone cement, as well as biofilm formation on these cements.

In order to determine antibiotic release, cement blocks were placed in phosphate buffer and aliquots were taken at designated times for measurement of antibiotic release. In addition, the bone cement discs were pressed on agar to study the effects of antibiotic release on bacterial growth. Biofilm formation on the different bone cements was also investigated after 1 and 7 days using plate counting and confocal laser scanning microscopy (CLSM). Experiments were done with a gentamicin-sensitive S. aureus and a gentamicin-resistant CNS.

Antibiotic release after 672 h from Copal bone cement was more extensive (65% of the clindamycin and 41% of the gentamicin incorporated) than from Palacos R-G (4% of the gentamicin incorporated). The higher antibiotic release from Copal resulted in a stronger and more prolonged inhibition of bacterial growth on agar. Plate counting and CLSM of biofilms grown on the bone cements showed that antibiotic release reduced bacterial viability, most notably close to the cement surface. Moreover, the gentamicin-sensitive S. aureus formed gentamicin-resistant small colony variants on Palacos R-G, and therefore, Copal was much more effective in decreasing biofilm formation than Palacos R-G.

Biofilm formation on bone cement could be more effectively reduced by incorporation of a second antibiotic, next to gentamicin. Antibiotic release from the cements had a stronger effect on bacteria close to the cement than on bacteria at the outer surface of the bio-film. Clinically, bone cement with two antibiotics may be more effective than cement loaded with only gentamicin. The clinical efficacy of antibiotic loaded bone cements in combination with systemic antibiotics can be explained because antibiotics released from cements kill predominantly the bacteria in the bottom of the biofilm, whereas systemic antibiotics can only deal with bacteria at the outer surface of the biofilm.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 248 - 248
1 Sep 2005
Ensing G Hendriks J Jongsma J Van Horn J Van der Mei H Busscher H
Full Access

Introduction: Local drug delivery yields higher gentamicin concentrations than can be safely achieved with systemic application. Unfortunately, both for beads as well as for bone cements, a sharp drop in release follows high initial gentamicin release. Aim of this study is to compare the effects of pulsed ultrasound on the release of gentamicin from antibiotic-loaded beads and bone cements. Mercury intrusion porosimetry is carried out to compare the pore size distribution in both materials before and after antibiotic release.

Materials and Methods: Ultrasound: Gentamicin release from three brands of gentamicin-loaded bone cement (CMW 1, Palamed G and Palacos R-G) and Septopal gentamicin-loaded beads was measured after 18 h of exposure in PBS to an ultrasonic field of 46.5 kHz in a 1:3 duty cycle with a peak intensity of 500 mW/cm2 at the sample position. Ultrasound experiments were performed for 18h in 9-fold on bone cement and in 6-fold on beads. Samples not exposed to ultrasound were used as controls. The gentamicin release was measured with fluorescence polarisation immunoassay. Gentamicin release from insonated and control groups was compared using a two-tailed Student’s t test for independent samples.

Mercury intrusion porosimetry: In order to mimic bone cement and beads after prolonged stay in the human body (i.e. after initial release of the loaded gentamicin) samples were immersed for four and two weeks, in PBS. Immersed and not-immersed samples were compared.

Results: Pulsed ultrasound significantly enhanced gentamicin release from gentamicin-loaded beads, whereas gentamicin release from the gentamicin-loaded bone cements was not significantly enhanced. Mercury intrusion porosimetry revealed a rise in pores between 0.1 and 0.01 um in beads after gentamicin release, while in bone cements no increase in the number of pores before and after antibiotic release was found.

Conclusions: Ultrasound increases gentamicin release from antibiotic-loaded acrylic beads by 15%. Development of pores coincides with increased gentamicin release by ultrasound for beads. Application of ultrasound could optimise usage of an (antibiotic) reservoir in local drug delivery systems to treat bone and soft tissue infections more effectively.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 251 - 251
1 Sep 2005
Knobben B Engelsma Y Neur D van der Mei H Busscher H van Horn J
Full Access

Introduction: One of the primary complications in total hip and knee arthroplasty is infection. One of the major risk factors for deep periprosthetic infection is wound infection. This alone is associated with a substantial morbidity-increase which, in turn, increases hospital admittance time and therefore adds significant costs to the healthcare system. The aim of this study is to determine whether contamination of instruments used during primary insertion of a prosthesis, can be considered an early indicator for the occurrence of prolonged wound discharge. Early antibiotic treatment could then prevent this and decrease hospital admittance time and costs to the health care system.

Material and Methods: During 121 procedures, swabs were taken from the first unused broach at the beginning and at the end of the procedure. Removed material from the bone (acetabulum and femur in the hip joint; femur and tibia in case of the knee joint) was tested for contamination as well. During 50 procedures a control swab was taken. The patients on the ward were also monitored to find out whether prolonged wound discharge occurred and to see after how many days the patients were discharged.

Results: In 46 cases (38%) at least one culture showed microbial growth. In the other 75, there was no growth at all. If one of the cultures is positive, there is a 52% risk of prolonged wound discharge. Ifall cultures are negative, this risk is reduced to 13% (Chi-square: PO.001). Patients with a positive peroperative culture have to remain in the hospital for an additional 2.4 days (T-test: P-0.001).

Conclusion: Peroperative culturing during primary insertion of a knee or hip prosthesis, provides a reliable tool to predict postoperative duration of wound discharge and hospital-admittance time.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 252 - 252
1 Sep 2005
Jutte P Rutgers S van Altena R van Horn J
Full Access

Introduction: Data on intralesional concentrations of modern anti-tuberculosis drugs isoniazid (H), rifampin (R) and pyrazinamid (Z) in tuberculous pleural effusions and psoas abscesses are scarce. Insight into drug penetration is important since subtherapeutic drug concentrations may result in the selection of a resistant bacterial population and lead to treatment failure.

Material and Methods: Intralesional concentrations were measured 2 hours after drug administration in 6 patients with pleural effusions, and 10 with psoas abscesses.

Results: Concentrations were variable. The same range was found for pleural effusions and psoas abscesses. Concentrations were below MIC values in none of 15 patients for H, in 2 of 13 for R, and in 8 of 9 for Z. Cmax:MIC ratio was always > 4 for H, in 4 of 13 for R, and in none of 9 for Z. In 5:8 patients receiving all 3 drugs both R and Z had Cmax:MIC ratios < 4, indicating subtherapeutic drug levels.

Conclusion: Intralesional drug concentrations of isoniazid (H), rifampin (R), and pyrazinamid (Z) were variable. The same range was found for pleural effusions and psoas abscesses. Cmax:MIC ratio for H was always sufficient, for R in most cases below the desired ratio, and for Z on average 10 times too low. In 5 of 8 patients receiving all 3 drugs, both R and Z had Cmax:MIC ratios below 4, indicating intralesional subtherapeutic drug levels for R and Z. This local monotherapy with H may result in the selection of a resistant bacterial population and lead to failure of treatment. Drainage as additional therapy seems indicated.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 271 - 271
1 Mar 2003
Heeg M De Ridder C Van Horn J
Full Access

Purpose: To assess the long-term outcome of Schanz subtrochanteric abduction osteotomy (SO) in patients with long-standing dislocation of the hip

Patients and methods: Between 1962–1981, 11 patients were treated with a SO. Nine patients, in whom 16 SO procedures were performed, were available for follow-up. Seven hips had had failed surgery in infancy, 9 hips had not been operated on previously. The average age at the time of SO was 17.8 (12–29) years. The degree of dislocation at the time of SO was classified according to Eftekhar type B: subluxation; (4 hips); type C: dislocation with neo-acetabulum, (8 hips) patients, and type D: high dislocation, no neo-acetabulum (4 hips). The indications to perform SO were fatigue and a painful lurch in 14 hips and a flexion/adduction contracture with pain in 2 hips. Post-operatively, patients were immobilised in suspended traction for 6–8 weeks, followed by progressive weight-bearing. Follow-up averaged 21 (14–37) years. Follow-up included the Harris-Hip score and ADL-score (Barthel-index); working status, sexual problems, ROM, hip/knee instability and radiographic examination.

Results: Ten secondary surgical procedures were performed at an interval of 6–19 years following SO: shelf procedure ( 5); Epiphyseodesis (3) and total hip (2). The shelf procedures were performed for residual hip pain, at an average of 12 years. The total hips were performed after 17 and 19 years following SO. Both have failed and had complicated hip-revisions. ROM was severely restricted in 4 patients. The mean Harris hips score was 76 ( 27–97). One of six bilateral cases and 2 of 4 unilateral cases had poor functional results. All patients had unlimited ADL activities; 7 patients regularly participated in cycling and swimming. Three female patients experienced minor sexual problems, due to limited abduction. Four patients had 400 excessive valgus at the knee, without clinical or radiographic symptoms. Leg-length discrepancy varied from 0–3 cm.

Conclusion: 1. The results of SO in patients with Eftekhar C/D were surprisingly fair, and poor in type B, subluxation.