Fourteen hips with osteoarthritis had femoral head blood flow measured with laser Doppler flowmeter while undergoing during total hip replacement through a modified lateral approach. Mean age sixty-five years (48–77); eight males &
six females. Two measurements were taken within the femoral head one after anterior hip dislocation and one after simulated notching of the femoral neck. All hips had a significant decrease in blood flow with a median percentage decrease of 76% (range 4.4–90.4). During surface arthroplasty of the hip, notching of the femoral neck may not only mechanically weaken the bone but also put the femoral head at risk of osteonecrosis. To evaluate femoral head blood supply in patients with osteoarthrtis of the hip undergoing simulated notching of the femoral neck during total hip replacement and its potential implications in hip resurfacing. During surface arthroplasty of the hip, notching of the femoral neck may not only mechanically weaken the femoral neck but also put the femoral head at risk of osteonecrosis and subsequent femoral loosening. It would appear that the retinacular vessels (extraosseous blood supply) are as important in the arthritic femoral head as they are in the nonarthritic state, contradicting the notion that arthritic femoral heads in humans rely mainly on an intraosseous blood supply. Fourteen hips with a diagnosis of degenerative arthritis had femoral head blood flow measured with laser Doppler flowmeter while undergoing during total hip replacement through a modified lateral approach. With the femoral head exposed and leg in neutral position, a 3.5mm drill hole was made into the anterior lateral quadrant and the fiber optic probe of the laser Doppler flowmeter (Moor Instruments, Wilmington Delaware, 20mW laser, wavelength 780nm) was inserted. Mean age was sixty-five years (48–77). Eight males and six females. Two measurements were taken one after anterior hip dislocation and one after simulated notching of the femoral neck. All but four hips had a significant decrease of more than 50% in blood flow after neck notching with a median percentage change of 76% (range 4.4–90.4), p<
0.001.