Vol. 94-B, Issue SUPP_XXXVII | Pages 13 - 13
1 Sep 2012
Panteli M Mcroberts J Habeeb S Porteous M
Full Access

Background

With the recent trend towards enhanced care in joint replacement, it has become increasingly important to identify and address the areas that affect early patient length of stay, while ensuring that practice remains safe. As part of an enhanced care program we conducted two prospective studies of factors delaying discharge following hip replacement in 2006 and 2010.

Materials and Methods

In each limb of the study data was collected prospectively daily, by an independent observer, on 100 consecutive primary cemented total hip replacements. Reasons for delay to the discharge and variation from the patient pathway were identified and addressed.