OBJECTIVES: In recent years the incidence of proximal humerus fractures increased strongly. The optimal treatment of displaced, unstable fractures is still controversial. One of the major problem seen in previous treatment options was implant failure with secondary dislocation, pseudarthrosis and AVN. New angular stable implants promise a stronger anchorage and allow early functional aftertreatment, especially in osteopenic bone. Aim of this prospective case-series was to assess complication risks and functional outcome after ORIF with an angular stable form plate
DESIGN: Prospective case-series
SETTING: Multicenter study in 8 European Trauma Units
PATIENTS: 157 patients were treated for 158 displaced proximal humerus fractures
INTERVENTION: ORIF with a PHILOS™ plate.
RESULTS: According to the AO/ASIF classification 25%, 61% and 37% were classified as type A, B and C, respectively. One year follow-up rate was 84%, whereupon 6 patients had died in the mean time and 18 were lost to follow-up. Overall 71 complications were observed in 53 patients and led to 39 unplanned re-operations, whereupon most frequent were primary screw perforations (n=22), secondary screw perforations (n=13)–mostly with secondary impaction (n=11), and AVN (n=8). Increasing age and severity of fractures influenced the occurrence of complications, since the risk to obtain a complication was doubled in patients over 60 years compared to younger (Relative Risk 1.9; Fischer’s Exact, p=0.022) as well as in AO/ASIF B- and C-fractures compared to A-fractures (Relative Risk=1.8; Fischer’s Exact, p=0.05). Risks for complications related to the implant, surgical technique or fracture and bone were 9%, 20% and 13%, respectively. Within one year all fractures healed and 5 secondary dislocations were observed. The mean (SD) Constant score of the injured shoulder improved during follow-up period to 72 points (15.2) at 12 months follow-up, when 87% (16.6%) of the contralateral shoulder was reached. Across all follow-up examinations the Constant score in relation to the contralateral shoulder impaired with increasing severity of the fracture (ANOVA, p=0.006). The mean (SD) DASH score after one year was with 16 points (21.1) worser (T-test, p<
0.001) than before the accident [5.2 (11.4)].
CONCLUSIONS: Fixation with a Philos plate provides high stability to preserve achieved reduction, which benefits the good functional outcome. However surgical technique related complication risks are high, particularly due to screw perforations into the joint. Augmented awareness and improvement of surgical technique should reduce these risks. Complex fracture types and higher age increases the risk to sustain complications, where as only severity of fractures impairs the functional outcome.