Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 19 - 27
1 Jan 2024
Tang H Guo S Ma Z Wang S Zhou Y

Aims

The aim of this study was to evaluate the reliability and validity of a patient-specific algorithm which we developed for predicting changes in sagittal pelvic tilt after total hip arthroplasty (THA).

Methods

This retrospective study included 143 patients who underwent 171 THAs between April 2019 and October 2020 and had full-body lateral radiographs preoperatively and at one year postoperatively. We measured the pelvic incidence (PI), the sagittal vertical axis (SVA), pelvic tilt, sacral slope (SS), lumbar lordosis (LL), and thoracic kyphosis to classify patients into types A, B1, B2, B3, and C. The change of pelvic tilt was predicted according to the normal range of SVA (0 mm to 50 mm) for types A, B1, B2, and B3, and based on the absolute value of one-third of the PI-LL mismatch for type C patients. The reliability of the classification of the patients and the prediction of the change of pelvic tilt were assessed using kappa values and intraclass correlation coefficients (ICCs), respectively. Validity was assessed using the overall mean error and mean absolute error (MAE) for the prediction of the change of pelvic tilt.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 70 - 70
1 Feb 2020
Huang Y Zhou Y Yang D Tang H Shao H Guo S
Full Access

Aims

Only a small number of studies exist that report the results of EBM-produced porous coated trabecular titanium cups in primary total hip arthroplasty (THA). This study aims to investigate the patient satisfaction level, clinical function and radiographic outcomes of the patients who underwent THA using an EBM-produced porous coated titanium cup.

Patients and Methods

A total of 32 patients who underwent primary THA with using an EBM-produced porous coated titanium cup from five hospitals between May and December, 2012 were retrospectively reviewed. Five patients were lost prior to the minimum 6-year follow-up. Clinical and radiographic outcomes were analyzed with an average follow-up of 81.48 (range: 77.00–87.00) months.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 19 - 19
1 Apr 2019
Zhou Y Huang Y Tang H Guo S Yang D Zhou B
Full Access

Background

Failed ingrowth and subsequent separation of revision acetabular components from the inferior hemi-pelvis constitutes a primary mode of failure in revision total hip arthroplasty (THA). Few studies have highlighted other techniques than multiple screws and an ischial flange or hook of cages to reinforce the ischiopubic fixation of the acetabular components, nor did any authors report the use of porous metal augments in the ischium and/or pubis to reinforce ischiopubic fixation of the acetabular cup. The aims of this study were to introduce the concept of extended ischiopubic fixation into the ischium and/or pubis during revision total hip arthroplasty [Fig. 2], and to determine the early clinical outcomes and the radiographic outcomes of hips revised with inferior extended fixation.

Methods

Patients who underwent revision THA utilizing the surgical technique of extended ischiopubic fixation with porous metal augments secured in the ischium and/or pubis in a single institution from 2014 to 2016 were reviewed. 16 patients were included based on the criteria of minimum 24 months clinical and radiographic follow-up. No patients were lost to follow-up. The median duration of follow-up for the overall population was 37.43 months. The patients' clinical results were assessed using the Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index and Short form (SF)-12 score and satisfaction level based on a scale with five levels at each office visit. All inpatient and outpatient records were examined for complications, including infection, intraoperative fracture, dislocation, postoperative nerve palsy, hematoma, wound complication and/or any subsequent reoperation(s). The vertical and horizontal distances of the center of rotation to the anatomic femoral head and the inclination and anteversion angle of the cup were measured on the preoperative and postoperative radiographs. All the postoperative plain radiographs were reviewed to assess the stability of the components.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 20 - 20
1 Apr 2019
Tang H Zhou Y Zhou B Huang Y Guo S
Full Access

Aims

Severe, superior acetabular bone defects are one of the most challenging aspects to revision total hip arthroplasty (THA). We propose a new concept of “superior extended fixation” as fixation extending superiorly 2 cm beyond the original acetabulum rim with porous metal augments, which is further classified into intracavitary and extracavitary fixation. We hypothesized that this new concept would improve the radiographic and clinical outcomes in patients with massive superior acetabular bone defects.

Patients and Methods

Twenty eight revision THA patients were retrospectively reviewed who underwent reconstruction with the concept of superior extended fixation from 2014 to 2016 in our hospital. Patients were assessed using the Harris Hip Score (HHS) and the Western Ontario and McMaster Universities Osteoarthritis Index score (WOMAC). In addition, radiographs were assessed and patient reported satisfaction was collected.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 64 - 64
1 Jan 2016
Tang H Zhou Y Yang D Guo S Chen H Wang Z
Full Access

Background

Soft tissue tension and intra-articular pressure distribution plays a crucial role in postoperative function and survivorship of TKA prosthesis. Although posterior stabilized (PS) and cruciate retaining (CR) knees have both been successful in relieving pain and restore function, it is reported that the joint gaps were significantly distinct between the two designs during flexion. The aim of this study is to find out what is the difference in intra-articular pressure distribution between PS and CR knees.

Methods

We prospectively included 45 consecutive patients (50 knees) scheduled for total knee arthroplasty between August, 2013 and April, 2014 in our hospital. 23 patients (25 osteoarthritic knees) received a Genesis II CR TKA (Smith & Nephew, Memphis, USA), and the other 22 patients (25 osteoarthritic knees) received Genesis II PS TKA (Smith & Nephew, Memphis, USA). During operation, after the bone osteotomy and soft tissue balance were completed, we measured and compared the intra-articular pressure distribution at 0°, 30°, 45°, 60°, 90°, and 120° flexion with a previously validated “Wireless Force Measurement System (WFMS)”. Joint gaps were measured at extension and 90° flexion. The soft tissue was not considered balanced until the medial and lateral joint gap difference ≤ 2mm at extension and 90° flexion. There are no significant differences in age, gender, BMI, varus angle and flexion deformity, and preoperative range of motion between the two groups. The medial-lateral pressure distribution and total pressure were compared at different angles between CR and PS knees.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 152 - 152
1 Jan 2016
Tang H Zhou Y Yang D Guo S Tang J Liu J
Full Access

Background

The development of T-smart tomosynthesis has greatly improved the imaging quality of THA by reducing the peri-implant artifacts. In order to find out whether these improvements could lead to diagnostic advantages on stability of cementless THA arthroplasty components, we conducted a diagnostic research by comparing T-smart tomosynthesis, X-ray, and computed tomography.

Methods

We retrospectively included 48 patients who undergone THA revisions in our center between Aug, 2013 and Mar, 2014. For patients with hybrid fixation as their primary prosthesis, the femoral or acetabular components with cement fixation were excluded. There were 41 cementless femoral stems and 35 cementless acetabular cups remained for evaluation. All patients took anterior-posterior and lateral view x-ray examination, anterior-posterior T-smart tomosynthesis scan, and computed tomography before revision surgery. As the gold standard, intraoperative pull-out tests and twisting tests were done for every patient to examine the stability of all implants. 7 orthopedic surgeons evaluated the preoperative images independently, who were divided into the senior group (3 doctors with 6∼13 years’ clinical experience) and the junior group (4 doctors with 2∼4 years’ clinical experience). The x-rays were evaluated first, followed by computed tomography 4 weeks later, and after another 4 weeks’ interval the T-smart tomosynthesis were assessed. All doctors used the same criteria for diagnosis. Diagnostic accuracy for each imaging examination was calculated by comparing with the results of intraoperative tests. The diagnostic accuracy, kappa values between 3 imaging techniques were calculated, and chi-square tests were conducted to examine the difference between the senior and junior groups for each technique.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 331 - 331
1 Dec 2013
Guo S Baskaradas A Holloway I
Full Access

Introduction

Reconstructing acetabular defects in revision hip arthroplasty can be challenging. Small, contained defects can be successfully reconstructed with porous-coated cups without bone grafts. With larger uncontained defects, a cementless cup even with screws, will not engage with sufficient host bone to provide enough stability.

Porous titanium augments were originally designed to be used with cementless porous titanium cups, and there is a scarcity of literature on their usage in cemented cups with bone grafting.

Methods

We retrospectively reviewed five hips (four patients – 3 women, 1 man; mean age 65 years) in which we reconstructed the acetabulum with a titanium augment (Biomet, IN, USA) as a support for impaction bone grafting and cemented acetabular cups (Figure 1). All defects were classified according to Paprosky classification. Radiographic signs of osseointegration were graded according to Moore grading. Quality of life was measured with the Oxford Hip Score.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 425 - 425
1 Nov 2011
Liu Q Zhou Y Xu H Tang J Guo S Tang Q
Full Access

Prosthetic reconstruction of high-riding hips is technically demanding. Insufficient bony coverage and osteopenic bone stock frequently necessitate transacetabular screw fixation to augment primary stability of the metal shell. We sought to determine the validity of the previously reported quadrant system, and if needed, to define a specialized safe zone for augmentation of screw fixation to avoid vascular injuries in acetabular cup reconstruction for high-riding hips.

Volumetric data from computed tomography enhancement scanning and CT angiography of eighteen hips (twelve patients) were obtained and input into a three-dimensional image-processing software. Bony and vascular structures were reconstructed three-dimensionally; we virtually reconstructed a cup in the original acetabulum and dynamically simulated transacetabular screw fixation. We mapped the hemispheric cup into several areas and, for each, measured the distance between the virtual screw and the blood vessel.

We found that the rotating centers of the cups shifted more anterior-inferiorly in high-riding hips than those in ordinary cases, and thus the safe zone shifted as well. Screw fixation guided by the quadrant system frequently injured the obturator blood vessels in high-riding hips. We then defined a specialized safe zone for transacetabular screw fixation for high-riding hips.

We conclude that the quadrant system can be misleading and of less value in guiding screw insertion to augment metal shells for high-riding hips. A new safe zone specific to high-riding hips should be used to guide transacetabular screw fixation in these cases.