Advertisement for orthosearch.org.uk
Results 1 - 20 of 35
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 22 - 22
2 May 2024
Logishetty K Whitwell D Palmer A Gundle R Gibbons M Taylor A Kendrick B
Full Access

There is a paucity of data available for the use of Total Femoral Arthroplasty (TFA) for joint reconstruction in the non-oncological setting. The aim of this study was to evaluate TFA outcomes with minimum 5-year follow-up.

This was a retrospective database study of TFAs performed at a UK tertiary referral revision arthroplasty unit. Inclusion criteria were patients undergoing TFA for non-oncological indications. We report demographics, indications for TFA, implant survivorship, clinical outcomes, and indications for re-operation.

A total of 39 TFAs were performed in 38 patients between 2015–2018 (median age 68 years, IQR 17, range 46–86), with 5.3 years’ (IQR 1.2, 4.1–18.8) follow-up; 3 patients had died. The most common indication (30/39, 77%) for TFA was periprosthetic joint infection (PJI) or fracture-related infection (FRI); and 23/39 (59%) had a prior periprosthetic fracture (PPF). TFA was performed with dual-mobility or constrained cups in 31/39 (79%) patients. Within the cohort, 12 TFAs (31%) required subsequent revision surgery: infection (7 TFAs, 18%) and instability (5 TFAs, 13%) were the most common indications. 90% of patients were ambulatory post-TFA; 2 patients required disarticulation due to recurrent PJI. While 31/39 (79%) were infection free at last follow-up, the remainder required long-term suppressive antibiotics.

This is the largest series of TFA for non-oncological indications. Though TFA has inherent risks of instability and infection, most patients are ambulant after surgery. Patients should be counselled on the risk of life-long antibiotics, or disarticulation when TFA fails.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 40 - 40
1 May 2019
Vanhegan I Martin A Gundle R Taylor A Kendrick B
Full Access

Introduction

We are a high-volume arthroplasty unit performing over 800 primary THRs annually at an approximate reimbursement of £6.5 million to the Trust. 70% are hybrid and we have been using the Taperfit - Trinity combination (Corin, Cirencester) since March 2016. We aimed to investigate the potential cost-savings and clinical benefits of instrument rationalisation using this system following GIRFT principles.

Methods

Taperfit (ODEP 10A) is a polished, collarless, double tapered stem available in multiple sizes/offsets. Trinity is a hemispherical porous titanium cementless shell. A prospective audit of implant size was performed for the first 50 cases. Based on these findings, instruments were reduced to a single tray per component based on predicted size, named ‘Corin Hip for the Osteoarthritic Patient’ (CHOP). A further re-audit was performed to confirm correct tray constituent sizes. Financial data were calculated using known TSSU costs of approximately £50 per tray.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 56 - 56
1 Dec 2016
Kendrick B Grammatopoulos G Philpott A Pandit H Atkins B Bolduc M Alvand A Athanasou N McNally M McLardy-Smith P Murray D Gundle R Taylor A
Full Access

Aim

Advocates of Debridement-Antibiotics-and-Implant-Retention (DAIR) in hip peri-prosthetic joint infection (PJI) argue that a procedure not disturbing a sound prosthesis-bone interface is likely to lead to better survival and functional outcome compared to revision. However, no evidence supports this. This case-control study's aims were to compare outcome of DAIRs for infected 1° total hip arthroplasty (THA) with outcomes following 1° THA and 2-stage revisions of infected 1° THAs.

Method

We retrospectively reviewed all DAIRs, performed for confirmed infected 1° THR (DAIR-Group, n=80), in our unit between 1997–2013. Data recorded included patient demographics, medical history, type of surgery and organism identified. Outcome measures included complications, mortality, implant survivorship and functional outcome using the Oxford Hip Score (OHS). Outcome was compared with 2 control groups matched for gender and age; a cohort of 1° THA (1°-THA-Group, n=120) and a cohort of 2-stage revisions for infection (2-Stage-Revision-Group, n=66).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 4 - 4
1 Dec 2016
Alvand A Grammatopoulos G de Vos F Scarborough M Athanasou N Kendrick B Price A Gundle R Whitwell D Jackson W Taylor A Gibbons M
Full Access

Introduction

The burden of peri-prosthetic joint infection (PJI) following hip and knee surgery is increasing. Endoprosthetic replacement (EPR) is an option for management of massive bone loss resulting from infection around failed lower limb implants.

Aims

To determine clinical outcome of EPRs for treatment of PJI around the hip and knee joint.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 49 - 49
1 Jun 2016
Spiegelberg B Kendrick B Taylor A Stubbs D McLardy-Smith P Gundle R
Full Access

Introduction

Native hip joint infection can result in hip arthrosis as a complication requiring the need for subsequent arthroplasty. There is little evidence to support single or staged THA. We present the results of patients who have undergone total hip arthroplasty (THA) following hip joint sepsis in our institution.

Methods

Patients receiving a THA following previous hip joint sepsis between 2003 and 2015 were identified from the operative records database. Further clinical information was collected from the medical records, including timing of infection and surgery, as well as culture results. Functional outcome (Oxford Hip Score, OHS) and patient satisfaction scores (PSS) were recorded.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 52 - 52
1 Jun 2016
Grammatopoulos G Kendrick B Glyn-Jones S McLardy-Smith P Taylor A Gundle R
Full Access

Introduction

The value of Debridement-Antibiotics-and-Implant-Retention (DAIR) in prosthetic-joint-infection (PJI) is still a matter of debate as most studies to-date are underpowered with variable end-points. In our, tertiary referral, bone infection unit we consider DAIR to be a suitable option in all PJIs with soundly fixed prostheses, despite chronicity. The aims of this study were to define the long-term outcome following DAIR in hip PJI and identify factors that influence it.

Methods

This is a retrospective consecutive case series of DAIRs performed between 1997 and 2013. Only infected cases confirmed by established criteria were included. Data recorded included patient demographics, medical history (ASA grade, Charlson and KLICC scores), type of surgery performed (DAIR or DAIR + exchange of modular components) and organism grown. Outcome measures included complications, implant survivorship and functional outcome (Oxford Hip Score, OHS).


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 72 - 72
1 Dec 2015
Grammatopoulos G Kendrick B Athanasou N Byren I Atkins B Mcnally M Mclardy-Smith P Gundle R Taylor A
Full Access

Debridement, antibiotics and implant retention (DAIR) is a surgical option in the treatment of prosthetic joint infection (PJI). It is thought to be most appropriate in the treatment of early (≤6 weeks post-op) PJI. Most studies to-date reporting on DAIRs in hip PJI have been underpowered by reporting on small cohorts (n= <45), or report on registry data with associated biases and limitations. In our, tertiary referral, bone infection unit we consider DAIR to be a suitable option in all cases of PJI with a soundly fixed prosthesis, with early or late presentation, especially in patients who are too elderly or infirm to undergo major surgery.

Aim: To define the 10-year outcome following DAIR in hip PJI and identify factors that influence it.

We retrospectively reviewed all DAIRs performed in our unit between 1997 and 2013 for hip PJI. Only infected cases confirmed by histological and microbiological criteria were included. Data recorded included patient demographics and medical history, type of surgery performed (DAIR or DAIR + exchange of modular components), organism identified and type/duration of antibiotic treatment. Outcome measures included complications, mortality rate, implant survivorship and functional outcome.

121 DAIRs were identified with mean age of 71 years (range: 33–97). 67% followed an index procedure of 1° arthroplasty. 53% included exchange of modular components. 60% of DAIRs were for early onset PJI. Isolated staphylococcus was present in 50% of cases and 25% had polymicrobial infection. At follow-up (mean:7 years, range: 0.3 – 18), 83 patients were alive; 5- and 10- year mortality rates were 15% and 35% respectively. 45% had a complication (persistence of infection: 27%, dislocation: 10%) and 40% required further surgery. Twenty hips have been revised to-date (17%). Performing a DAIR and not exchanging the modular components was associated with an almost 3× risk (risk ratio: 2.9) of subsequent implant failure (p=0.04). 10-yr implant survivorship was 80% (95%CI: 70 – 90%). Improved 10-year implant survivorship was associated with DAIR performed for early PJI (85% Vs 68%, p=0.04). Functional outcome will be discussed.

DAIR is a particularly valuable option in the treatment of hip PJI, especially in the early post-operative period. Whenever possible, exchange of modular implants should be undertaken, however DAIRs are associated with increased morbidity even in early PJI. Factors that predict success of DAIR in late PJI need to be identified.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 19 - 19
1 Jan 2013
Thomas G Batra R Kiran A Palmer A Gibbons C Gundle R Hart D Spector T Gill H Javaid M Carr A Arden N Glyn-Jones S
Full Access

Introduction

Subtle deformities of the acetabulum and proximal femur are recognised as biomechanical risk factors for the development of hip osteoarthritis (OA) as well as a cause of hip and groin pain. We undertook this study to examine relationships between a number of morphological measurements of the acetabulum and proximal femur and the hip pain in a 20-year longitudinal study.

Methods

In 1989 women of 45–64 years of age were recruited. Each had an AP-Pelvis radiograph at Year-2. These radiographs were analysed using a validated programme for measuring morphology. All morphological measurements were read blinded to outcome. At year 3 all participants were asked whether they experienced hip pain (side specific). This was repeated at visits up to and including 20-years. Logistic regression analysis (with robust standard errors and clustering by subject identifier) was performed using hip pain as a binary outcome. The model adjusted for baseline age, BMI and joint space and included only participants who were pain free on initial questioning.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 247 - 247
1 Sep 2012
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R Mclardy-Smith P Gill H Murray D
Full Access

Introduction

Since the introduction of 3rd generation Metal-on-Metal-Hip-Resurfacing-Arthroplasty (MoMHRA), thousands of such prostheses have been implanted worldwide in younger patients with end-stage hip osteoarthritis. However, no independent centre has reported their medium-to-long term outcome. The aim of this study is to report the ten year survival and outcome of the Birmingham Hip Resurfacing (BHR), the most commonly used MoMHRA worldwide.

Methods

Since 1999, 648 BHRs were implanted in 555 patients, the majority of which were male (326). The mean age at surgery was 52.1years (range: 17–82), with primary OA as most common indication (85%). Mean follow up was 7.1years (range: 1–11). The Oxford Hip Score (OHS) and UCLA questionnaires were sent to all patients. Implant survival was established, with revision as the end point. Sub-analysis was performed by gender, femoral component size (small: <45mm, standard: 46–52, large: >53mm) and age at surgery (young:<50yrs, old:>50yrs).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 579 - 579
1 Sep 2012
Grammatopoulos G Pandit H Backer K Gundle R Mclardy-Smith P Desmet K Murray D Gill H
Full Access

INTRODUCTION

Femoral neck narrowing (NN) following Metal-on-Metal Hip Resurfacing Arthroplasty (MoMHRA) is a well-recognised clinical phenomenon. The incidence of resurfaced hips with NN > 10% is reported to be up to 27%. Its pathogenesis is thought to be multi-factorial secondary to stress shielding, impingement, osteolysis secondary to wear/ion particles and as a result of reduced vascularity and pressure effect on cancellous bone secondary to the presence of a soft-tissue mass around the resurfaced hip. Recognised risk factors for its development include: female gender and the presence of a pseudotumour. Serum Chromium (Cr) and Cobalt (Co) are recognised surrogate markers of in-vivo wear of MoMHRA. The aims of this study were to establish whether NN is associated with increased wear.

METHODS

A cohort of 214 patients with unilateral MoMHRA (139M: 75F) was included in this study. Primary osteoarthritis was the diagnosis leading to surgery for the majority of patients (208). The average age at surgery was 54.1 years old (13–73). Six different implants were used; BHR (116), Conserve plus (92), Recap (2), ASR (2), Adept (1) and Cormet (1). The average femoral component size was 49.2mm (range: 38–59). The average follow up was 4.3 years (range: 2–10). Patients were subdivided into 3 groups as per implant size. Small size component group had implants <45mm, average size group had components 45–51mm and large component size group had components >51mm.

All patients had Prosthesis-Junction-Ratio (PJR) measured from postoperative (PJRpost) and at latest follow up (PJRfollow) radiographs. Measurements were made using the method described by Lilikakis1.

Metal ion levels (Cr/Co) were measured at last follow-up for all patients. Cr level >5.1g/ml and Co levels >4.4 g/ml were considered high2 and patients with such levels formed the high ion group.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 456 - 456
1 Sep 2012
Grammatopoulos G Pandit H Mellon S Glyn-Jones S Gundle R Mclardy-Smith P Murray D Gill H
Full Access

INTRODUCTION

Studies have suggested that there is a reduction in head-neck-ratio (HNR) associated with MoMHRA. A reduction in HNR at operation would decrease range of movement and increase impingement risk. Impingement could lead to 20 edge loading, increasing wear. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Although acetabular component orientation has been shown to contribute to wear and PT development, the role of a decrease in HNR has only been highlighted in PT development. This study aimed to measure changes in HNR that occur at resurfacing and determine any gender- and component size-specific differences. In addition it aimed to determine whether changes in HNR could be associated with increased wear.

METHODS

84 patients (56M: 28F) with unilateral MoMHRA were included. The mean age at surgery was 57 years. The mean femoral component was 49mm. Components were considered small if <45mm, average if between 45–50mm and large if >50mm. Three designs were implanted; BHR, C+ and Recap. The average follow up was 4 years. All patients had Cr/Co levels measured at follow up. Patients were considered to have high ions if Cr and Co levels were 5.1ppb and 4.4ppb respectively.

Pre-operative HNR (HNRpre) and the post-operative HNR (HNRpost) were made from the respective pelvic radiographs. Assuming a 2mm thick cartilage layer, the HNR based on the diameter of the articular cartilage pre-operatively (HNRart) was calculated.

The immediate changes in HNR as a result of the operation were expressed relative to articular HNR pre-op:

HNRartpost=HNRpost–HNRart


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 546 - 546
1 Nov 2011
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R McLardy-Smith P Murray D Gill H
Full Access

Introduction: Metal-on-metal-hip-resurfacing-arthroplasty (MoMHRA) has been associated with the development of inflammatory pseudotumours(IP), especially in females. IPs have been linked to wear debris, which can be related to metal-ion blood levels. Acetabular component position has been shown to influence wear. We have identified an optimum component orientation minimising IP risk around an inclination/anteversion of 40°/20°±10°. Our aim was to see if this optimal position results in lower metal ions and to identify the boundary of an optimal placement zone for low wear.

Methods: A cohort of 104 patients(60M:44F) with unilateral MoMHRA was studied. Blood tests were obtained at a mean follow up of 3.9 years and serum Co/Cr levels were measured(ICPMS). High metal ion concentrations were defined as Co> 4.1ppb and Cr> 5.2ppb. Radiographic cup inclination/anteversion were measured using EBRA. The differences in ion levels between different orientation zones were investigated. Three orientation zones were defined centered on 40°/20°: Z1-within ±5°, Z2-outside ±5°/within ±10° and Z3-within ±10°.

Results: There was a wide range of cup placements. Females had significantly (p< 0.001) smaller components(mean:51, 44–60) than males(mean: 56, 52–64). Cr levels, but not Co, were higher in females(p=0.002) and those with small femoral components(< 50mm, p =0.03). Patients with cups within Z1 (n=13) had significantly lower Co(p=0.005) and Cr(p=0.001). Males with cups within Z3(n=27) had lower ion levels in comparison to those outside, which were significantly lower for Co(p=0.049) but not Cr(p=0.084). Females had similar ion levels within and out of Z3(Cr/Co: p=0.83/0.84). Co levels were significantly lower in Z1(n=13) in comparison to Z2(n=33)(p=0.048) but Cr levels were not different (p=0.06).

Discussion: MoMHRA cups placed within ±5° of the optimum(40°/20°) had significantly lower metal ions indicating lower wear within this narrow zone. This safe zone, could extend to ±10° for males only. The narrower safe zone coupled with smaller components implanted are possible factors contributing to the increased IP incidence seen in females.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 547 - 547
1 Nov 2011
Thomas G Simpson D Taylor A Whitwell D Gibbons C Gundle R Mclardy-smith P Gill H Glyn-jones S Murray D
Full Access

Introduction: The use of highly cross-linked polyethylene (HXLPE) is now commonplace for total hip arthroplasty, however there is no long-term data to support its use. Hip simulator studies suggest that the wear rate of some types of HXLPE is ten times less than conventional polyethylene (UHMWPE). The outcomes of hip simulator studies are not always reproduced in vivo and there is some evidence that HXLPE wear may increase between 5 and 7 years.

Method: A prospective double blind randomised control trial was conducted using Radiostereometric Analysis (RSA). Fifty-four subjects were randomised to receive hip replacements with either UHMWPE liners or HXLPE liners. All subjects received a cemented CPT stem and uncemented Trilogy acetabular component (Zimmer, Warsaw, IN, USA). The 3D penetration of the head into the socket was determined to a minimum of 7 years.

Results: The total liner penetration was significantly different at 7 years (p=0.005) with values of 0.33 mm (SE 0.05 mm) for the HXLPE group and 0.55 mm (SE 0.05 mm) for the UHMWPE group. The steady state wear rate from 1 year onwards was significantly lower for HXLPE (0.005 mm/yr, SE 0.007 mm/yr) than for UHMWPE (0.037 mm/yr, SE 0.009 mm/yr) (p=0.007). The direction of wear was supero-lateral.

Discussion: We have previously demonstrated that the penetration in the first year is creep-dominated, from one year onwards the majority of penetration is probably due to wear. This study confirms the predictions from hip simulator studies which suggest that the wear rate of this HXLPE approaches that of metal-on-metal and ceramic-on-ceramic articulations. HXLPE may have the potential to reduce the need of revision surgery, due to wear debris induced osteolysis. It may also enable surgeons to use larger couples, thus reducing the risk of impingement and dislocation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 546 - 546
1 Nov 2011
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R McLardy-Smith P Gill H Murray D
Full Access

Introduction: Metal on metal hip resurfacing arthroplasty(MoMHRA) is an alternative option to THR in the treatment of young adults with OA. A recognised MoMHRA complication is the development of an inflammatory pseudotumour(IP). Diagnosis is made with the aid of US and/or MRI. To-date, no radiographic indication of the presence of IP has been identified. Neck thinning is a recognised phenomenon in MoMHRA hips not associated with any adverse clinical events. Its pathogenesis is considered multi-factorial. Our aim was to establish whether excessive neck narrowing is associated with the presence of a pseudotumour.

Methods: Twenty-seven hips (26 patients) with IP confirmed clinically, radiologically, intra-operatively and histologically were matched for sex, age, pre-operative diagnosis, component size and follow-up with an asymptomatic MoMHRA cohort (Control n=60). For all patients, prosthesis-neck-ratio(PNR) was measured on plain AP pelvic radiographs post-operatively and at follow-up as previously described and validated.

Results: All IP patients (4M:23F) and all (12M:48F) but two controls had a posterior approach at the time of MoMHRA. Post-operatively, there was no difference in the PNR between the two groups (p=0.19). At an average follow up of 3.5 years (range:0.7–8.3), IP patients(mean 1.26, 1.10–1.79) had a significantly higher (p< 0.0001) PNR in comparison to their controls(mean 1.14, 1.03–1.35). Greater neck narrowing occurred in both genders. IP necks had narrowed by an average of 8% (range:3–23). The degree of neck narrowing was correlated with length of survival of implant (p=0.001).

Discussion: This study shows a strong association between IP and neck narrowing. Processes such as impingement and increased wear are considered to be involved in the pathogenesis of both IP and neck narrowing. Furthermore, the presence of an IP, could lead to altered vascularity via a mass effect and further contribute to neck narrowing. Neck narrowing in symptomatic MOMHRA patients should alert surgeons of the possible presence of IP.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 298 - 298
1 Jul 2011
Glyn-Jones S Pandit H Doll H McLardy-Smith P Gundle R Gibbons M Athanasou N Ostlere S Whitwell D Taylor A Gill R Murray D
Full Access

Metal on metal hip resurfacing (MMHR) is a popular procedure for the treatment of osteoarthritis in young patients. Several centres have observed masses, arising from around these devices, we call these inflammatory pseudotumours. They are locally invasive and may cause massive soft tissue destruction. The aim of this study was to determine the incidence and risk factors for pseudotumours that are serious enough to require revision surgery.

In out unit, 1,419 MMHRs were performed between June 1999 and November 2008. All revisions were identified, including all cases revised for pseudotumour. Pseudotumour diagnosis was made by histological examination of samples from revision. A Kaplan-Meier survival analysis was performed, Cox regression analysis was used to estimate the independent effects of different factors.

The revision rate for pseudotumour increased with time and was 4% (95% CI: 2.2% to 5.8%) at eight years. Female gender was a strong risk factor: at eight years the revision rate for pseudotumours in men was 0.5% (95% CI 0% to 1.1%), in women over 40 it was 6% (95% CI 2.3% to 10.1%) and in women under 40 it was 25% (95% CI 7.3% to 42.9%) (p< 0.001). Other factors associated with an increase in revision rate were, small components (p=0.003) and dysplasia (p=0.019), whereas implant type was not (p=0.156).

We recommend that resurfacings are undertaken with caution in women, especially those younger than 40 years of age, but they remain a good option in men. Further work is required to understand the patho-aetiology of pseudotumours so that this severe complication can be avoided.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 172 - 172
1 May 2011
Gill H Grammatopoulos G Pandit H Glyn-Jones S Whitwell D Mclardy-Smith P Taylor A Gundle R Murray D
Full Access

Introduction: Metal-on-metal hip resurfacing arthroplasty (MoMHRA) has gained popularity as an alternative to THR for younger patients with osteoarthritis. A growing concern has been the association of MoMHRA with the development of inflammatory pseudotumours (IP), especially in women. These have been linked to metal-on-metal wear, which can be related to metal ion concentrations. Elevated metal wear debris levels may result from impingement, rim contact and edge loading. Head-neck ratio (HNR) is a predetermining factor for range of movement and impingement. Neck thinning is a recognised phenomenon post-MoMHRA and we have found an association of IP with increased neck thinning based on a case control study. Our aims were to identify HNR changes a hip undergoes when resurfaced and at follow up; and whether greater neck thinning at follow-up could be associated with the presence of elevated metal ions.

Methods: A cohort of 91 patients (57M:34F) with unilateral MoMHRAs were included in this study. Blood tests were obtained at a mean follow up of 3.9 years (range 1.7–7 years) and serum (Co:Cr) ion levels were measured (ICPMS). High metal ion concentrations were defined as Co> 4.1ppb and Cr> 5.2ppb. For all patients, head-neck ratio (HNR) was measured on plain anterio-posterior pelvic radiographs pre-operatively, immediately post-operatively and at follow-up.

Results: Female patients had significantly bigger HNR pre-op (mean=1.35, range:1.22–1.64) compared to males(mean=1.22, range:1.05–1.38) (p< 0.01). Immediately post-op, female HNRs (mean: 1.26, range: 1.14–1.34) were not different to male patients(mean=1.24, range=1.11–1.38) (p=0.11). At follow-up HNR was once again significantly bigger (p< 0.01) in females (mean=1.35, range: 1.21–1.49), compare to males (mean=1.27, range:1.11–1.38). HNR alterations with operation (p=0.00) and at follow-up (p< 0.01) were significantly bigger in female patients. Furthermore, there was a significant correlation between high ion levels and HNR change at follow-up for both Co (p=0.02) and Cr (p< 0.01).

Conclusion: This study identified gender-specific changes in HNR that resurfaced hips undergo, not previously documented. Female hips have greater HNR pre-operatively, compared to male hips, and appear to be biomechanically disadvantaged when resurfaced. A decrease in HNR with resurfacing could result in impingement and lead to processes, known to be more prevalent in females, such as neck thinning, increased wear and IP development. In addition, we highlight a correlation between high ion levels and greater neck thinning at follow-up. Increased neck thinning in symptomatic MoMHRA hips could be secondary to increased wear and should be investigated further radiologically for the presence of IP.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 174 - 174
1 May 2011
Grammatopoulos G Kwon Y Langton D Pandit H Gundle R Whitwell D Mclardy-Smith P Murray D Gill H
Full Access

Introduction: Metal-on-metal hip resurfacing arthroplasty (MoMHRA) has gained popularity as an alternative to THR for younger patients with osteoarthritis. A growing concern has been the association of MoMHRA with the development of inflammatory pseudotumours (IP), especially in women. These have been linked to metal-on-metal wear, which can be related to metal ion concentrations. Although cup orientation has been shown to influence wear, the optimum cup position has not been clearly defined. We have identified an optimal cup orientation to minimise IP risk, based on a case controlled study, for inclination/anteversion within ±10° of 40°/20°. Our aim was to see if this optimal position results in lower metal ions, and to identify the boundary of an optimal placement zone for low wear.

Methods: A cohort of 104 patients (60M: 44F) with unilateral MoMHRA was included in this study. Blood tests were obtained at a mean follow up of 3.9 years (range 1.7–7 years) and serum Co and Cr ion levels were measured (ICPMS). High metal ion concentrations were defined as Co> 4.1ppb and Cr> 5.2ppb. Radiographic cup inclination and anteversion were measured using EBRA. The differences in ion levels between different cup orientation zones were investigated. Three orientation zones were defined centered on the target orientation of 40°/20°: Z1 within ±5°, Z2 outside ±5°/within ±10° and Z3: within ±10°.

Results: There was a wide range of cup placements; mean inclination/anteversion were 46.3°(21.5°–64.6°)/15°(2.7°–35.6°). Cr levels, but not Co, were higher in female patients (p=0.002) and those with small femoral components (< 50mm, p =0.03).

For the whole cohort, there was no significant difference in ion levels (Cr: p=0.092. Co=0.075) between cups positioned within Z3 (n=58) versus those outside (n=46 mean). Male patients with cups within Z3 (n=27) had lower ion levels in comparison to those outside Z3, which were significantly lower for Co (p=0.049) but not Cr (p=0.084). Female patients had similar levels within and out of Z3 for both ions (Cr: p=0.83, Co: p=0.84). However, patients with cups within Z1 (n=13) had significantly lower Co (p=0.005) and Cr (p=0.001) than those outside Z1 (n=95). Interestingly, Co levels were significantly lower in Z1 (n=13) in comparison to Z2 (n=33) (p=0.048) but Cr levels were not different (p=0.06).

Discussion: MoMHRA cups placed with ±5° of the ideal position of 40°/20°gave rise to significantly lower metal ions indicating lower wear within this narrow zone, in both sexes. This safe zone, could be extended to ±10° for male patients only. Gender specific factors, such as pelvic anatomy and joint flexibility, could be responsible for the narrower ‘safe’ zone seen in females. The narrower safe zone coupled with smaller components implanted are factors contributing to higher ion levels and hence the increased incidence of IP seen in females.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 223 - 223
1 May 2011
Grammatopoulos G Langton D Kwon Y Pandit H Gundle R Mclardy-Smith P Whitwell D Murray D Gill H
Full Access

Introduction: The development of Inflammatory Pseudotumour (IP) is a recognised complication following Metal on Metal Hip Resurfacing Arthroplasty (MoMHRA), thought to occur secondary to wear and elevated ion levels. Studies have shown that acetabular component orientation influences the wear of metal-on-metal hip replacement bearings. The aims of this study were to investigate the significance of cup orientation in the development of IP, and to identify a ‘safe-zone’ for cup placement with lower-risk for IP development.

Methods: Twenty six patients (n=27 hips) with IP confirmed radiologically, intra-operatively and histologically were matched for sex, age, pre-operative diagnosis, component size and follow-up with a cohort of asymptomatic MoMHRA patients (Control n=58). Radiographic acetabular anteversion and inclination were measured using EBRA. We calculated the distance in degree space of each acetabular component from the optimum position of 40° inclination and 20° anteversion, recommended by the designers, and thus compared acetabular component position between the two groups. Three different zones were tested as possibly optimum for acetabular placement. These were Lewinneck’s Zone (LZ) (inclination/anteversion; 30–50°/5–25°), and two zones defined by ±5° (Zone 1) or ± 10° (Zone 2) about the suggested target of 40°/20°. An optimal placement zone was determined based on a significant difference in IP incidence between components in the zone versus those outside.

Results: There was a wide range in cup orientations; mean inclination and anteversion were similar in the two groups: IP 47.5° (10.1°–80.6°)/14.1° (4.1°–33.6°) Vs Control 46.1° (28.8°–59.8°)/15.6° (4.3°–32.9°). Acetabular components in the IP group were significantly further away from the optimum position of 40°/20° in comparison to the controls (p=0.023). There was no difference in IP incidence between cups positioned within (IP:13/27, Control:35/58) or out of LZ (p=0.09) and within (IP: 2/27, Control: 10/58) or out of Zone 1 (p=0.156). Cups placed in Zone 2 (IP:6/27, Control:27/58) had significantly lower IP incidence versus those outside this zone (p=0.01). The odd’s ratio of developing IP when the cup is positioned out-of Zone 2 was 3.7.

Discussion: This study highlights the importance of ace-tabular component orientation in IP development. On the whole, patients with pseudotumour had acetabular components that were further away from the optimum position in comparison to the controls. However, a small number of IP patients had well-placed components implying that additional factors, possibly patient and/or gender specific, are involved in the development of pseudotumour. Furthermore, we defined an optimum, ‘safe-zone’ of ±10° around the cup position of 40°/20°. Patients with acetabular components outside this safe zone have an increased risk of IP development.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 26 - 26
1 Jan 2011
Gulati A Glyn-Jones S Simpson D Palan J Beard D Gill H McLardy-Smith P Gundle R Murray D
Full Access

Roentgen Stereophotogrammetric Analysis (RSA) can predict long-term outcome of prostheses by measuring migration over time. The Exeter femoral stem is a double-tapered highly polished implant and has been shown to subside within the cement mantle in 2 year RSA studies. It has a proven track record in terms of long-term survivorship and low revision rates. Several studies have demonstrated excellent clinical outcomes following its implantation but this is the first study to assess stem migration at 10 years, using RSA.

This is a single-centre study involving 20 patients (mean age: 63 years, SD=7) undergoing primary total hip replacement for degenerative osteoarthritis using the lateral (Hardinge) approach. RSA radiographs were taken with the patient bearing full weight post-operatively, at 3, 6, 12 months and at 2, 5 and 10 years follow-up. The three-dimensional migration of the Exeter femoral stem was determined.

The mean Oxford Hip Score at 10 years was 43.4 (SD=4.6) and there were no revisions. The stems subsided and rotated internally during a 10-year period. The mean migrations of the head and tip of the femoral stem in all three anatomic directions (antero-posterior, medio-lateral & supero-distal) were 0.69 mm posterior, 0.04 mm lateral and 1.67 mm distal for the head and 0.20 mm anterior, 0.02 mm lateral and 1.23 mm distal for the tip. The total migration at 10 years was 1.81 mm for the head and 1.25 mm for the tip.

The Exeter femoral stem exhibits migration which is a complex combination of translation and rotation in three dimensions. Comparing our 10 year with our previous 2 year migration results, the Exeter stems show continued, but slow distal migration and internal rotation. The subsidence continues to compress the cement and bone-cement interface which maintains secure fixation in the long term.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 66 - 67
1 Jan 2011
Kwon Y Thomas P Summer B McLardy-Smith P Ostlere S Gundle R Whitwell D Gibbons C Athanasou N Gill H Murray D
Full Access

Introduction: Symptomatic abnormal soft-tissue masses relating to the hip joint, such as those described as pseudotumours, are being increasingly reported following metal-on-metal hip resurfacing arthroplasty (MoMHRA). These were found to be locally destructive, requiring revision surgery in a high proportion (75%) of patients. Lymphocyte infiltrations seen in pseudotumours were similar to aseptic lymphocyte vascular associated lesion (ALVAL), which is thought to represent a T-lymphocyte-mediated delayed type hypersensitivity. Therefore, a delayed hypersensitivity reaction to nickel (Ni), chromium (Cr) or cobalt (Co) has been suggested to play a role in pseudotumour aetiology. In patients with bilateral MoMHRA who presented with symptoms on one side, subsequent scans have demonstrated pseudotumours both on the symptomatic and asymptomatic side. Thus, there are concerns that there may be an appreciable number of asymptomatic pseudotumours that surgeons are unaware of and these may eventually become symptomatic.

Aim: The aims of this study were:

to determine the prevalence of asymptomatic pseudotumours after MoMHRA; and

to measure Co and Cr ion levels as well as lymphocyte proliferation responses to Ni, Co and Cr (the principal elements in the CoCr alloy used in MoMHRA) in MoMHRA patients with and without asymptomatic pseudotumours.

Methods: A total of 201 MoMHRA implanted hips in 158 patients (97 male, 61 female) with a mean age of 56 years (range 33–73 years) were evaluated. The mean follow-up was 61 months (range 13–88 months). Resurfacing devices implanted included 128 Birmingham Hip Resurfacing, 66 Conserve Plus and seven ReCap. The control groups included additional 20 patients, 10 male and 10 female (a mean age 68 years, range 57–80 years) with metal-on-polyethylene total hip arthroplasty and a further 22 age-matched patients (a mean age 55 years) without any metal implants. Ultrasound was used as the initial imaging modality and MRI was used to assess the extent of the identified masses. Patients with a soft-tissue mass had ultrasound-guided aspiration or core biopsy performed. Venous blood samples were collected in all patients for serum cobalt and chromium ion levels analysis using Inductively-Coupled Plasma Mass Spectrometer and lymphocyte transformation tests (LTT). The Oxford Hip Score (OHS) was used to measure the functional outcomes of patients. Acetabular component abduction angle was measured from standardised anteroposterior pelvis radiographs.

Results: Prevalence – Pseudotumours were found in 7 patients (6 female and 1 male). The overall prevalence of asymptomatic pseudotumours was 4%, with a relatively very high (30%) prevalence in females with bilateral implants. Histological examinations showed extensive necrosis of connective tissue, in which there were scattered aggregates of metal particles and a diffuse lymphocyte infiltrate.

Metal Ion Levels – The presence of pseudotumour was associated with significantly higher median serum cobalt levels (9.2mg/L vs. 1.9mg/L, p< 0.001), chromium levels (12.0mg/L vs. 2.1mg/L, p< 0.001), hip aspirate cobalt levels (1182 mg/L vs. 86.2mg/L, p=0.003), and aspirate chromium levels (883mg/L vs. 114.8mg/ L, p=0.006), as well as with inferior functional scores (OHS 41 vs. 47 p< 0.001). There was no significant difference in acetabular cup inclination angle (p=0.51). Lymphocyte Reactivity: A higher incidence and level of enhanced lymphocyte reactivity to Ni (p=0.001), but not to Co or Cr (the principal elements in the CoCr alloy used in metal-on-metal hip resurfacing implants), was found in patients with MoMHRA compared to the patients without MoM implants. However, lymphocyte reactivity to Co, Cr and Ni did not significantly differ in patients with pseudotumours compared to those patients without pseudotumours.

Conclusion: The prevalence of asymptomatic pseudotumours in females was high, especially in females with bilateral MoMHRA implants (30%). The patients with ‘asymptomatic’ pseudotumours were in fact mildly symptomatic. Lymphocyte reactivity to Co, Cr and Ni did not differ in patients with pseudotumour compared to those patients without pseudotumours, suggesting that systemic hypersensitivity type IV reactions, mediated by lymphocyte reactivity to these metals, is not the dominant mechanism in pathogenesis of the soft tissue pseudotumours. Furthermore, pseudotumours were not detected in those patients who had normal levels of cobalt and chromium ions. This suggests that pseudotumours do not occur if MoM articulations are well functioning. Therefore, pseudotumours are likely to be a biological consequence of the large amount of metal debris generated in vivo due to excessive wear.