Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Bone & Joint Open
Vol. 4, Issue 11 | Pages 889 - 898
23 Nov 2023
Clement ND Fraser E Gilmour A Doonan J MacLean A Jones BG Blyth MJG

Aims

To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA).

Methods

This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_3 | Pages 9 - 9
1 Feb 2014
Halai M Gupta S Gilmour A Bharadwaj R Khan A Holt G
Full Access

Leg length discrepancy (LLD) can adversely affect functional outcome and patient satisfaction after total hip arthroplasty. We describe a novel intraoperative technique for femoral component insertion.

We aimed to determine if this technique resulted in the desired femoral placement, as templated, and if this was associated with a reduced LLD.

A series of fifty consecutive primary total hip replacements were studied. Preoperative digital templating was performed on standardised PA radiographs of the hips by the senior surgeon. The preoperative LLD was calculated and the distance from the superior tip of the greater trochanter to the predicted shoulder of the stem was calculated (GT-S). Intraoperatively, this length was marked on the rasp handle and the stem inserted to the predetermined level by the surgeon. This level corresponded to the tip of the greater trochanter and formed a continuous line to the mark on the rasp handle. Three independent blinded observers measured the GT-S on the postoperative radiographs. We assessed the relationship between the senior author's GT-S (preoperative) and the observers' GT-S (postoperative) using a Person correlation. The observers also measured the preoperative and postoperative LLD, and the inter-observer variability was calculated as the intra-class correlation coefficient.

There was a strong correlation of preoperative and postoperative GT-S (R=0.87), suggesting that the stem was inserted as planned. The mean preoperative and postoperative LLD were −4.3 mm (−21.4–4) and −0.9 mm (−9.8–8.6), respectively (p<0.001).

This technique consistently minimised LLD in this series. This technique is quick, non-invasive and does not require supplementary equipment.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 39 - 39
1 Aug 2013
Baird E Macdonald D Gilmour A Kumar C
Full Access

We aimed to review the outcome of Agility total ankle replacements carried out in our institution between 2002 and 2006.

Follow-up consisted of clinical and radiological review pre-operatively, then at 6 weeks, 6 and 12 months, and annually until 10 years post op. Clinical review included the American Orthopaedic Foot and Ankle Score, satisfaction and pain scores. Case notes were reviewed to determine intra and post-operative complications.

30 arthroplasties were performed in 30 consecutive patients. Pre-operative diagnosis was rheumatoid arthritis(16), primary osteoarthritis(12) and post-traumatic osteoarthritis(2). After a mean follow up of 6.2 years (1.4–10.1), 4 patients had died, and 22 out of the remaining 24 were available for follow-up. Intra operative complications included lateral malleoli fracture(3) and superficial peroneal nerve injury(2). Post operative complications included 1 early death, but this was not related to the surgical procedure. Two patients developed deep infections of the prosthesis. One underwent removal of the implant; the other is on long term oral antibiotic therapy. One patient had delayed union of the syndesmosis and six patients had non-union. On clinical assessment, patients' AOFAS scores improved from mean 40.4 pre-op to 83.5 post-op (p<0.001). Radiological assessment of the tibial component revealed 25 (93%) patients had lucency in at least one zone in the AP radiograph.

We found a relatively high level of re-surgery and complications following Agility total ankle replacement. A 7% revision rate is much higher than would be tolerated in knee or hip arthroplasty, but compares favourably to other studies of TAR. Despite radiological features which suggest loosening, the high rate of re-surgery and complications; patients are generally satisfied with the procedure, reporting lower levels of pain and improved function. Overall we feel that the Agility ankle is an acceptable alternative to ankle arthrodesis, however patients need to be warned of the risk of re-surgery.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_10 | Pages 1 - 1
1 Feb 2013
Baird E Macdonald D Gilmour A Kumar C
Full Access

We reviewed the outcome of Agility total ankle replacements carried out in our institution between 2002 and 2006.

Follow-up consisted of clinical and radiological review pre-operatively, at 6 weeks, 6 and 12 months, and annually until 10 years post-op. Clinical review included the American Orthopaedic Foot and Ankle Score, satisfaction and pain scores.

30 arthroplasties were performed in 30 consecutive patients. Pre-operative diagnosis was rheumatoid arthritis (16), primary osteoarthritis (12) and post-traumatic osteoarthritis (2). After a mean follow up of 6.2 years (1.4–10.1), 4 patients had died, and 20 out of the remaining 24 were available for follow-up. Complications included lateral malleoli fracture (3), superficial peroneal nerve injury (2), one early death, unrelated to the surgical procedure, delayed syndesmotic union (1), non-union (6) and deep infection (2), of which one underwent removal of the implant; the other receives long-term oral antibiotics. AOFAS scores improved from mean 40.4 pre-op to 83.5 post-op (p<0.001). Radiological assessment revealed 25 (93%) patients had lucency in at least one zone in the AP radiograph.

We found a relatively high level of re-surgery and complications following Agility total ankle replacement. A 7% revision rate is much higher than would be tolerated in knee or hip arthroplasty, but compares favourably to other studies of TAR. Despite radiological loosening, and the high rate of re-surgery and complications; patients are generally satisfied with the procedure, reporting lower levels of pain and improved function. Overall, we feel that the Agility ankle is an acceptable alternative to arthrodesis, however patients should be warned of the risk of re-surgery


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 58 - 58
1 Jan 2013
Baird E Macdonald D Gilmour A Kumar C
Full Access

We aimed to review the outcome of Agility total ankle replacements carried out in our institution between 2002 and 2006.

Follow-up consisted of clinical and radiological review pre-operatively, then at 6 weeks, 6 and 12 months, and annually until 10 years post op. Clinical review included the American Orthopaedic Foot and Ankle Score, satisfaction and pain scores. Case notes were reviewed to determine intra and post-operative complications.

30 arthroplasties were performed in 30 consecutive patients. Pre-operative diagnosis was rheumatoid arthritis(16), primary osteoarthritis(12) and post-traumatic osteoarthritis(2). After a mean follow up of 6.2 years (1.4–10.1), 4 patients had died, and 22 out of the remaining 24 were available for follow-up. Intra operative complications included lateral malleoli fracture(3) and superficial peroneal nerve injury(2). Post operative complications included 1 early death, but this was not related to the surgical procedure. Two patients developed deep infections of the prosthesis. One underwent removal of the implant; the other is on long term oral antibiotic therapy. One patient had delayed union of the syndesmosis and six patients had non-union. On clinical assessment, patients' AOFAS scores improved from mean 40.4 pre-op to 83.5 post-op (p< 0.001). Radiological assessment of the tibial component revealed 25 (93%) patients had lucency in at least one zone in the AP radiograph.

We found a relatively high level of re-surgery and complications following Agility total ankle replacement. A 7% revision rate is much higher than would be tolerated in knee or hip arthroplasty, but compares favourably to other studies of TAR. Despite radiological features which suggest loosening, the high rate of re-surgery and complications; patients are generally satisfied with the procedure, reporting lower levels of pain and improved function. Overall we feel that the Agility ankle is an acceptable alternative to ankle arthrodesis, however patients need to be warned of the risk of re-surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 65 - 65
1 Aug 2012
Gilmour A Richards J Redfern D
Full Access

Several authors have used 3D motion analysis to measure upper limb kinematics, but none have focused solely on wrist movements, in six degrees of freedom, during activities of daily living (ADL). This study aimed to determine the role of the different planar wrist movements during three standardised tasks, which may be affected by surgical procedures.

Nine volunteers (age range 22-45) were recruited and each participant performed three simulated ADLs: using a door lever, a door knob and opening/closing a jam jar. The ADLs were simulated using a work-sim kit on an isokinetic dynamometer. Motion analysis was performed by a 10-camera Oqus system (Qualisys Medical AB, Gothenburg, Sweden). All raw kinematic data were exported to Visual3D (C-Motion Inc.), where the biomechanical model was defined and joint kinematics calculated.

Table 1 shows a similar range of radial-ulnar deviation and flexion-extension as previous studies. However a substantial amount of wrist rotation also occurred in all tasks. This was significantly greater when using the door lever compared with the door knob and jam jar tasks.

Previous studies have stated that a negligible degree of rotation occurs at the wrist. This study found a maximum mean of 31.7 degrees of wrist rotation. This indicates that considerable rotational movement occurs at the wrist during certain functional tasks. Surgical approaches and clinical pathology may disrupt structures responsible for rotational stability. Further investigation of this rotational component of carpal movement during additional ADLs is proposed in both normal and clinical subjects, to explore the potential relationship between carpal surgery and rotational laxity.