Cite this article:
Acetabular fractures present a challenge. Anatomical reduction can be achieved by open reduction and internal fixation (ORIF). However, in elderly patients with complex fracture patterns and osteoporotic bone stock, “fix and replace” has become an option in the management of these injuries. This involves ORIF of the acetabulum to enable insertion of a press fit cup and subsequent cemented femoral stem at the index surgery. A Retrospective analysis of all operatively managed acetabular fractures by a regional Pelvic and Acetabular Trauma service (01/01/2018-30/05/2023) STATA used for analysis. 34 patients undergoing “fix and replace” surgery. Of the 133 patients managed with ORIF, 21 subsequently required Total Hip Arthroplasty (THA). Mean follow up was 2.7 years versus 5.1. There was no statistical significance between the two groups with regards to BMI or sex. Mean age in the “fix and replace” group was 68 compared to 48 in the ORIF and subsequent THA group. This reached statistical significance between the two groups (p=0.001).ASA and Charlson Comorbidity Index (3 and 3 in “fix and replace” and 2 and 1.2 in ORIF to THA group) and Charlson Comorbidity Index both were statistically significantly different (p=0.006 and p=0.027, respectively). High energy mechanism of injury accounted for 56% of the “fix and replace” group compared to 48% in the ORIF to THA. 74% of “fix and replace” were associated fractures compared to 53% of ORIF to THA. Wait to surgery was 3 days for “fix and replace” while 186 days was the mean wait time from listing to THA for the ORIF to THA group. Complication rate was 41% versus 43% in the two groups. 14% in the ORIF to THA group developed PJI versus 6% in “fix and replace”. Fix and replace allows early mobilisation in frailer, elderly patients. Our results show fewer returns to theatre and less PJI in patients having arthroplasty as part of “fix and replace” than subsequent to Open reduction internal fixation.
Treatment of Weber B ankle fractures that are stable on weightbearing radiographs but unstable on concomitant stress tests (classified SER4a) is controversial. Recent studies indicate that these fractures should be treated nonoperatively, but no studies have compared alternative nonoperative options. This study aims to evaluate patient-reported outcomes and the safety of fracture treatment using functional orthosis versus cast immobilization. A total of 110 patients with Weber B/SER4a ankle fractures will be randomized (1:1 ratio) to receive six weeks of functional orthosis treatment or cast immobilization with a two-year follow-up. The primary outcome is patient-reported ankle function and symptoms measured by the Manchester-Oxford Foot and Ankle Questionnaire (MOxFQ); secondary outcomes include Olerud-Molander Ankle Score, radiological evaluation of ankle congruence in weightbearing and gravity stress tests, and rates of treatment-related adverse events. The Regional Committee for Medical and Health Research (approval number 277693) has granted ethical approval, and the study is funded by South-Eastern Norway Regional Health Authority (grant number 2023014).Aims
Methods
To preserve knee function and reduce degenerative, meniscal tears should be repaired where possible. Meniscal wrapping with collagen matrices has shown promising clinical outcome (AAOS meniscal algorithm), however there is limited basic science to support this. to model the contact pressures on the human tibial plateau beneath a (1) a repaired radial meniscal tear and (2) a wrapped and repaired radial meniscal tear.Abstract
INTRODUCTION
AIM
Patient selection is key to the success of medial unicondylar knee arthroplasty (UKA). Progression of arthritis is the most common indication for revision. Various methods of assessing the lateral compartment have been used including stress radiography, radioisotope bone scanning, MRI, and visualisation at the time of surgery. Arthroscopy is another means of assessing the integrity of the lateral compartment. We used per-operative arthroscopy as a means to confirm suitability for UKA in a consecutive series of 279 Oxford medial UKA. This study reports the long-term results of a previously published cohort of knees. Our series of UKA with per-operative arthroscopy (Group 1) was compared to all Oxford UKA (Group 2) and all UKA in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) (Group 3).Abstract
Introduction
Methods
Musculoskeletal disorders have been recognised as common occupational risks for all orthopaedic surgeons. The nature of tasks performed by hip surgeons often requires both forceful and repetitive manoeuvres, potentially putting them at higher risk of musculoskeletal injuries compared to other orthopaedic sub-specialities. This study aimed to investigate the prevalence of musculoskeletal conditions among hip surgeons and evaluate the association between their workplace and lifestyle factors and musculoskeletal health. An online questionnaire consisting of 22 questions was distributed to UK-based consultant hip surgeons via email and social media platforms. This survey was completed by 105 hip surgeons. The mean age of the respondents was 49 years (range 35–69), with an average of 12 years (range 1–33) in service. 94% were full-time and 6% worked part-time. 49% worked at a district general hospital, 49% at a tertiary centre and 4% at a private institution. 80% were on the on-call rota and 69% had additional trauma commitments. 91% reported having one or more, 50% with three or more and 13% with five or more musculoskeletal conditions. 64% attributed their musculoskeletal condition to their profession. The most common musculoskeletal conditions were base of thumb arthritis (22%), subacromial impingement (20%), degenerative lumbar spine (18%) and medial or lateral epicondylitis (18%). 60% stated that they experienced lower back pain. Statistical analysis showed that being on the on-call rota was significantly (P<0.001) associated with a higher musculoskeletal burden. Regular resistance and/or endurance training and BMI<30 were statistically significant protective factors (P<0.001). Over the last few decades, most of the hip-related literature has focused on improving outcomes in patients, yet very little is known about the impact of hip surgery on the musculoskeletal health of hip surgeons. This study highlights a high prevalence of musculoskeletal conditions among UK-based hip surgeons. Hip surgeons have a pivotal role to play in the ongoing recovery of elective orthopaedics services. There is a pressing need for the identification of preventative measures and improvement in the surgical environment of our hip surgeons.
Conventional proximal tibial osteotomy is a widely successful joint-preserving treatment for osteoarthritis; however, conventional procedures do not adequately control the posterior tibial slope (PTS). Alterations to PTS can affect knee instability, ligament tensioning, knee kinematics, muscle and joint contact forces as well as range of motion. This study primarily aimed to provide a comprehensive investigation of the variables influencing PTS during high tibial osteotomy using a 3D surgical simulation approach. Secondly, it aimed to provide a simple means of implementing the findings in future 3D pre-operative planning and /or clinically. The influence of two key variables: the gap opening angle and the hinge axis orientation on PTS was investigated using three independent approaches: (1) 3D computational simulation using CAD software to perform virtual osteotomy surgery and simulate the post-operative outcome. (2) Derivation of a closed-form mathematical solution using a generalised vector rotation approach (3) Clinical assessment of synthetically generated x-rays of osteoarthritis patients (n=28; REC reference: 17/HRA/0033, RD&E NHS, UK) for comparison against the theoretical/computational approaches. The results from the computational and analytical assessments agreed precisely. For three different opening angles (6°, 9° and 12°) and 7 different hinge axis orientations (from −30° to 30°), the results obtained were identical. A simple analytical solution for the change in PTS, ΔPs, based on the hinge axis angle, α, and the osteotomy opening angle, θ, was derived: ΔPs=sin-1(sin α sin θ) The clinical assessment demonstrated that the absolute values of PTS, and changes resulting from various osteotomies, matched the results from the two relative prediction methods. This study has demonstrated that PTS is impacted by the hinge axis angle and the extent of the osteotomy opening angle and provided computational evidence and analytical formula for general use.
High tibial osteotomy (HTO) is an effective surgical treatment for isolated medial compartment knee osteoarthritis; however, widespread adoption is limited due to difficulty in achieving the planned correction, and patient dissatisfaction due to soft tissue irritation. A new HTO system – Tailored Osteotomy Knee Alignment (TOKA®, 3D Metal Printing Ltd, Bath, UK) could potentially address these barriers having a custom titanium plate and titanium surgical guides featuring a unique mechanism for precise osteotomy opening as well as saw cutting and drilling guides. The aim of this study was to assess the accuracy of this novel HTO system using cadaveric specimens; a preclinical testing stage ahead of first-in-human surgery according to the ‘IDEAL-D’ framework for device innovation. Local ethics committee approval was obtained. The novel opening wedge HTO procedure was performed on eight cadaver leg specimens. Whole lower limb CT scans pre- and post-operatively provided geometrical assessment quantifying the discrepancy between pre-planned and post-operative measurements for key variables: the gap opening angle and the patient specific surgical instrumentation positioning and rotation - assessed using the implanted plate. The average discrepancy between the pre-operative plan and the post-operative osteotomy correction angle was: 0.0 ± 0.2°. The R2 value for the regression correlation was 0.95. The average error in implant positioning was −0.4 ± 4.3 mm, −2.6 ± 3.4 mm and 3.1 ± 1.7° vertically, horizontally, and rotationally respectively. This novel HTO surgery has greater accuracy and smaller variability in correction angle achieved compared to that reported for conventional or other patient specific methods with published data available. This system could potentially improve the accuracy and reliability of osteotomy correction angles achieved surgically.
This study investigated the effects of transcatheter arterial embolization (TAE) on pain, function, and quality of life in people with early-stage symptomatic knee osteoarthritis (OA) compared to a sham procedure. A total of 59 participants with symptomatic Kellgren-Lawrence grade 2 knee OA were randomly allocated to TAE or a sham procedure. The intervention group underwent TAE of one or more genicular arteries. The control group received a blinded sham procedure. The primary outcome was knee pain at 12 months according to the Knee injury and Osteoarthritis Outcome Score (KOOS) pain scale. Secondary outcomes included self-reported function and quality of life (KOOS, EuroQol five-dimension five-level questionnaire (EQ-5D-5L)), self-reported Global Change, six-minute walk test, 30-second chair stand test, and adverse events. Subgroup analyses compared participants who received complete embolization of all genicular arteries (as distinct from embolization of some arteries) (n = 17) with the control group (n = 29) for KOOS and Global Change scores at 12 months. Continuous variables were analyzed with quantile regression, adjusting for baseline scores. Dichotomized variables were analyzed with chi-squared tests.Aims
Methods
Australian Football (AF) is a popular sport in Australia, with females now representing one-third of participants. Despite this, the injury profiles of females versus males in largely unknown. The current study investigated fractures, dislocations and tendon ruptures in females versus males presenting to emergency departments (ED) with an AF injury. All patients, regardless of age, presenting to one of 10 EDs in Victoria, Australia, with an AF injury were included. Data were prospectively collected over a 10-month period, coinciding with a complete AF season. Data were extracted from patient medical records regarding injury-type, body-part injured and treatments required. Female and male data were compared with chi-squared tests. Of the 1635 patients presenting with an AF injury, 595 (36.0%) had a fracture, dislocation or tendon rupture, of whom 85 (14.3%) were female and the average age was 20.5 years (SD 8.0). Fractures accounted for most injuries (n=478, 80.3% of patients had a fracture), followed by dislocations (n=118, 19.8%) and tendon ruptures (n=14, 2.4%). Upper limb fractures were more common than lower limb fractures (71.1% v 11.5% of fractures). Females were more likely to fracture their hands or fingers than males (45.7% v 34.3%). Males were more likely to fracture ribs (5.4% v 0%). Most fractures (91.2%) were managed in the ED, with the remainder being admitted for surgery (GAMP/ORIF). Males were more likely to be admitted for surgery than females (11.2% v 5.9%). Regarding dislocations (n=118), females were more likely to dislocate the patella (36.8% v 8.1% of dislocations). Only males sustained a tendon rupture (n=14): finger extensor or flexor (57.1%), achilles tendon (28.6%) and patella tendon (14.3%). Orthopaedic AF injuries are common presentations to EDs in Victoria, though few require specialist orthopaedic intervention. Injury profiles differed between genders suggesting that gender specific injury prevention and management might be required.
Osteoarthritis (OA) is a disease of the synovial joint with synovial inflammation, capsular contracture, articular cartilage degradation, subchondral sclerosis and osteophyte formation contributing to pain and disability. Transcriptomic datasets have identified genetic loci in hip and knee OA demonstrating joint specificity. A limited number of studies have directly investigated transcriptional changes in shoulder OA. Further, gene expression patterns of periarticular tissues in OA have not been thoroughly investigated. This prospective case control series details transcriptomic expression of shoulder OA by analysing periarticular tissues in patients undergoing shoulder replacement for OA as correlated with a validated patient reported outcome measure of shoulder function, an increasing (clinically worsening) QuickDASH score. We then compared transcriptomic expression profiles in capsular tissue biopsies from the OA group (N=6) as compared to patients undergoing shoulder stabilisation for recurrent instability (the control group, N=26). Results indicated that top ranked genes associated with increasing QuickDASH score across all tissues involved inflammation and response to stress, namely interleukins, chemokines, complement components, nuclear response factors and immediate early response genes. Some of these genes were upregulated, and some downregulated, suggestive of a state of flux between inflammatory and anti-inflammatory signalling pathways. We have also described gene expression pathways in shoulder OA not previously identified in hip and knee OA, as well as novel genes involved in shoulder OA.
In Australia nearly two-thirds of arthroplasty procedures are performed in the private setting, which is disproportionate to the dimensioning 43.5% of the population with private health cover. The rapid growth of shoulder arthroplasty surgery will be absorbed by both private and public sectors. This study aimed to assess the influence of healthcare setting on elective shoulder arthroplasty outcomes, defined by revision rate, and functional measures. Data was collected on all primary procedures performed from 2004 – 2019 within a regional area of Victoria, Australia. Patients were categorised into private or public settings. Trauma cases for acute proximal humerus fractures were excluded. The primary outcome of revision surgery was recorded as a cumulative percentage, and survival analysis conducted to calculate a hazard ratio (HR). Functional outcomes were measured through range-of-motion (ROM) and multiple validated patient-reported-outcome-measures (PROMs). 458 patients were identified in the study: 290 private and 168 public. There was no difference in the revision rate (3.8% private, 4.8% public), with an adjusted HR of 1.25 (p=0.66) for public compared to private. Baseline and post-operative functional measures were significantly greater in the private setting for ROMs and PROMs analysis, in particular post-operative QuickDASH (15.9±14.7 to 32.7±23.5; p<0.001) and Oxford Shoulder Score (42.6±6.3 to 35.7±11.2; p<0.001). However, there was no significant difference for any of the functional measures in the amount of change from baseline to 12-months between settings. Although healthcare setting does not appear to influence revision rate for shoulder arthroplasty, clear differences were demonstrated for functional measures both pre and post operatively. This may be attributed to factors such as access to perioperative rehabilitation and should be an area to target future investigations.
The progressive painful and disabling predicament of patients with severe osteoarthritis awaiting a total hip or knee arthroplasty (THA/TKA) results in a decline in muscle mass, strength and function also known as Sarcopenia. We conducted a cross-sectional, prospective study of patients on the waiting-list for a THA/TKA in the South Australian public healthcare system and compared the findings to healthy participants and patients newly referred from their general practitioners. Participants with a history of joint replacements, pacemakers and cancers were excluded from this study. Outcomes of this study included (i) sarcopenia screening (SARC-F ≥4); (ii) sarcopenia, defined as low muscle strength (hand grip strength M<27kg; F<16kg), low muscle quality (skeletal muscle index M<27%, F<22.1%) and low physical performance (short physical performance battery ≤8). Additional outcomes include descriptions of the recruitment feasibility, randomisation and suitability of the assessment tools. 29 healthy controls were recruited; following screening, 83% (24/29) met the inclusion criteria and 75% (18/24) were assessed. 42 newly referred patients were recruited; following screening, 67% (30/45) met the inclusion criteria and 63% (19/30) were assessed. 68 waiting list patients were recruited; following recruitment, 24% (16/68) met the inclusion criteria and 75% (12/16) were assessed. Preliminary data shows increasing waiting time is associated with higher SARC-F scores, lower hand grip strength and lower muscle quality. As a pilot study, preliminary data demonstrate that: (1) study subjects’ willingness to participate will enable a larger study to be conducted to establish the prevalence of sarcopenia and the diagnostic cut-off points for this patient group. (2) SARC-F is a suitable tool to screen for sarcopenia. (3) There is a positive correlation between waiting time for a THA/TKA and sarcopenia.
We compared the rate of revision of two classes of primary anatomic shoulder arthroplasty, stemmed (aTSA) and stemless (sTSA) undertaken with cemented all polyethylene glenoid components. A large national arthroplasty registry identified two cohort groups for comparison, aTSA and sTSA between 1st January 2011 and 31st December 2020. A sub-analysis from 1 January 2017 captured additional patient demographics. The cumulative percentage revision (CPR) was determined using Kaplan-Meier estimates of survivorship and hazard ratios (HR) from Cox proportional hazard models adjusted for age and gender. Of the 7,533 aTSA procedures, the CPR at 8 years was 5.3% and for 2,567 sTSA procedures was 4.0%. There was no difference in the risk of revision between study groups (p=0.128). There was an increased risk of revision for aTSA and sTSA undertaken with humeral head sizes <44mm (p=0.006 and p=0.002 respectively). Low mean surgeon volume (MSV) (<10 cases per annum) was a revision risk for aTSA (p=0.033) but not sTSA (p=0.926). For primary diagnosis osteoarthritis since 2017, low MSV was associated with an increased revision risk for aTSA vs sTSA in the first year (p=0.048). Conversely, low MSV was associated with a decreased revision risk for sTSA in the first 6 months (p<0.001). Predominantly aTSA was revised for loosening (28.8%) and sTSA for instability/dislocation (40.6%). Revision risk of aTSA and sTSA was associated with humeral head size and mean surgeon volume but not patient characteristics. Inexperienced shoulder arthroplasty surgeons experience lower early revision rates with sTSA in the setting of osteoarthritis. Revision of aTSA and sTSA occurred for differing reasons.
Spinal local anaesthesia and opioids have long been used as peri-operative analgesia for patients undergoing arthroplasty procedures. However, intrathecal opioids are associated with numerous complications. ERAS® society guidelines for elective knee replacement (2019) strongly discourage the use of spinal opioids. This study aims to report the impact of low-dose spinal and local infiltrative analgesia on patients undergoing elective knee replacement. Retrospective cohort study of patients undergoing knee replacement under the ERAS protocol over 2 years, at a district general hospital under the care of a single surgeon.Abstract
Introduction
Methodology
High tibial osteotomy for knee realignment is effective at relieving symptoms of knee osteoarthritis but the operation is surgically challenging. A new personalised treatment with simpler surgery using pre-operatively planned measurements from computed tomography (CT) imaging and 3D-printed implants and instrumentation has been designed and is undergoing clinical trial. The aim of this study was to evaluate the early clinical results of a preliminary pilot study evaluating the safety of this new personalised treatment. The single-centre prospective clinical trial is ongoing (IRCCS Istituto Ortopedico Rizzoli; IRB-0013355; ClinicalTrials.gov NCT04574570), with recruitment completed and all patients having received the novel custom surgical treatment. To preserve the completeness of the trial reporting, only surgical aspects were evaluated in the present study. Specifically, the length of the implanted osteosynthesis screws was considered, being determined pre-operatively eliminating intraoperative measurements, and examined post-operatively (n=7) using CT image processing (ScanIP, Synopsys) and surface distance mapping. The surgical time, patient discharge date and ease of wound closure were recorded for all patients (n=25).Abstract
Objectives
Methods
Additive manufacturing has led to numerous innovations in orthopaedic surgery: surgical guides; surface coatings/textures; and custom implants. Most contemporary implants are made from titanium alloy (Ti-6Al-4V). Despite being widely available industrially and clinically, there is little published information on the performance of this 3D printed material for orthopaedic devices with respect to regulatory approval. The aim of this study was to document the mechanical, chemical and biological properties of selective laser sintering (SLS) manufactured specimens following medical device (TOKA®, 3D Metal Printing LTD, UK) submission and review by the UK Medicines and Healthcare Products Regulatory Agency (MHRA). All specimens were additively manufactured in Ti-6Al-4V ELI (Renishaw plc, UK). Mechanical tests were performed according to ISO6892-1, ISO9585 and ISO12107 for tensile (n=10), bending (n=3) and fatigue (n=16) respectively (University of Bath, UK). Appropriate chemical characterisation and biological tests were selected according to recommendations in ISO10993 and conducted by external laboratories (Wickham Labs, UK; Lucideon, UK; Edwards Analytical, UK) in adherence with Good Lab Practise guidelines. A toxicological review was conducted on the findings (Bibra, UK).Abstract
Objectives
Methods
Medial Knee Osteoarthritis (MKO) is associated with abnormal knee varism, this resulting in altered locomotion and abnormal loading at tibio-femoral condylar contacts. To prevent end-stage MKO, medial compartment decompression is selectively considered and, when required, executed via High Tibial Osteotomy (HTO). This is expected to restore normal knee alignment, load distribution and locomotion. In biomechanics, HTO efficacy may be investigated by a thorough analysis of the ground reaction forces (GRF), whose orientation with respect to patient-specific knee morphology should reflect knee misalignment. Although multi-instrumental assessments are feasible, a customized combination of medical imaging and gait analysis (GA), including GRF data, rarely is considered. The aim of this study was to report an original methodology merging Computed-Tomography (CT) with GA and GFR data in order to depict a realistic patient-specific representation of the knee loading status during motion before and after HTO. 25 MKO-affected patients were selected for HTO. All patients received pre-operative clinical scoring, and radiological/instrumental assessments; so far, these were also executed post-operatively at 6-month follow-up on 7 of these patients. State-of-the-art GA was performed during walking and more demanding motor tasks, like squatting, stair-climbing/descending, and chair-rising/sitting. An 8-camera motion capture system, combined with wireless electromyography, and force platforms for GRF tracking, was used together with an own established protocol. This marker-set was enlarged with 4 additional skin-based non-collinear markers, attached around the tibial-plateau rim. While still wearing these markers, all analyzed patients received full lower-limb X-ray in standing posture a CT scan of the knee in weight-bearing Subsequently, relevant DICOMs were segmented to reconstruct the morphological models of the proximal tibia and the additional reference markers, for a robust anatomical reference frame to be defined on the tibia. These marker trajectories during motion were then registered to the corresponding from CT-based 3D reconstruction. Relevant registration matrices then were used to report GRF data on the reconstructed tibial model. Intersection paths of GRF vectors with respect to the tibial-plateau plane were calculated, together with their centroids.Introduction and Objective
Materials and Methods
Global surgical literature suggests that female trainees have less operative autonomy than their male counterparts. This pilot study had the primary objective to identify difference in autonomy by gender, and to power a national study to carry out further quantitative and qualitative research on this. This was a retrospective, cross-sectional study utilising eLogbook data for all orthopaedic trainees (ST2-8) and consultants with CCT date 2016–2021 in a single Scottish deanery. The primary outcome measure was percentage of procedures undertaken as lead surgeon. 15 trainees and four recent consultants participated, of which 12 (63%) were male (mean grade 5.2), and 7 (37%) were female (mean grade 4.3). Trainees were lead surgeon on 64% of procedures (17595/27558), with autonomy rising with grade (37% ST1 to 85% ST8, OR 9.4). Operative autonomy was higher in male vs female trainees (66.5% and 61.4% respectively, p=<0.0001), with female trainees more likely to operate with a supervisor present (STU/S vs P/T, f 48%:13%, m 45%:20%). This pilot study found that there was a significant difference in operative autonomy between male and female trainees, however this may be explained by differences in mean grade of male vs female trainees. Five trainees took time OOT, 4/5 of whom were female. Extension to a national multi-centre study should repeat the quantitative method of this study with additional qualitative analysis including assessing effect of time OOT to explore the reason for any gender discrepancies seen across different deaneries in the UK.
Carbon fibre (CF) instrumentation is known to be radiolucent and has a tensile strength similar to metal. A specific use could be primary or oligometastatic cancer where regular surveillance imaging and Stereotactic Radiotherapy are required. CT images are inherently more prone to artefacts which affect Hounsfield unit (HU) measurements. Titanium (Ti) screws scatter more artefacts. Until now it has been difficult to quantify how advantageous the radiolucency of carbon fibre pedicle screws compared to titanium or metallic screws actually is. In this retrospective study, conducted on patients from 2018 to 2020 in SGH, we measured the HU to compare the artifact produced by CF versus Ti pedicle screws and rods implanted in age and sex matched group of patients with oligometastatic spinal disease.Background
Methodology