Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 39 - 39
1 May 2017
Gee C Poole W Wilson D Gibbs J Stott P
Full Access

Adverse reaction to metal debris (ARMD) is well recognised as a complication of large head metal on metal total hip replacement (THR) leading to pain, bone and tissue loss and the need for revision surgery. An emerging problem of trunnionosis in metal on polyethylene total hip replacements leading to ARMD has been reported in a few cases. Increased metal ion levels have been reported in THR's with a titanium stem and a cobalt chrome head such as the Accolade-Trident THR (Stryker).

We present 3 cases of ARMD with Accloade-Trident THR's with 36mm cobalt chrome head and a polyethylene liner. Metal ion levels were elevated in all three patients (cobalt 10.3 – 161nmol/l). Intraoperative tissue samples were negative for infection and inflammatory markers were normal. Abnormal fluid collections were seen in all three cases and bone loss was severe in one patient leading to a proximal femoral replacement. Histology demonstrated either a non-specific inflammatory reaction in a case which presented early or a granulomatous reaction in a more advanced case suggesting a local foreign body reaction. All patients had improved symptoms post-operatively. 1 patient who had staged bilateral Accolade-Trident THR's required revision of both THR's.

ARMD in metal on polyethylene THR's with a titanium stem represents a potential emerging problem. Further studies are required to assess whether these occurrences are rare or represent the tip of an iceberg.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_2 | Pages 3 - 3
1 Jan 2013
Wright B Gibbs J Elliott D
Full Access

Standard Ilizarov technique uses the tensioned olive wires to provide interfragmentary compression in the acute fracture setting and in non-union surgery. In osteopenic metaphyseal bone this can lead to the olive “cutting through” the thin attenuated cortex reducing compression and stability.

We describe a technique placing a percutaneous 3 hole Synthes Mini-fragment plate against the outer cortex of the bone fragment. An olive wire is then placed through each of the outer two holes and through the bone fragment. The construct is then tensioned. This stops the olive cutting into the bone and allows increased compression which is particularly important in non-union surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 75 - 75
1 Sep 2012
Khakha R Gibbs J Hull J Perry A Chissell H Hill P
Full Access

Introduction

It is now widely accepted that acute knee dislocations should be managed operatively. Most published studies are from outside the UK and from major trauma or specialist centres. The aim of the study is to report the functional outcomes of all patients presenting with an acute knee dislocation at our institution all of whom were surgically managed. The results were then compared to other published series. The hypothesis being that there would be no significant difference in the functional outcome scores between the groups.

Methods

All patients presenting with an acute knee dislocation over the last 15 years were included in the study. The patients were followed up using functional assessment scores: Knee outcome score (ADL), Knee outcome score (sports), Tegner Lysholm Scores and overall Patient Satisfaction. The patients were classified according to the Schecnk classification of knee dislocations.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 99 - 99
1 Jul 2012
Gibbs J Khakha R Hull J Perry A Chissell H Hill P
Full Access

Introduction

It is now widely accepted that acute knee dislocations should be managed operatively. Most published studies are from outside the UK and from major trauma or specialist centres. The aim of the study is to report the functional outcomes of all patients presenting with an acute knee dislocation at our institution all of whom were surgically managed. The results were then compared to other published series. The hypothesis being that there would be no significant difference in the functional outcome scores between the groups.

Methods

All patients presenting with an acute knee dislocation over the last 15 years were included in the study. The patients were followed up using functional assessment scores: Knee outcome score (ADL), Knee outcome score (sports), Tegner Lysholm Scores and overall Patient Satisfaction. The patients were classified according to the Schecnk classification of knee dislocations.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 173 - 174
1 Mar 2006
Ridgeway S Bhatnagar P Kharendesh P Gibbs J Newman K Khaleel A Elliott D
Full Access

Aim: To describe a radiographic biomechanical classification of tibial plateau fractures which dictates treatment. To compare the intra- and interobserver reliability and reproducibility of this, the Chertsey (C1-3) classification, and the Schatzker (SK1-6) classification.

Method: This classification system has been used at this institution for 8 years by the orthopaedic trauma consultants and consists of C1 – valgus fractures, C2 – Varus fractures and C3 axial fractures. Our treatment regime is based on this classification and results presented in a sperate study. These consultants were excluded from the study on reliability and reproducibility. 2 Orthopaedic consultants, 2 orthopaedic registrars and 2 radiologists were selected randomly to classify 30 sets of AP and Lateral radiographs, of randomly selected patients treated in this institution with tibial plateau fractures, consisting of 9 SK1-3/C1, 8 SK4/C2 and 13 SK5,6/C3 fractures, and again with the same radiographs in a random order 1 month later. Radiographs of fractures treated conservatively were excluded. Statistical analysis included Kappa concordance according to Landis and Koch, and the Mann-Whitney U test.

Results: The Schatzker system was only moderately reliable (K=0.66), and the Chertsey classification system significantly more reliable (K=0.82) (p=0.03) with regards to interobserver reliability. Excellent reproducibility (intra-observer reliability) was seen amongst all observers. The consultant orthopaedic surgeons were significantly more reliable than the radiologists, but not the orthopaedic registrars. No particular fracture type in any classification proved to be significantly more difficult to classify.

Conclusion: We present a classification used in our institution based on plain radiographs, which depicts investigations and treatment. The Chertsey classification is significantly more reliable between observers than the Schatzker classification and is reproducible.