We have developed plasmonic fibrin-based hydrogels that incorporate gold nanoparticles which transduce incident near-infrared (NIR) light into heat. Human adenovirus serotype type-5 vectors encoding a firefly luciferase (fLuc) coding sequence driven by a heat-inducible promoter were incorporated into the hydrogels. Transmission electronic microscopic analysis revealed that the adenoviral vectors were associated to the fibrin fibers. In vitro experiments in which human cells were cultured with plasmonic hydrogels showed that the adenoviral vectors can diffuse from the hydrogels, transduce the cells, and stimulate heat-induced transgene expression upon NIR irradiation. The hydrogels were implanted in 4.2 mm drill hole defects generated in the humerus of male rabbits. Three days after implantation, the defects were NIR-irradiated. Six h later, the animals were euthanized and samples from the bone defect zone were processed for immunohistochemical analyses using a specific fLuc antibody. The results showed strong expression of fLuc in tissues surrounding the implants of NIR-irradiated rabbits, while non- irradiated animals exhibited negligible expression. We next aimed to use the temperature increase to induce the production of transgenic bone morphogenetic protein 6 (BMP-6), using safe gene switches that can provide tighter control of in vivo transgene expression than heat-inducible promoters. These switches are only activated by heat in the presence of rapamycin and maintain a high level of targeted transgene expression for several days after heat activation. Adenoviral vectors encoding the safe switches that control the expression of BMP-6 were incorporated to the composites. The resulting NIR-responsive hydrogels were implanted in the bone defects generated in rabbits and used as a platform to transduce host cells, generate local hyperthermia and stimulate BMP-6 production.
To compare the incidence of Bone Cement Implantation Syndrome (BCIS), perioperative thromboembolic events and mortality in patients with a femoral neck fracture (FNF) treated with a hybrid total hip arthroplasty (THA) without intraoperative unfractioned heparin (UFH) (control) versus a group of patients who received intraoperative UFH before femoral cementation. We retrospectively reviewed 273 patients who underwent hybrid THA due to a FNF between 2015 and 2020. We compared a group of 139 patients without intraoperative administration of UFH (group A) with 134 patients who underwent THA with intraoperative administration of 10 UI/kg UFH (group B). UFH indication was dependent on surgeon´s preference. We assessed the advent of BCIS and 30-day thromboembolic events, as well as 90-day and 1-year mortality. BCIS was observed in 51 cases (18%), defined as Grade 1 (O2% < 94% or fall in systolic blood pressure of 20% to 40%) in 37 cases (13%) and Grade 2 (O2% < 88% or fall in systolic blood pressure of > 40%) in 14 cases (5%). Forty-seven BCIS (35%) were observed in the group that received UFH and 4 BCIS (3%) in the control group (p <0.001). Multivariate regression model showed that intraoperative UFH (OR=18, CI95% 6–52) and consumption of oral anticoagulants (OR=3.3, CI95% 1–10) had an increased risk of developing BCIS. Five patients developed a pulmonary embolism in the UFH group while 2 patients presented this complication in the non UFH group (p=0.231). Mortality was 1% for both groups at 90 days PO (p= 0.98), 2% at 1 year for group A and 3% for group B (p =0.38). BCIS in our series was 18%. We found a paradoxically 17-fold significant increase of BCIS with the use of UFH. Heparin did not prevent BCIS, thromboembolic events and mortality in this group of patients.
Bone-regenerative and biocompatible materials are indicated for the regeneration of bone lost in periodontology and maxillofacial surgery. Bio-Oss is a natural bone mineral for bone grafting of bovine origin and the most common used in this kind of interventions1. Sil-Oss is a new synthetic nanostructured monetite-based material that is reabsorbed at the same time that is replaced by new bone tissue 2. Bacterial infection is one of the complications related to this kind of material.
Bacterial adherence decreased significantly on Sil-Oss compared to Bio-Oss. Sil-Oss nanostructured monetite-based biomaterial could be considered as a promising biomaterial to be used for the regeneration of bone defects since the bacterial adherence on it is lower than on another currently used material.
To determine the limits of spinal displacement before the onset of neurophysiological changes during spinal surgery. Assessing if the type of force applied or the section of the adjacent nerve roots increases the tolerance to displacement. Experimental study in 21 domestic pigs. Three groups were established according to the displacing force applied to the cord: separation (group 1, n=7), root stump pull (group2, n=7) and torque (group3, n=7). Successive records of cord-to-cord motor evoked potential were obtained. The displacing force was removed immediately when neurophysiological changes observed. The experiment was repeated after sectioning the adjacent nerve roots.Objectives
Methods
To determine whether delayed diagnosis (lapse from initial symptoms to the beginning of treatment) has influence on the possibilities of crossing the physis by the tumour, and/or on the outcome in pediatric patients with high grade metaphyseal osteosarcoma. The clinical records, image methods and the histology reports of 157 metaphyseal paediatric osteosarcomas were reviewed. The mean follow-up time was 102 months. Location, histological subtype, time from initial symptoms to start of treatment, major diameter, % of necrosis, physis crossed by the tumour or not, and outcome (recurrence, metastases and status) were recorded in a SPSS v15.0 file.Aim
Patients and methods
Tissue culture was positive in 9 THA, 11 TKA 18 OS and 4 SI. Sonication culture was positive in 14 THA, 18TKA, 23 Os and 6 SI. Tissue culture: Sensibility: THA53%, TKA 55%, OS 75% and SI 66%. Specificity: THA 96%, TKA 100%, OS 96%, SI 100% Sonications: Sensibility: THA 82%, TKA 90%, OS 95% and SI 100%. Specificity: THA 96%, TKA 100%, OS 92%, SI 100% Statistical differences favoring sonication were found in sensitivity in knee arthroplasty and osteosynthesis implants. 6 patients received antibiotics for >
7 days before implant was removed. Sonication culture was positive in 4 of them whereas only one standard culture yielded positive.