Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 14 - 14
1 Mar 2021
Au K Gammon B Undurraga S Culliton K Louati H D'Sa H
Full Access

The clinical diagnosis of distal radioulnar joint (DRUJ) instability remains challenging. The current diagnostic gold standard is a dynamic computerized topography (CT) scan. This investigation compares the affected and normal wrists in multiple static positions of forearm rotation.. However, its accuracy has been questioned, as the wrist is unloaded and not placed under stress. This may fail to capture DRUJ instability that does not result in static malalignment between the ulnar head and sigmoid notch. The purpose of this biomechanical study was to evaluate the effectiveness of both dynamic and stress CT scans in detecting DRUJ instability.

A customized DRUJ arthrometer was designed that allows for both static positioning, as well as dorsal and volar loading at the DRUJ in various degrees of forearm rotation. Ten fresh frozen cadavers were prepared and mounted in the apparatus. CT scans were performed both in the unloaded condition (dynamic CT) and with each arm subjected to a standardized 50N volar and dorsal force (stress CT) in neutral and maximum pronation/ supination. The TFCC (triangular fibrocartilage complex)was then sectioned peripherally to simulate DRUJ instability and the methodology was repeated. CT scans were then evaluated for displacement using the radioulnar ratio method.

When calculating the radioulnar ratio for intact wrists using the dynamic CT technique, values were 0.50, 0.64, 0.34 for neutral, pronation and supination, respectively. When the TFCC was sectioned and protocol repeated, the values for the simulated unstable wrist for dynamic CT were 0.54, 0.62, 0.34 for neutral, pronation and supination, respectively. There was no statistically significant difference between the intact and sectioned states for any position of forearm rotation using dynamic CT. Usingstress CT, mean radioulnar ratios for the intact specimens were calculated to be 0.44, 0.36 and 0.31 for neutral, pronation and supination, respectively. After sectioning the TFCC, the radioulnar ratios increased to 0.61, 0.39 and 0.46 for neutral, pronation and supination. There was a statistically significant difference between intact and simulated-unstable wrists in supination (p = 0.002) and in neutral (p=0.003).

The radioulnar ratio values used to measure DRUJ translation for dynamic CT scans were unable to detect a statistically significant difference between stable and simulated unstable wrists. This was true for all positions of forearm rotation. However, when a standard load was placed across the DRUJ, statically significant changes in the radioulnar ratio were seen in neutral and supination between stable and simulated unstable wrists. This discrepancy challenges the current gold standard of dynamic CT in its ability to accurately diagnosis DRUJ instability. It also introduces stress CT as a possible solution for diagnosing DRUJ instability from peripheral TFCC lesions.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 94 - 94
1 Jul 2020
Undurraga S Au K Salimian A Gammon B
Full Access

Longstanding un-united scaphoid fractures or scapholunate insufficiency can progress to degenerative wrist osteoarthritis (termed scaphoid non-union advanced collapse (SNAC) or scapho-lunate advanced collapse (SLAC) respectively). Scaphoid excision and partial wrist fusion is a well-established procedure for the surgical treatment of this condition. In this study we present a novel technique and mid-term results, where fusion is reserved for the luno-capitate and triquetro-hamate joints, commonly referred to as bicolumnar fusion. The purpose of this study was to report functional and radiological outcomes in a series of patients who underwent this surgical technique.

This was a prospective study of 23 consecutive patients (25 wrists) who underwent a bicolumnar carpal fusion from January 2014 to January 2017 due to a stage 2 or 3 SNAC/SLAC wrist, with a minimum follow-up of one year. In all cases two retrograde cannulated headless compression screws were used for inter-carpal fixation. The clinical assessment consisted of range of motion, grip and pinch strength that were compared with the unaffected contralateral side where possible. Patient-reported outcome measures, including the DASH and PRWE scores were analysed. The radiographic assessment parameters consisted of fusion state and the appearance of the radio-lunate joint space. We also examined the relationship between the capito-lunate fusion angle and wrist range of motion, comparing wrists fused with a capito-lunate angle greater than 20° of extension with wrists fused in a neutral position.

The average follow-up was 2.9 years. The mean wrist extension was 41°, flexion 36° and radial-ulnar deviation arc was 43° (70%, 52% and 63% of contralateral side respectively). Grip strength was 40 kg and pinch strength was 8.9 kg, both 93% of contralateral side. Residual pain for activities of daily living was 1.4 (VAS). The mean DASH and PRWE scores were 19±16 and 29±18 respectively. There were three cases of non-union (fusion rate of 88%). Two wrists were converted to total wrist arthroplasty and one partial fusion was revised and healed successfully. Patients with an extended capito-lunate fusion angle trended toward more wrist extension but this did not reach statistical significance (P= 0.07). Wrist flexion did not differ between groups. Radio-lunate joint space narrowing progressed in 2 patients but did not affect their functional outcome.

After bicolumnar carpal fusion using retrograde headless screws, patients in this series maintained a functional flexion-extension arc of motion, with grip-pinch strength that was close to normal. These functional outcomes and fusion rates were comparable with standard 4-corner fusion technique. A capito-lunate fusion angle greater than 20° may provide more wrist extension but further investigation is required to establish this effect. This technique has the advantage that compression screws are placed in a retrograde fashion, which does not violate the proximal articular surface of the lunate, preserving the residual load-bearing articulation. Moreover, the hardware is completely contained, with no revision surgery for hardware removal required in this series.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 49 - 49
1 Dec 2016
Lalone E Gammon B Willing R Nishiwaki M Johnson J King G
Full Access

Altered distal radioulnar joint contact (DRUJ) mechanics are thought to cause degenerative changes in the joint following injury. Much of the current research examining DRUJ arthrokinematics focuses on the effect of joint malalignment and resultant degenerative changes. Little is known regarding native cartilage contact mechanics in the distal radioulnar joint. Moreover, current techniques used to measure joint contact rely on invasive procedures and are limited to statically loaded positions. The purpose of this study was to examine native distal radioulnar joint contact mechanics during simulated active and passive forearm rotation using a non-invasive imaging approach.

Testing was performed using 8 fresh frozen cadaveric specimens (6 men: 2 women, mean age 62 years) with no CT evidence of osteoarthritis. The specimens were thawed and surgically prepared for biomechanical testing by isolating the tendons of relevant muscles involved in forearm rotation. The humerus was then rigidly secured to a wrist simulator allowing for simulated active and passive forearm rotation. Three-dimensional (3D) cartilage surface reconstructions of the distal radius and ulna were created using volumetric data acquired from computed tomography after joint disarticulation. Using optically tracked motion data and 3D surface reconstructions, the relative position of the cartilage models was rendered and used to measure DRUJ cartilage contact mechanics.

The results of this study indicate that contact area was maximal in the DRUJ at 10 degrees of supination (p=0.002). There was more contact area in supination than pronation for both active (p=0.005) and passive (p=0.027) forearm rotation. There was no statistically significant difference in the size of the DRUJ contact patch when comparing analogous rotation angles for simulated active and passive forearm motion (p=0.55). The contact centroid moved 10.5±2.6 mm volar along the volar-dorsal axis during simulated active supination. Along the proximal-distal axis, the contact centroid moved 5.7±2.4 mm proximal during simulated active supination.

Using the technique employed in this study, it was possible to non-invasively examine joint cartilage contact mechanics of the distal radioulnar joint while undergoing simulated, continuous active and passive forearm rotation. Overall, there were higher contact area values in supination compared with pronation, with a peak at 10 degrees of supination. The contact centroid moved volarly and proximally with supination. There was no difference in the measured cartilage contact area when comparing active and passive forearm rotation. This study gives new insight into the changes in contact patterns at the native distal radioulnar joint during simulated forearm rotation, and has implications for increasing our understanding of altered joint contact mechanics in the setting of deformity.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 48 - 48
1 Dec 2016
Padmore C Stoesser H Nishiwaki M Gammon B Langohr D Lalone E Johnson J King G
Full Access

Distal radius fractures are the most common fracture of the upper extremity. Malunion of the distal radius is a common clinical problem after these injuries and frequently leads to pain, stiffness loss of strength and functional impairments. Currently, there is no consensus as to whether not the mal-aligned distal radius has an effect on carpal kinematics of the wrist. The purpose of this study was to examine the effect of dorsal angulation (DA) of the distal radius on midcarpal and radiocarpal joint kinematics, and their contributions to total wrist motion.

A passive wrist motion simulator was used to test six fresh-frozen cadaveric upper extremities (age: 67 ± 17yrs). The specimens were amputated at mid humerus, leaving all wrist flexor and extensor tendons and ligamentous structures intact. Tone loads were applied to the wrist flexor and extensor tendons by pneumatic actuators via stainless steel cables. A previously developed distal radius implant was used to simulate native alignment and three DA deformity scenarios (DA 10 deg, 20 deg, and 30 deg). Specimens were rigidly mounted into the simulator with the elbow at 90 degrees of flexion, and guided through a full range of flexion and extension passive motion trials (∼5deg/sec). Carpal motion was captured using optical tracking; radiolunate and capitolunate joint motion was measured and evaluated.

For the normally aligned radius, radiolunate joint motion predominated in flexion, contributing on average 65.4% (±3.4). While the capitolunate joint motion predominated in extension, contributing on 63.8% (±14.0). Increasing DA resulted in significant alterations in radiolunate and capitolunate joint kinematics (p<0.001). There was a reduction of contribution from the capitolunate joint to total wrist motion throughout flexion-extension, significant from 5 degrees of wrist extension to full extension (p = 0.024). Conversely, the radiolunate joint increased its contribution to motion with increasing DA; significant from 5 degrees of wrist extension to full extension as the radiolunate and capitolunate joint kinematics mirrored each other. A DA of 30 degrees resulted in an average radiolunate contribution of 72.6% ± 7.7, across the range of motion of 40 degrees of flexion to 25 degrees of extension.

The results of our study for the radius in a normal anatomic alignment are consistent with prior investigators, showing the radiocarpal joint dominated flexion, and the midcarpal joint dominated extension; with an average 60/40 division in contributions for the radiocarpal in flexion and the midcarpal in extension, respectfully. As DA increased, the radiocarpal joint provided a larger contribution of motion throughout flexion and extension. This alteration in carpal kinematics with increased distal radius dorsal angulation may increase localised stresses and perhaps lead to accelerated joint wear and wrist pain in patients with malunited distal radial fractures.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 47 - 47
1 Dec 2016
Stoesser H Padmore C Nishiwaki M Gammon B Langohr G Lalone E Johnson J King G
Full Access

Wrist motion is achieved primarily via rotation at the radiocarpal and midcarpal joints. The contribution of each carpal bone to total range of motion has been previously investigated, although there is no consensus regarding the influence of each structure to global wrist motion. The objective of this comprehensive in-vitro biomechanical study was to determine the kinematics of the capitate, scaphoid and lunate during unconstrained simulated wrist flexion-extension. In addition, this study examined the effect of motion direction (i.e. flexion or extension) on the kinematics and contribution of the carpal bones.

Seven fresh frozen cadaveric upper limb specimens (age: 67±18 yrs) were amputated mid-humerus, and the wrist flexors/extensors were exposed and sutured at their musculotendinous junctions. Each specimen was mounted on a wrist motion simulator in neutral forearm rotation with the elbow at 90° flexion. Passive flexion and extension motion of the wrist was simulated by moving a K-wire, inserted into the third metacarpal, through the flexion/extension motion arc at a speed of ∼5 mm/sec under muscle tone loads of 10N. Carpal kinematics were captured using optical tracking of bone fixated markers. Kinematic data was analysed from ±35° flexion/extension.

Scaphoid and lunate motion differed between wrist flexion and extension, but correlated linearly (R‸2=0.99,0.97) with capitate motion. In wrist extension, the scaphoid (p=0.03) and lunate (p=0.01) extended 83±19% & 37±18% respectively relative to the capitate. In wrist flexion, the scaphoid (p=1.0) and lunate (p=0.01) flexed 95±20% and 70±12% respectively relative to the capitate. The ratio of carpal rotation to global wrist rotation decreased as the wrist moved from flexion to extension. The lunate rotates on average 46±25% less than the capitate and 35±31% less than the scaphoid during global wrist motion (p=0.01). The scaphoid rotates on average 11±19% less than the capitate during wrist flexion and extension (p=0.07). There was no difference in the contribution of carpal bone motion to global wrist motion during flexion (p=0.26) or extension (p=0.78).

The capitate, lunate and scaphoid move synergistically throughout planar motions of the wrist. Our study found that both the scaphoid and lunate contributed at a greater degree during wrist flexion compared to extension, suggesting that the radiocarpal joint plays a more critical role in wrist flexion. Our results agree with previous studies demonstrating that the scaphoid and lunate do not contribute equally to wrist motion and do not function as a single unit during planar wrist motion. The large magnitude of differential rotation observed between the scaphoid and lunate may be responsible for the high incidence of scapholunate ligament injuries relative to other intercarpal ligaments. An understanding of normal carpal kinematics may assist in developing more durable wrist arthroplasty designs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 53 - 53
1 Nov 2016
Stoesser H Padmore C Nishiwaki M Gammon B Langohr G Lalone E Johnson J King G
Full Access

Wrist motion is achieved primarily via rotation at the radiocarpal and midcarpal joints. The contribution of each carpal bone to total range of motion has been previously investigated, although there is no consensus regarding the influence of each structure to global wrist motion. The objective of this comprehensive in-vitro biomechanical study was to determine the kinematics of the capitate, scaphoid and lunate during unconstrained simulated wrist flexion-extension. In addition, this study examined the effect of motion direction (i.e. flexion or extension) on the kinematics and contribution of the carpal bones.

Seven fresh frozen cadaveric upper limb specimens (age: 67±18 yrs) were amputated mid-humerus, and the wrist flexors/extensors were exposed and sutured at their musculotendinous junctions. Each specimen was mounted on a wrist motion simulator in neutral forearm rotation with the elbow at 90° flexion. Passive flexion and extension motion of the wrist was simulated by moving a K-wire, inserted into the third metacarpal, through the flexion/extension motion arc at a speed of ∼5 mm/sec under muscle tone loads of 10N. Carpal kinematics were captured using optical tracking of bone fixated markers. Kinematic data was analysed from ±35° flexion/extension.

Scaphoid and lunate motion differed between wrist flexion and extension, but correlated linearly (R^2=0.99,0.97) with capitate motion. In wrist extension, the scaphoid (p=0.03) and lunate (p=0.01) extended 83±19% & 37±18% respectively relative to the capitate. In wrist flexion, the scaphoid (p=1.0) and lunate (p=0.01) flexed 95±20% and 70±12% respectively relative to the capitate. The ratio of carpal rotation to global wrist rotation decreased as the wrist moved from flexion to extension. The lunate rotates on average 46±25% less than the capitate and 35±31% less than the scaphoid during global wrist motion (p=0.01). The scaphoid rotates on average 11±19% less than the capitate during wrist flexion and extension (p=0.07). There was no difference in the contribution of carpal bone motion to global wrist motion during flexion (p=0.26) or extension (p=0.78).

The capitate, lunate and scaphoid move synergistically throughout planar motions of the wrist. Our study found that both the scaphoid and lunate contributed at a greater degree during wrist flexion compared to extension, suggesting that the radiocarpal joint plays a more critical role in wrist flexion. Our results agree with previous studies demonstrating that the scaphoid and lunate do not contribute equally to wrist motion and do not function as a single unit during planar wrist motion. The large magnitude of differential rotation observed between the scaphoid and lunate may be responsible for the high incidence of scapholunate ligament injuries relative to other intercarpal ligaments. An understanding of normal carpal kinematics may assist in developing more durable wrist arthroplasty designs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 52 - 52
1 Nov 2016
Ng J Nishiwaki M Gammon B Athwal G King G Johnson J
Full Access

Fracture or resection of the radial head can cause unbalance and long-term functional complications in the elbow. Studies have shown that a radial head excision can change elbow kinematics and decrease elbow stability. The radial head is also important in both valgus and varus laxity and displacement. However, the effect of radial head on ulnohumeral joint load is not known. The objective of this experimental study was to compare the axial loading produced at the ulnohumeral joint during active flexion with and without a radial head resection.

Ten cadaveric arms were used. Each specimen was prepared and secured in an elbow motion simulator. To simulate active flexion, the tendons of the biceps, brachialis, brachioradialis, and triceps were attached to servo motors. The elbow was moved through a full range of flexion. To quantify loads at the ulnohumeral joint, a load cell was implanted in the proximal ulna. Testing was conducted in the intact then radial head resected case, in supination in the horizontal, vertical, varus and valgus positions.

When comparing the average loads during flexion, the axial ulnar load in the horizontal position was 89±29N in an intact state compared to 122±46N during radial head resection. In the vertical position, the intact state produced a 67±16N load while the resected state was 78±23N. In the varus and valgus positions, intact state resulted in loads of 57±26N and 18±3N, respectively. Conversely, with a radial head resection, varus and valus positions measured 56±23N and 54±23N loads, respectively. For both joint configurations, statistical differences were observed for all flexion angles in all arm positions during active flexion (p=0.0001). When comparing arm positions and flexion angle, statistical differences were measured between valgus, horizontal and vertical (p<0.005) except for varus position (p=0.64).

Active flexion caused a variation in loads throughout flexion when comparing intact versus radial head resection. The most significant variation in ulnar loading occurred during valgus and horizontal flexion. The vertical and varus position showed little variation because the position of the arm is not affected by the loss of the radial head. However, in valgus position, the resected radial head creates a void in the joint space and, with gravity, causes greater compensatory ulnar loading. In the horizontal position, the forearm is not directly affected by gravitational pull and cannot adjust to counterbalance the resected radial head, therefore loads are localised in the ulnohumeral joint. These findings prove the importance of the radial head and that a radial head resection can overload the ulnohumeral side.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 16 - 16
1 Oct 2012
Smith E Al-Sanawi H Gammon B St. John P Pichora D Ellis R
Full Access

Primary internal fixation of uncomplicated scaphoid fractures is growing in popularity due to its advantages over conventional cast fixation. Performing the procedure percutaneously reduces the risk of infection and soft tissue damage, but can be tricky because of the small size and complex three-dimensional (3D) shape of this bone. Computer-assisted navigation has been an invaluable tool in other pin insertion procedures.

This in-vitro study aimed to evaluate two different rendering techniques for our navigation interface: (i) 3D volume rendering of the CBCT image to show digitally-reconstructed radiographs of the anatomy, and (ii) volume-slicing, analogous to CT-images.

As the shape of the scaphoid is highly variable, a plastic model of the wrist was constructed in order to provide consistency that would not be possible in a cadaver-based study. The plastic model featured a removable scaphoid such that a new one was replaced between trials. Three surgeons each performed eight trials using each of the two navigated techniques (yielding a total of 48 trials for analysis). Central placement of scaphoid fixation has been linked with mechanical stability and improved clinical outcomes, thus the surgical goal was to place a K-wire to maximise both depth from the surface and length of the drill path. The wire was drilled through the scaphoid, from distal to proximal, allowing for post-trial analysis of the drill path. A ceiling-mounted OptoTrak Certus camera (Northern Digital Inc., Canada) and a floor-mounted isocentric 3D CBCT C-arm (Innova 4100, GE Healthcare, France) permitted a registration transformation between the tracking and imaging systems to be computed preoperatively, before each trial, using a custom calibration device. Optical local coordinate reference bodies were attached to the wrist model and a custom drill guide for tracking with the Certus camera. During each trial, a 3D spin image of the wrist model was acquired, and rendered according to the technique under study.

For 3D volume rendering, the spin image was rendered as a digitally-reconstructed radiograph (DRR) that could be rotated in three dimensions. In the planning phase, the surgeon positioned a desired drill path on the images. Anterior-posterior and lateral views of the 3D volume rendering were used for navigation during the drilling phase. The real-time orientation of the drill guide was shown relative to these images and the plan on an overhead.

For volume-sliced (VS) navigation, the spin image was volume-rendered and sliced along the principal planes (axial, coronal, sagittal) for planning. A slider interface allowed the surgeon to scroll through the slices in each of the planes, as if they were looking at individual CT slices. Once the desired drill path was positioned, the volume-sliced views were reconfigured to show slices along the oblique planes of the planned path for navigation.

Following all trials, model scaphoids with wire intact were imaged using CT with a slice thickness of 0.625 mm. The CT series were segmented and used to construct 3D digital models of the wire and drilled scaphoid. Algorithms were developed to determine the minimum distance from the centerline of the wire and the scaphoid surface, and to compute the length of the drill path. Screw breach should be avoided as it disrupts the articular surface and may lead to a sequela of cartilage deterioration and osteoarthritic changes. The shortest distance measure was extrapolated to assess whether a standard fixation screw (Accutrak Mini, 1.78 mm radius) would have breached the scaphoid surface. There were three screw breaches noted in the 3D DRR trials, while only one occurred using volume-slicing. The minimum distance from the centerline of the wire to the scaphoid surface can also be thought of as a “safe zone” for screw breach. Although no difference in the mean distance (μ) was noted between groups (μDRR = 2.3 mm, μVS = 2.2 mm), the standard deviation (σ) was significantly higher for the DRR trials (σDRR = 0.50 mm, σVS = 0.37 mm, p < 0.1), suggesting a higher reliability of central placement using VS for navigation. In contrast, the length of the drill paths were significantly longer for the DRR trials (μ = 28.7 mm, σ = 0.66 mm) than for VS-navigation (μ = 28.3 mm, σ = 0.62 mm) at p < 0.1.

The surgical goal was to pick a path that maximised both the length of the path, as well as the minimum distance from the scaphoid surface. Algorithms were developed to find the paths that would maximise: (i) the length and (ii) the distance from the surface of the model scaphoid used in this study. The maximum possible length was 29.8mm (with a minimum distance of 2.2mm from the scaphoid surface), and the maximum distance was 3.3mm (with a length of 27.5mm). Therefore, the set of optimal drill paths had length > 27.5 mm, and distance > 2.8 mm. Of the DRR-navigated trials, 11 were below the minimum optimal depth, and only one trial was below the optimal length; 13 of the 24 trials (54%) were of both optimal length and depth. Of the VS-navigated trials, nine were below the minimal optimal distance, and four were below the minimum optimal length; 11 out of 24 trials (46%) were within both the optimal length and depth.

From this comparative study, we conclude that VS-navigation was superior in locating a central location for the fixation wire, while DRRs were superior in maximising the depth of the drill path. Thus, we propose a hybrid interface, incorporating both volume-slicing and DRRs, in order to maximise the effectiveness of navigation for percutaneous scaphoid pinning.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 52 - 52
1 Sep 2012
Al-Sanawi H Gammon B Sellens RW John PS Smith EJ Ellis RE Pichora DR
Full Access

Purpose

Primary internal fixation of uncomplicated scaphoid fractures offers many advantages compared to conventional casting. However, ideal fixation placement along the central scaphoid axis can be challenging, especially if the procedure is performed percutaneously. Because of the lack of direct visualization, percutaneous procedures demand liberal use of imaging, thereby increasing exposure to harmful radiation.

It has been demonstrated that computer-assisted navigation can improve the accuracy of guidewire placement and reduce X-ray exposure in procedures such as hip fracture fixation. Adapting the conventional computer-assist paradigm, with preoperative imaging and intraoperative registration, to scaphoid fixation is not straightforward, and thus a novel tactic must be conceived.

Method

Our navigation procedure made use of a flatpanel C-arm (Innova, GE Healthcare) to obtain a 3D cone-beam CT (CBCT) scan of the wrist from which volumetrically-rendered images were created. The relationship between the Innova imager and an optical tracking system (OptoTrak Certus, Northern Digital Inc.) was calibrated preoperatively so that an intraoperatively-acquired image could be used for real-time navigation. Optical markers fitted to a drill guide were used to track its orientation, which was displayed on a computer monitor relative to the wrist images for navigation.

Randomized trials were conducted comparing our 3D navigated technique to two alternatives: one using a standard portable C-arm, and the other using the Innova flatpanel C-arm with 2D views and image intensification. A model forearm with an exchangeable scaphoid was constructed to provide consistency between the trials. The surgical objective was to insert a K-wire along the central axis of a model scaphoid.

An exposure meter placed adjacent to the wrist model was used to record X-ray exposure. Procedure time and drill passes were also noted. CT scans of the drilled scaphoids were used to determine the shortest distance from the drill path to the scaphoid surface.