Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
Bone & Joint Research
Vol. 13, Issue 3 | Pages 91 - 100
1 Mar 2024
Yamamoto Y Fukui T Sawauchi K Yoshikawa R Takase K Kumabe Y Maruo A Niikura T Kuroda R Oe K

Aims

Continuous local antibiotic perfusion (CLAP) has recently attracted attention as a new drug delivery system for orthopaedic infections. CLAP is a direct continuous infusion of high-concentration gentamicin (1,200 μg/ml) into the bone marrow. As it is a new system, its influence on the bone marrow is unknown. This study aimed to examine the effects of high-concentration antibiotics on human bone tissue-derived cells.

Methods

Cells were isolated from the bone tissue grafts collected from six patients using the Reamer-Irrigator-Aspirator system, and exposed to different gentamicin concentrations. Live cells rate, apoptosis rate, alkaline phosphatase (ALP) activity, expression of osteoblast-related genes, mineralization potential, and restoration of cell viability and ALP activity were examined by in vitro studies.


Bone & Joint Research
Vol. 7, Issue 2 | Pages 139 - 147
1 Feb 2018
Takahara S Lee SY Iwakura T Oe K Fukui T Okumachi E Waki T Arakura M Sakai Y Nishida K Kuroda R Niikura T

Objectives

Diabetes mellitus (DM) is known to impair fracture healing. Increasing evidence suggests that some microRNA (miRNA) is involved in the pathophysiology of diabetes and its complications. We hypothesized that the functions of miRNA and changes to their patterns of expression may be implicated in the pathogenesis of impaired fracture healing in DM.

Methods

Closed transverse fractures were created in the femurs of 116 rats, with half assigned to the DM group and half assigned to the control group. Rats with DM were induced by a single intraperitoneal injection of streptozotocin. At post-fracture days five, seven, 11, 14, 21, and 28, miRNA was extracted from the newly generated tissue at the fracture site. Microarray analysis was performed with miRNA samples from each group on post-fracture days five and 11. For further analysis, real-time polymerase chain reaction (PCR) analysis was performed at each timepoint.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 23 - 23
1 Feb 2017
Iguchi H Mitsui H Kobayashi M Nagaya Y Goto H Nozaki M Murakami S Shibata Y Fukui T Okumura T Otsuka T
Full Access

Introduction

Since 1989 we have been using custom lateral-flare stems. Using this stem, its lateral flare can produce high proximal fit and less fit in distal part. Applying this automatic designing software to the average femoral geometries, we can make off the shelf high proximal fit stem (Revelation ®). Putting the off the shelf stem, the original center of the femoral heads were well reproduced. But in DDH cases, severe deformities around hip sometimes make complicated difficulty for better functional reconstruction. They are high hip center such as Crowe II-IV, shortening of the femoral neck, high anteversion etc. DDH cases are well known to have higher anteversion than non DDH cases. There would be no definite explanations for it. The high anteversion would not always be harmful for the preoperative patients. But in some cases, osteophytes are observed at posterior side of the femoral head which make another sphere with different centre. We can guess that the patient's biomechanics had not been matched with the original anteversion. Then posterior osteophytes can correct inappropriate anteversion (self-reduction.) (Fig.1) In those patients, reduction of the anteversion by putting stems twisted into the canal or using modular stems are sometimes done by the surgeons' decision.

Younger DDH cases can also be treated with THA, because of the complicated deformities or biomechanical disorders. Short stems are expected to reduce operative invasion and stress shielding then can reserve bone quality and quantity. From these point of view to improve the understanding of the characteristics of the DDH anteversion, and design a DDH oriented short stem could be one of good solution for those cases.

Method

For the better understanding of the high anteversion 57 femora (mean anteversion: 34.4 deg.) were analyzed slice by slice. The direction of femoral head centre, lesser trochanter (LTR), linea aspera (aspera) just below LTR, aspera in the middle of the femur and aspera between the last 2 sections. All of the directions were assessed from PC line

To clarify the meaning of the head osteophytes, 35 operated cases were analyzed the extent of the head osteophytes.

According to the results, a DDH oriented short stem was designed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 45 - 45
1 May 2016
Iguchi H Mitsui H Kobayashi M Nagaya Y Goto H Nozaki M Watanabe N Shibata Y Shibata Y Fukui T Joyo Y Otsuka T
Full Access

Introduction

In DDH cases often have high anteversion. They also often have high hip center. THA for those cases sometimes requires subtrochanteric derotational/shortening osteotomy. To achieve good results of the surgery, accurate preoperative planning based on biomechanics of the high anteversion cases, method for accurate application of the plan, and stable fixation are very important. At ISTA 2008, we have reported that the location of the anteversion exist several centimeters below the lesser trochanter. Independently from the extent of anteversion, femoral head, grater trochanter, and lesser trochanter are aligned in the same proportion. We have also reported in 2007, in improper high anteversion cases, many cases grow osteophytes posterior side of femoral head to reduce it functionally. In 2014, we reported about development of the stem for subtrochanteric osteotomy. (ModulusR)[Fig.1] In the present study, we established systematic planning way for estimate proper derotation and shortening and apply it for the surgery.

Methods

Leg alignment during walking were well observed. According to the CT, 3D geometry of the femur, anteversion in hip joint and its compensation by the osteophyte, and knee rotation were measured. It was divided into proximal part and distal part at several centimeter below the lesser trochanter. Adequate hip local anteversion was determined by local original anteversion – compensation if IR-ER can be done. Keeping that anteversion for the proximal part, distal part was rotated as knee towards front. Thus derotation angle was decided. Using 3D CAD (Magics®) proper size of Modulus R was selected and overlapping with canal was extracted then its center of gravity was calculated. This level is decided as the height of osteotomy to obtain equal fixation to both proximal and distal part.[Fig.2] If the derotation angle is less than 15 degree, modular neck adjustment was selected first. By trial reduction and motion test, according to the instability osteotomy was performed. In the high hip center cases, original hip center was reconstructed. Shortening length was determined not to make leg elongation more than 3cm. ModulusR were used for the replacement and fixation of the osteotomy.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 56 - 56
1 Jan 2016
Iguchi H Mitsui H Murakami S Kobayashi M Nagaya Y Nozaki M Goto H Watanabe N Shibata Y Shibata Y Fukui T Otsuka T
Full Access

Introduction

Since 1989, we have been developing lateral flare stem. The concept of lateral flare stem is to deliver proximal part big enough to fill the proximal cavity that most of the cement stems can fill and most of the cementless stems cannot. Also having distal part polished, much less distal load transfer occurs than cement stem. Thus, we can expect high proximal load transfer to prevent stress shielding. To deliver lateral flare stem, straight insertion path cannot be available, as proximal lateral part to fill inside the greater throchanter collides to the greater trochanter. So 3-Dimension insertion path was calculated to deliver that part through the narrow made by neck osteotomy. The first generation of the lateral flare stem was custom made. The second generation was designed as an off-the-shelf stem from what we have learned by the experience of custom stems. With the third generation, the stem was shortened to achieve more proximal load transfer.

Direct Anterior Approach (DAA) developed by Judet is one of less invasive hip approach. With a stem with straight insertion path, the extended line of proximal femoral axis should come out of the skin. To achieve this position, proximal end of the femur has to be fully pulled up. (Fig.1) Some of the cases would be able to be lifted up but some have difficulty. Using lateral flare stem with curved 3 dimensional insertion path, even the axis extension does not come out of the skin, it would be expected to be inserted. In the present study, 3D insertion path of the lateral flare short stem for DAA was analyzed.

Materials and methods

Preoperative CAT scan data were transferred to STL data by Mimics®. The procedures after that were done by Magics®. First, neck osteotomy was done, externally rotated, and mild extension that doesn't make the axis come out of the skin was added. Then insertion path was verified keeping the stem attached medial sidewall of the canal (Fig. 2). In actual case, skin translation and pelvis rotation was assessed by 3D scanner. (Fig. 3)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 57 - 57
1 Jan 2016
Iguchi H Mitsui H Murakami S Kobayashi M Nagaya Y Nozaki M Goto H Watanabe N Shibata Y Shibata Y Fukui T Otsuka T
Full Access

Introduction

During THA in lateral position, keeping accurate lateral position is very important for obtaining good cup position. We normally use two kinds of hip positioner, but sometimes we can only use universal positioner provided with operational table. The pelvic tilt can be changed by surgical procedures such as traction, dislocation, reduction and so forth. In the present study, pre-op and post-op pelvic tilt was assessed using Kinect (Xbox 360′s sensor) as 3D scanner.

Materials and Methods

As a 3D scanner, “Kinect®” was used (Fig. 1) with scanning software “Artec Studio 9 ®”. First, accuracy of the scanning system was validated, then 6 postero-lateral approach hip replacement with lateral position surgery cases (Fig.2) (1 male and 5 female, average 55.5 y.o., average BMI 27.6, IMP® positioner: 3 cases, Kyocera positioner: 2 cases, universal fixator provided with surgical table: 1 case), one direct anterior approach case, and one supine antero lateral case (Fig. 3) were scanned pre and post operatively. Pelvic tilts were assessed using tableside rails or edges of positioner that is tightly fixed to the table, as the reference.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 55 - 55
1 Jan 2016
Iguchi H Mitsui H Murakami S Kobayashi M Nagaya Y Nozaki M Goto H Watanabe N Shibata Y Shibata Y Fukui T Otsuka T
Full Access

Introduction

In THA of DDH cases, sometimes shortening and/or derotational subtrochanteric osteotomy is required, for cases with high hip center and/or high anteversion. Initial fixation is one of the most important problems after subtrochanteric osteotomy. To prevent rotational displacement V-osteotomy or step osteotomy is often used. Even though until the osteotomy part unites, additional fixation is required. When a stem with distal load transfer was used body weight can be transferred to healthy part, so early full weight bearing should be expected. However, the muscles around hip joint can pull up proximal part, so it would be possible osteotomy part to be split. When a stem with proximal load transfer, body weight would be loaded on non united osteotomy part. So full weight bearing could sometimes be postponed. A stem that has both proximal and distal load transfer, and has facility for prevent rotation, those situations would possibly be simply solved.

Lima (Italy) has a proximal load transfer conical stem with fins “Modulus” and a distal load transfer conical stem “Revision.” Combining these two stems, a stem as explained prior was designed. In the present study, applicability of the stem for cases such as subtrochanteric osteotomy was assessed.

Materials and Methods

The stem geometry data were provided by the maker. Forty CAT scan DICOM data, 12 male, 28 female, 58+/−13.8 Y.O. were transferred to STL geometry data using Mimics®. Then using Magics® fit studies were done. For each femur, most suitable size of conventional “Modulus” and double conical stem “Modulus R” were selected to have tight fit making greater trochanter top height as head center height, then the area where stem core attaches to the inside surface of the canal were determined.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 140 - 140
1 Jan 2016
Fukui T Iguchi H Shibata Y
Full Access

Introduction

For the total hip cases with severe bone defect, using acetabular reinforcement plate is one of effective method. But the shape of every defect is different. So it is very important to make it into proper shape. It would be not only time consuming but also the procedure requires many times trial insertion through the muscle which can be a cause big damage on it. To reduce the time and the damage, we have manufactured a chemical wood model for each case and shaped each acetabular reinforce plates.

Materials and Methods

Three total hip cases, one primary case of rheumatoid arthritis with big bone absorption and 2 revision cases with big bone absorption were operated with acetabular reinforcement plate (LIMA Italy) shaped on their pelvic chemical wood model. Using Mimics®, CAT scan DICOM data were transferred STL CAD data. Then using Magics® chemical wood model was designed and manufactured by a compact CNC machine. Then each plate was bent and fitted for each defect 3-Dimensionally.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 23 - 23
1 Apr 2013
Kawakami Y Ii M Kawamoto A Matsumoto T Mifune Y Shoji T Fukui T Kuroda R Kurosaka M Asahara T
Full Access

Introduction

Failures in fracture healing are mainly caused by a lack of neovascularization. We have previously demonstrated that G-CSF-mobilized peripheral blood (GM-PB) CD34+ cells, an endothelial progenitor enriched cell population, contributed to fracture healing via vasculogenesis and osteogenesis. We postulated the hypothesis that local transplantation of culture expanded bone marrow (cEx-BM) CD34+ cells could exhibit therapeutic potential for fracture healing.

Materials

BM CD34+ cells were cultured in specific medium with 5 growth factors for 1week. A reproducible model of femoral fracture was created in nude rats with periosteum cauterization, which leads to nonunion at 8 weeks post-fracture. Rats received local administration of the following cells or PBS alone(1)cEx-BM, (2)BM, (3)GM-PB CD34+ cells or (4)PBS.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 90 - 90
1 Apr 2013
Kawakami Y Matsumoto T Ii M Kawamoto A Kuroda R Mifune Y Shoji T Fukui T Kurosaka M Asahara T
Full Access

Introduction

The therapeutic potential of hematopoietic stem cells for fracture healing has been demonstrated with mechanistic insight of vasculogenesis and osteogenesis enhancement. Lnk has recently been proved an essential inhibitory signaling molecule in SCF-c-Kit signaling pathway for stem cell self-renewal demonstrating enhanced hematopoietic and osteogenic reconstitution in Lnk-deficient mice. We investigated the hypothesis that down regulation of Lnk enhances regenerative response via vasculogenesis and osteogenesis in fracture healing.

Methods

A reproducible model of femoral fracture was created in mice. Immediately after fracture creation, mice received local administration of the following materials with AteloGene, 10μM (1)Lnk siRNA, (2)control siRNA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 73 - 73
1 Sep 2012
Iguchi H Watanabe N Tawada K Hasegawa S Kuroyanagi G Murase A Murakami S Fukui T Kobayashi M Fetto J
Full Access

Introduction

To obtain a better range of motion and to reduce the risk of dislocation, neck and cup anteversion are considered very important. Especially for the reduction of the risk of dislocation, the mutual alignment between neck and cup anteversion (combined anteversion) is often discussed. A surgeon would compare the neck direction to the calf direction with the knee in 90 degrees flexion. When an excessive anteversion was observed, the neck anteversion would be reduced using modular neck system or setting the stem a little twisted inside the canal with the tradeoff of the stem stability. Another choice would be the adjustment of cup alignment. Combined anteversion is defined the summation of cup anteversion in axial plane and stem anteversion in axial plane. But in realty the impingement occurs with 3 dimensional relationships between neck and cup with very complicated geometries. In that meaning, the definition of the angles could be said ambiguous too. The bowing of the femur also makes the relationships more complicated. Upon those backgrounds, we have been performing 3D preoperative planning for total hip arthroplasty on every case. In the present study, in vivo position of the stem in each case was determined then the anteversion observed on surgical view and anteversion around femoral mechanical axis are compared using 3D CAD software.

Materials and Methods

Ten recent cases from our hip arthroplasty with 3D preoperative planning were reviewed for this purpose. The bone geometries were obtained from CAT scans with very low X-ray dose using Mimics® (Materialize, Belgium). Preoperative planning for Revelation stem® (DJO, USA) was performed using Mimics® (Materialize, Belgium). Femoral mechanical axis was defined as a line between center of femoral head and the middle point of medial and lateral epicondyle of the femur. Then mechanical anteversion is assessed from posterior condylar line. On the other hand, the calf was rotated 90 degrees around epiconlylar axis of each femur, and in vivo stem position was estimated then, stem axis was aligned perpendicular to the view. The anteversion in the surgical view was assessed from that view as the angle toward the calf. (Fig. 1) Using in vivo stem alignment, the impingement angle was also assessed.