Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 152 - 152
1 May 2016
Zhu M Chen J Chong H Yew A Foo L Chia S Lo N Yeo S
Full Access

Objective

Patient-specific instrumentation (PSI) is a novel technique in total knee arthroplasty (TKA) which potentially permits more accurate alignment of the components; however, there is no consensus in literature regarding the accuracy and reliability of PSI as many studies have shown controversial and inconsistent results of various PSI systems. A 24-month follow-up study was carried out to compare perioperative clinical outcomes, radiological limb alignment and component positioning, as well as functional outcomes following TKA between PSI and conventional instrumentation (CI).

Methods

During September 2011 and August 2012, 90 consecutive patients were scheduled to undergo unilateral TKA with either PSI or CI. TruMatch® Personalised Solutions was used in this study, and a senior surgeon performed all operations. Patients were clinically assessed before, 6-month and 24-month after surgery.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 411 - 411
1 Nov 2011
Ranawat A Koob T Koenig J Cooper H Foo L Potter H Ranawat C
Full Access

Introduction: Computer-based wear analysis is currently the most accurate method for determining the in vivo wear rates of polyethylene liners during total hip arthroplasty. MRI of a total hip is emerging as the best method for determining the intra-articular volume of particulate debris. The purpose of this study is to determine if there is a correlation between polyethylene wear and the development of particle load in patients with highly crosslinked (HXLP) liners.

Materials and Methods: 20 well-functioning total hips (7 metal heads against HXLP liners and 13 ceramic heads against HXLP liners) in 18 young active individuals were analyzed using the following criteria: femoral head penetration of the liner was measured by Roman (ROntgen Monographic ANalysis) software and particulate load was calculated by MRI criteria as described by Potter et al. Clinical and radiographic analyses were performed using HSS, WOMAC, and criteria defined by DeLee, Charnley, and Engh. The average age of the patients was 57 (Range 45–67) and average follow-up was 1.6 y (range 1.0 – 3.0 y).

Results: All implants appeared well osteointegrated with no radiographic evidence of osteolysis. All patients had well-functioning total hips with a greater than one mile daily walking tolerance. A trend towards correlation was observed between increased polyethylene wear and increased particulate volumes. Average HXLP wear was 0.03 mm (range −0.19 to 0.27 mm) and average particle volume was 841 (range 6951 to 0). One patient in particular recorded 0.27 mm of polyethylene wear, mild particle disease and a particle disease volume of 3321 at 1.6 years follow-up. However, statistical significance could not be achieved with these data points.

Conclusions: There appears to be a relationship between polyethylene wear as measured by computer-based systems and particulate volume as measured by MRI. Limitations of the current methodology include the inability of computer-based systems to detect precise levels of minimal wear with HXLP liners, and the highly sensitive MRI images which may be detecting more than just wear debris.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 88 - 88
1 Mar 2010
Cooper H Ranawat A Koob T Foo L Potter H Ranawat C
Full Access

The ability of optimised MRI to detect periarticular bony and soft tissue pathology in the post-arthroplasty hip is well documented; specifically it is able to detect early stages of particle disease well before osteolysis is apparent on radiographs. This is a prospective study designed to utilise MRI for the detection of early particle disease in asymptomatic patients after total hip arthroplasty.

Patients who underwent routine non-cemented THA were recruited from three different groups: metal-on-polyethylene, ceramic-on-ceramic, and ceramic-on-polyethylene bearing surfaces. All patients enrolled underwent optimised MRI one to three years (mean 1.7) after the index procedure. Images were analyzed for the presence of synovial proliferation, fibrous membrane formation or osteolysis. Particle disease was correlated with type of bearing surface, pain, activity level, patient satisfaction, and clinical outcome scales.

Thirty-two hips have been enrolled in the study to date. Early particle disease was seen in two of seven metal-on-polyethylene hips (29%), four of twelve ceramic-on-ceramic hips (33%), and six of thirteen ceramic-on-polyethylene hips (46%). Focal osteolysis was seen in one patient with a ceramic-on-polyethylene hip. These values were not statistically significant among the groups. The presence of early particle disease did not correlate with pain, activity level, patient satisfaction, or other clinical outcome scales.

This study allows patients with a well functioning total hip arthroplasty to be prospectively followed with MRI. It is the first to document the natural history of particle disease in vivo and considerably enhances our knowledge of periarticular pathology in the post-operative hip. These results demonstrate early particle disease is relatively common yet asymptomatic; they do not demonstrate advantages of any bearing couple over another for protection against particle disease at short-term follow-up.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 160 - 160
1 Mar 2010
Cooper H Ranawat A Koob T Foo L Potter H Ranawat C
Full Access

We previously reported no clinical differences in short-term results in 26 patients that underwent fixed-bearing (FB) total knee arthroplasty in one knee followed by a rotating-platform (RP) version of the same implant in the contralateral knee at a later date. This study presents intermediate-term results in this unique cohort and uses optimised MRI for detection of particle disease in both knees.

Patients from the original series were asked to complete questionnaires regarding both knees. In addition, both knees were evaluated with optimised MRI, which has been shown to be useful in evaluating early particle disease and osteolysis before its appearance on radiographs.

Nine patients have been enrolled to date. At an average follow-up of 8.3 years for the FB side and 6.5 years for the RP side, no significant differences were found with respect to knee preference, pain, or overall satisfaction. Seven patients underwent MRI studies of both knees. Two FB knees demonstrated a massive intracapsular burden of particle disease (average 3066 mm3) with reactive synovitis, compared to no obvious particle disease in any RP knees. Osteolysis was seen around the femur in one FB knee and around the patella in two FB knees, compared to only around a single patella in the RP side.

RP knees continue to demonstrate excellent patient satisfaction that is comparable to clinical results of the FB design; however, FB knees demonstrate higher rates of particle disease and early osteolysis on MRI. This is the first study to demonstrate in vivo advantages of RP over FB designs. It is unclear whether this is due to the slightly longer follow-up period for the FB knees or a decreased wear rate in the RP design; these differences may become apparent with longitudinal follow-up.