Shillington M Farmer G
Full Access

The LCS RPS knee system is based on the successful LCS mobile bearing prosthesis, and has been introduced with the intention of improving post-operative knee flexion. The aim of this study is to report a high incidence of significant patellofemoral crepitus when this prosthesis is used without patella resurfacing. A successful arthroscopic technique to treat this complication will be described.

We present a retrospective review of a single surgeon series of LCS RPS knee arthroplasty. All procedures were performed using a standard technique with cemented components. The patella was not resurfaced in any of the presented cases. The knee society score, patellofemoral score (Baldini et al, 2006), BMI, range of motion, and post-operative radiographs were obtained for all patients. In addition the presence of patellofemoral crepitus was assessed and rated as either none, mild (for limited ROM), moderate (throughout entire ROM), or severe(catching/clunk). An arthroscopic technique to treat this complication was developed.

A total of 56 patients were reviewed at a mean follow-up of 16 months (range 9–22). The mean age at time of operation was 70 (range 50–87), and mean BMI was 29 (range 18–42). A lateral release was performed in 7 cases (12%). Mean knee society score was 77 (range 35–92), patellofemoral score 73 (range 25–100), and ROM 115 degrees (range 85–135). Significantly, patellofemoral crepitus was severe in 12 (21%) patients, moderate in 21 (37%), mild in 15 (26%), and absent in 9 (16%). In 4 patients arthroscopic resection of the proximal pole of the patella has resulted in complete resolution of severe crepitus with increases in patellofemoral (mean 25) and knee society (mean 7) scores, and, ROM (mean 15 degrees). One of these patients at 6 month follow-up has reported return of moderate crepitus. Similar resolution of crepitus has been seen in 3 cases which were revised to resurface the patella. As part of this ongoing study a non-randomised comparison group who received patellar resurfacing at the primary procedure has produced no cases of moderate or severe crepitus.

In conclusion patella resurfacing is required when using the LCS RPS prosthesis to prevent an unacceptably high rate of moderate to severe patellofemoral crepitus. Both arthroscopic patelloplasty and revision to resurface the patella have resulted in resolution of this problem. Potential biomechanical causes for this problem will be presented.