Matharu GS Nandra RS Berryman F Judge A Pynsent PB Dunlop DJ

Aims

To determine ten-year failure rates following 36 mm metal-on-metal (MoM) Pinnacle total hip arthroplasty (THA), and identify predictors of failure.

Patients and Methods

We retrospectively assessed a single-centre cohort of 569 primary 36 mm MoM Pinnacle THAs (all Corail stems) followed up since 2012 according to Medicines and Healthcare Products Regulation Agency recommendations. All-cause failure rates (all-cause revision, and non-revised cross-sectional imaging failures) were calculated, with predictors for failure identified using multivariable Cox regression.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1455 - 1462
1 Nov 2016
Matharu GS Berryman F Brash L Pynsent PB Dunlop DJ Treacy RBC

Aims

We investigated whether blood metal ion levels could effectively identify patients with bilateral Birmingham Hip Resurfacing (BHR) implants who have adverse reactions to metal debris (ARMD).

Patients and Methods

Metal ion levels in whole blood were measured in 185 patients with bilateral BHRs. Patients were divided into those with ARMD who either had undergone a revision for ARMD or had ARMD on imaging (n = 30), and those without ARMD (n = 155). Receiver operating characteristic analysis was used to determine the optimal thresholds of blood metal ion levels for identifying patients with ARMD.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 69 - 69
1 Jan 2004
Prasad V Mughal E Worthington T Dunlop DJ Treacy RBC Lambert PA Elliott TSJ
Full Access

Introduction: We have investigated the accuracy of a serological marker to distinguish between septic and aseptic loosening of Total Hip Replacements (THR). We present the preliminary results of our on-going prospective study.

Methods: After obtaining Ethical Committee approval, 46 patients were collected in 3 groups; “control” primary THR, revision THR for aseptic loosening, and revision THR for infection. Serum IgG responses to an exocellular bacterial antigen (Lipid S) were determined by enzyme-linked immunosorbent assay (ELISA).

Results: Our results show that the test can accurately differentiate between the patients with infected joint replacements and the control group. The test, to date, has a specificity of 93% and a sensitivity of 100%.

Clinical Relevance: This simple and cheap test can reliably assist in the accurate evaluation of a painful hip arthroplasty, and planning for revision surgery. It will also be useful in the management of patients in whom the microbiology results are either negative or based on a single isolate of an organism, which may be either a contaminant or a possible pathogen. This, inturn, would have implications on financial costs and the optimum use of available resources.