Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 353 - 353
1 Jul 2014
Hamilton M Diep P Roche C Flurin P Wright T Zuckerman J Routman H
Full Access

Summary Statement

Reverse shoulder design philosophy can impact external rotation moment arms. Lateralizing the humerus can increase the external rotator moment arms relative to normal anatomy.

Introduction

The design of reverse shoulders continues to evolve. These devices are unique in that they are not meant to reproduce the healthy anatomy. The reversal of the fulcurm in these devices impacts every muscle that surrounds the joint. This study is focused on analyzing the moment arms for the rotator cuff muscles involved in internal and external rotation for a number of reverse shoulder design philosophies.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 507 - 507
1 Dec 2013
Roche C Diep P Hamilton M Flurin PH Zuckerman J Routman H
Full Access

Introduction

Reverse shoulder arthroplasty (rTSA) increases the deltoid abductor moment arm length to facilitate the restoration of arm elevation; however, rTSA is less effective at restoring external rotation. This analysis compares the muscle moment arms associated with two designs of rTSA humeral trays during two motions: abduction and internal/external rotation to evaluate the null hypothesis that offsetting the humerus in the posterior/superior direction will not impact muscle moment arms.

Methods

A 3-D computer model simulated abduction and internal/external rotation for the normal shoulder, the non-offset reverse shoulder, and the posterior/superior offset reverse shoulder. Four muscles were modeled as 3 lines from origin to insertion. Both offset and non-offset reverse shoulders were implanted at the same location along the inferior glenoid rim of the scapula in 20° of humeral retroversion. Abductor moment arms were calculated for each muscle from 0° to 140° humeral abduction in the scapular plan using a 1.8: 1 scapular rhythm. Rotation moment arms were calculated for each muscle from 30° internal to 60° external rotation with the arm in 30° abduction.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 506 - 506
1 Dec 2013
Roche C Diep P Hamilton M Flurin PH Zuckerman J Routman H
Full Access

Introduction

The inferior/medial shift in the center of rotation (CoR) associated with reverse shoulder arthroplasty (rTSA) shortens the anterior and posterior shoulder muscles; shortening of these muscles is one explanation for why rTSA often fails to restore active internal/external rotation. This study quantifies changes in muscle length from offsetting the humerus in the posterior/superior directions using an offset humeral tray/liner with rTSA during two motions: abduction and internal/external rotation. The offset and non-offset humeral tray/liner designs are compared to evaluate the null hypothesis that offsetting the humerus in the posterior/superior direction will not impact muscle length with rTSA.

Methods

A 3-D computer model was developed to simulate abduction and internal/external rotation for the normal shoulder, the non-offset reverse shoulder, and the posterior/superior offset reverse shoulder. Seven muscles were modeled as 3 lines from origin to insertion. Both offset and non-offset reverse shoulders were implanted at the same location along the inferior glenoid rim of the scapula in 20° of humeral retroversion. Muscle lengths were measured as the average of the 3 lines simulating each muscle and are presented as an average length over each arc of motion (0 to 65° abduction with a fixed scapula and 0 to 40° of internal/external rotation with the humerus in 0° abduction) relative to the normal shoulder.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 164 - 164
1 Dec 2013
Roche C Diep P Grey S Flurin PH Zuckerman J Wright T
Full Access

Introduction

Posterior glenoid wear is common in glenohumeral osteoarthritis. Tightening of the subscapularis causes posterior humeral head subluxation and a posterior load concentration on the glenoid. The reduced contact area causes glenoid wear and potentially posterior instability. To correct posterior wear and restore glenoid version, surgeons may eccentrically ream the anterior glenoid to re-center the humeral head. However, eccentric reaming undermines prosthesis support by removing unworn anterior glenoid bone, compromises cement fixation by increasing the likelihood of peg perforation, and medializes the joint line which has implications on joint stability. To conserve bone and preserve the joint line when correcting glenoid version, manufacturers have developed posterior augment glenoids. This study quantifies the change in rotator cuff muscle length (relative to a nonworn/normal shoulder) resulting from three sizes of posterior glenoid defects using 2 different glenoids/reaming methods: 1) eccentric reaming using a standard (nonaugmented) glenoid and 2) off-axis reaming using an 8, 12, and 16° posterior augment glenoid.

Methods

A 3-D computer model was developed in Unigraphics (Siemens, Inc) to simulate internal/external rotation and quantify rotator cuff muscle length when correcting glenoid version in three sizes of posterior glenoid defects using posterior augmented and non-augmented glenoid implants. Each glenoid was implanted in a 3-D digitized scapula and humerus (Pacific Research, Inc); 3 sizes (small, medium, and large) of posterior glenoid defects were created in the scapula by posteriorly shifting the humeral head and medially translating the humeral head into the scapula in 1.5 mm increments. Five muscles were simulated as three lines from origin to insertion except for the subscapularis which was wrapped. After simulated implantation in each size glenoid defect, the humerus was internally/externally rotated from 0 to 40° with the humerus at the side. Muscle lengths were measured as the average length of the three lines simulating each muscle at each degree of rotation and compared to that at the corresponding arm position for the normal shoulder without defect to quantify the percentage change in muscle length for each configuration.