Advertisement for orthosearch.org.uk
Results 1 - 14 of 14
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 64 - 64
1 Mar 2017
Oh B Cho W Cho H Lee G
Full Access

Purpose

Failure resulting from a recurrent infection in total knee arthroplasty (TKA) is a challenging problem. Knee arthrodesis is one treatment option, however fusion is not always successful, as there is huge bone defect. The authors reports a new arthrodesis technique that uses a bundle of flexible intramedullary rods and an antibiotic-loaded cement spacer.

Methods

There were 13 cases of arthrodesis due to recurrent periprosthetic joint infection, which were performed by the first author (WS Cho) at Asan Medical Center in Seoul from 2005 to 2014. All previous prosthetic components were removed and cement was thoroughly excised using a small osteotome. Two stage operation was done in most of cases. After thorough debridement, antibiotics loaded cement was inserted in first stage, flexible intramedullary rods were inserted retrogradely in the femoral side with the knee in flexion under fluoroscopy guidance. After filling the femoral intramedullary canal, the rods were then driven back securely into the tibial medullary canal. We aimed for as much rod length as possible to maximize stability. After 6 weeks of first stage operation, the rods of the femoral and tibial sides were arranged such that they overlapped and interdigitated to maximize mechanical strength, maintain the limb length and keep the rotational alignment. The interdigitating rod ends were tightly fixed using two (or three) cerclage wires. Antibiotic-loaded cement was filled into the knee joint space so that the cement is fit to the irregular contour of the femur and tibia, which was resulted from the severe bone loss. Postoperatively, patients were allowed to weight bear as tolerated.


Purpose

To compare the clinical and radiological results between internal fixation using the proximal femoral nail system and bipolar hemiarthroplasty in reverse oblique intertrochanteric hip fracture in elderly patients.

Materials and Methods

From January 2005 to July 2012, we reviewed 53 patients who had been treated surgically for reverse oblique intertrochanteric fracture and been followed up on for a minimum of 2 years. The patients, all over 70 years old, were divided into two groups for retrospective evaluation: one group was treated with open reduction and internal fixation using the proximal femoral nail system (31 cases), and the other group was treated with bipolar hemiarthroplasty (22 cases).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 69 - 69
1 Feb 2017
Kim J Cho H
Full Access

Purpose

We evaluated the clinical and radiographic outcomes of cementless bipolar hemiarthroplasty using rectangular cross-section stem for femoral neck fracture in elderly patients more than 80 years of age with osteoporosis.

Material and Methods

76(cemented 46, cementless 30) bipolar hemiarthroplasties for femur neck fracture were performed in elderly patients more than 80 years old. The mean follow-up period was 4.3 years (2 to 7 years). The Harris hip score at last follow-up and pre-postoperative daily living activity scale according to Kitamura methods were analyzed clinically. The radiological results were assessed using stability of femoral stem and other complications were evaluated. Results: At last follow-up, there were no significant differences of Harris hip score and daily living activity between two groups. Stem loosening and instability were not observed in cementless arthroplasty. There were 18 cases of osseous fixation in radiologic study. There were 1 case of dislocation and 1 case of superficial infection in cemented arthroplasty and 1 case of deep infection in cementless arthroplasty.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 105 - 105
1 May 2016
Kim J Park B Cho H
Full Access

Purpose

To observe the follow-up results of standard cemented bipolar hemiarthroplasty with double loop and tension band wiring technique for treatment of unstable intertrochanteric hip fractures in elderly patients with osteoporosis.

Materials and Methods

From May 2000 to May 2006, 86 cemented bipolar hemiarthroplasties were performed in elderly patients who had unstable intertrochanteric fractures. The mean age at the time of surgery was 82 years old. The average follow-up period were 5.3 years. We evaluated post-operative results after operation by clinical and radiographic methods.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 79 - 79
1 May 2016
Cho H Park B Kim J
Full Access

Purpose

To perform comparative analysis between the results of internal fixation using proximal femoral nail system and bipolar hemiarthroplasty in pantrochanteric hip fracture in elderly patients.

Materials and Methods

From January 2006 to February 2012, we reviewed 43 patients, who were treated surgically for pantrochanterichip fractures, with a minimum of 2 years follow up. The patient's age was older than 70 year old. The patients were divided into three groups and evaluated, retrospectively. The fracture reduction were regarded as satisfactory in S-OR-IF group(17 cases) and unsatisfactory in US-OR-IF group(9 cases) and the other group was treated with bipolar hemiarthroplasty (BHA group, 17 cases.)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 221 - 221
1 Mar 2013
Cho H Kim J
Full Access

Purpose

To evaluate outcome after cementless bipolar hemiarthroplasties using a standard(tapered, rectangular) stem for the treatment of above type A2 fractures in elderly patients.

Material and methods

We reviewed the records of 37 patients who underwent bipolar hemiarthroplasty between February 2006 and Feburuary 2010 in our hospital who were followed for more than two years after surgery. The mean patient age was 73.5 years old (range 64∼88 years old). 16 patients were men, and 21 patients were women. We evaluated the results by analyzing operation time, amount of bleeding, recovery of walking ability, complications and radiologic findings.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 220 - 220
1 Mar 2013
Cho H Kim J
Full Access

Purpose

To analyze the effectiveness of a vancomycin impregnated calcium sulfate cement bead insertion after debridement (of) an acute-immediate stage infected hip arthroplasty.

Materials and Methods

Between 2002 and 2008, 13 patients with documented acute-immediate stage infection of hip arthroplasty were reviewed and followed for at least two years postoperatively(average 4.3 years). The preoperative and postoperative clinical and radiologic findings and blood laboratory work were checked. All cases were performed through retention of the implant and massive debridement and saline irrigation. After that a vancomycin impregnated calcium sulfate cement beads was inserted.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 35 - 35
1 Mar 2013
Cho H Kim J
Full Access

Recent reports about the excellent clinical results of unicondylar knee arthroplasty (UKA; also known as unicompartmental knee arthroplasty), by the minimally invasive approach, have encouraged the adoption of the surgical technique. However, friction between metallic prosthetic components resulting from polyethylene wear may result in the development of metallosis and the use of metal implants has become a huge issue in the worlds recently. Here, we report a case in which a patient underwent UKA and developed metallosis in soft tissues and bone adjacent to an implanted artificial joint three years postoperatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 36 - 36
1 Oct 2012
Park I Yoon H Cheon S Seo S Cho H
Full Access

Recently, several preliminary reports have been issued on the application of computer assistance to bone tumour surgery. Surgical navigation systems can apply three-dimensional images such as CT and MR images to intraoperative visualization. Although CT is better at describing cortical bone status, MRI is considered the best method for defining the extent of marrow involvement for bone tumours and for planning surgical resection in bone tumour surgery. There have been a few reports on the application of MR imaging to navigation-assisted bone tumour surgery through CT–MR image fusion. However, the CT–MRI fusion technique requires additional costs and exposure of the patient to radiation from the preoperative CT, as well as additional time for image fusion. Above all, the image fusion process is a kind of registration (image to image registration) that inevitably leads to registration error. Herein we describe a new method for the direct application of MR images to navigation-assisted bone tumour surgery as an alternative to CT–MRI fusion.

Six patients with an orthopaedic malignancy were employed for this method during navigation-assisted tumour resection. Resorbable pin placement and rapid 3-dimensional spoiled gradient echo sequences made the direct application of MR images to computer-assisted bone tumour surgery without CT–MR image fusion possible. A paired-point registration technique was employed for patient-image registration in all patients. It took 20 min on average to set up the navigation (range 15 to 25 minutes). The mean registration error was 0.98 mm (range 0.4 to 1.7 mm). On histologic examination, distances from tumours to resection margins were in accord with preoperative plans. Mean duration of follow-up was 25.8 months (range 18 to 32 months). No patient had a local recurrence or distant metastasis at the last follow-up.

Direct patient-to-MRI registration is a very useful method for bone tumour surgery, permitting the application of MR images to intraoperative visualization without any additional costs or exposure of the patient to radiation from the preoperative CT scan.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 423 - 423
1 Nov 2011
Bae DK Yoon KH Song SJ Shin M Noh J Park M Cho H Choi I
Full Access

In conventional high tibial osteotomy it is difficult to obtain the ideal correction angle consistently and there is high variability of postoperative alignment. We assessed the reliability, accuracy and variability of closed wedge high tibial osteotomy using computer-assisted surgery compared to the conventional technique. Fifty closed wedge HTO procedures were performed and analysed between July 2005 and July 2006, using the CT-free navigation system(Vector Vision® version 1.1, Brain-LAB, Heimstetten, Germany) for medial compartment osteoarthritis of the knee and fifty knee operations using conventional closed-wedge HTO, performed between 1994 and 2006, were retrospectively reviewed as a control group. The mean age was 59.4 years for the navigation group and 60.7 years for the conventional group. In the navigation group, the mean mechanical axis (MA) before osteotomy was varus 8.2°, and the mean MA after the fixation was valgus 3.6°. On the radiographs, the mean preoperative MA was varus 7.3°, and the mean postoperative MA was valgus 2.1°. In the conventional group, the mean MA was varus 10.6° preoperatively and valgus 0.1° postoperatively via the radiograph. The mean preoperative posterior slope angle (PSA) was 11.0°, which decreased to 9.0° in the navigation group. The mean preoperative PSA was 10.4°, which decreased to 6.4° in the conventional group(p = 0.000). There was a positive correlation between measured data taken under navigation and by radiographs(r > 0.3, P < 0.05). The mean correction angle was significantly more accurate in the navigation group(p < 0.002). The variability of the correction was significantly lower in the navigation group (2.3° versus 3.7°, p = 0.012), and the distribution of MA was also narrower in the navigated group.

We concluded that navigation provides reliable real-time intraoperative information and may increase accuracy, and improve the precision of closed-wedge HTO.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 91 - 91
1 Mar 2010
BAE D Song S Cho H
Full Access

We analysed the clinical and radiographic results after total knee arthroplasty in the valgus knee. Thirty six knees in 27 patients with a valgus alignment of more than 10 degrees of femorotibial angle underwent TKA. The average followup period was 7 years(range 1 to 14 years). Eighteen knees were implanted with a cruciate retaining prosthesis, 17 knees with a posterior stabilized prosthesis, and one knee with a constrained condylar prosthesis. In knees with a preoperative 15 degrees or greater femorotibial angle, the posterior stabilized prosthesis were necessary in 85%.

Medial parapatellar approach was used in 27 knees with a preoperative valgus 20 degrees or lesser femorotibial angle. With 20 to 29 degrees valgus, medial parapatellar approach was used in 5 knees and lateral parapatellar approach in 2 knees. With 30 degrees or greater valgus, lateral parapatellar approach was used in 2 knees.

The mean postoperative Hospital for Special Surgery knee scores were 89.5 points. Postoperative range of motion averaged 114.4 degrees. Postoperative alignment averaged 6.5 degree valgus. Radiolucent line or loosening was not seen in any knee. There were two deep infections in patients whose preoperative femorotibial angle was greater than valgus 20 degrees using lateral parapatellar approach.

Clinical and functional results after TKA in the valgus knee were similar to those in varus knee. But, prevention of deep infection in patients with marked valgus angle was important, especially using lateral parapatellar approach. A more constrained prosthesis was frequently used in more significant valgus deformity. In patients with severe valgus deformity needing lateral capsular release frequently, lateral parapatellar capsular approach was more reasonable than medial parapatellar approach to avoid medial and lateral capsular release simultaneously.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 144 - 144
1 Mar 2010
Park M Cho H Lee SR Kim TS
Full Access

Twenty-Six total hip arthroplasties were performed in Crowe grade 3 or 4 hip dysplasia using subtrochanteric shortening osteotomy with 2-kinds of femoral stem(Primary monoblock and modular femoral stem). The average age was 46.2 years, and the average follow-up was 4.1 years. Acetabular reconstruction with structural autograft was used in 13 hips. Radiologically, hip centers were nearly normalized by vertical height of 10.6mm elevation and horizontal lengths of 1.7mm compared with uninvolved sites. Three of four osteotomy nonunions were managed with bone graft and other one wating for surgery. One acetabular revision was performed for migration. One postoperative dislocation was managed successfully with closed reduction and abduction brace. One patient (> 7cm) showed postoperative neurologic complications was noted. Harris hip score was improved from 35.6 to 81.7. A cementless modular distal fluted femoral stem is a useful device in these patients.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 112 - 112
1 Mar 2010
Park S Cho H Han SB Park J Jeong W Chung N Won-Noh
Full Access

Background: There area some controversies about the need for revision of well fixed femoral stem during the revision total hip arthroplasty. The purpose of this study is to evaluate the state of unretrieved femoral stem, in revision total hip arthroplasty where only acetabular component was revised.

Methods: From January 1998 to December 2004, thirty-one patients underwent revision total hip arthroplasty whose well fixed femoral stem was retained and acetabular components revised. Twenty-six patients(29hips) with a minimum follow-up of three years were included in this study. Out of those twenty-six patients, sixteen patients(18hips) were male and ten patients(11hips) were female with an average age of 54.3 years for the study group. The average time from the primary operation until the revision surgery was 9.2 years and the average follow-up period after the revision was 5 years. The femoral head component was exchanged in all cases and same size femoral head component was used in eleven hips. The clinical results wee analyzed using Harris Hip Score, and the radiographs were reviewed for stability of acetabular components, femoral stem, and degree of osteolysis and radiolucent lines.

Results: The average Harris Hip score improved from 56.3 points preoperatively to 89.8 points postoperatively. Femoral stems were found to be stable in all hips. Sixteen hips(55.2%) showed evidence of osteolysis and seven hips(24.1%) showed non-progressive radiolucent lines. The osteolysis was detected at Gruen Zone I and VII in most of the affected hips except for two hips which showed distal osteolysis. The average life of femoral stem from primary operation until the final follow up varied from 10.8 years to 18.2 years, with the average being 14.2 years.

Conclusions: We recommended that well fixed, stable femoral components can be retained at the time of revision total hip arthroplasty.

Level of evidence: Therapeutic Level IV


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 125 - 125
1 Mar 2010
Kim T Kang Y Chang C Chung B Cho H Seong S
Full Access

Application of computer assisted navigation (CAN) has been documented to improve the accuracy of limb alignment and implant positioning. However, a recent study reported that a great deal of disparities occurred between the radiographic and navigational measurements calling the basic argument for application of CAN to TKA into question. In the authors’ practice using CAN for TKA, we have observed consistent disparities between the preoperative radiographic assessments and intraoperative navigational assessments of limb alignment in the coronal plane. A large disparity between radiographic and navigational assessments of limb alignment would be presenting a challenging question whether or not the surgeon can rely on the information provided by the CAN system. We developed a novel method to measure the coronal limb alignment and have found that the radiographic measurements with the novel method remarkably reduce the disparities between the radiographic and navigational assessments of the coronal limb alignment. This study was conducted to document the existence of the disparities between the radiographic and navigational assessments of the limb alignment and the value of our novel method to perform preoperative radiographic measurements of limb alignment.

In 107 TKAs performed using a CAN system (Ortho-pilot: B. Braun-Aesculap, Tuttlingen, Germany), radiographic assessments of coronal limb alignment were assessed using preoperative and postoperative whole limb radiographs taken with weight bearing with two different methods: a standard method, angle between the femoral mechanical axis (the line connecting hip center and the top pint of the femoral intercondylar notch) and a tibial mechanical axis (the line connecting the mid-point between the medial and lateral tibial eminences and the mid-point of the talus dome) and a novel method, the angle between the weight loading line (the line connecting the hip center and the mid-point of the talus dome) and the tibial mechanical axis. A negative value was given to a varus alignment and a positive value to the valgus alignment. During surgery, the coronal limb alignment was measured by the navigation system two different time-points: after registration and after implantation of prostheses. The disparity between the radiographic and navigational assessments was calculated with subtracting the radiographic assessments by the navigational assessments.

The disparity between the radiographic and navigational assessments was significantly smaller with the novel method than with the standard method. The mean difference between the radiographic and navigational assessments of preoperative limb alignment was −6.5o (range: −19 ~ 1) with the standard method and −0.9o (range: −8o to 4o) with the novel method. The mean difference between the radiographic and navigational assessments of the postoperative limb alignment was −1.96 (range: −11 ~ 3) with the standard method and −1.3 (range: −6 ~3).

This study documents that a wide range of disparities occurs between the radiographic and navigational assessments of limb alignment and the amount of disparity occurs in preoperative assessments. Our findings indicate that our novel method to perform the radiographic assessments of limb alignment can be a useful tool to interpret the information intraoperatively given by the navigation system.