Ankle fusion (AF), a durable intervention for ankle arthritis, has been the management of choice but restricts mobility. Recently, total ankle replacement (TAR) has been offered to patients looking to maintain mobility. The aim was to compare the biomechanics of AF and TAR while walking on inverted and everted slopes which create a greater demand for complex foot mobility than level walking. A ten-camera motion detection setup captured trials as patients walked in both directions over a 5⁰ lateral slope with embedded force plates. Moments (Nm/Kg) across the knee and ankle were exported from Visual 3D in the sagittal and frontal plane, and data were reported as means with 95% confidence intervals. 15 patients were recruited (6 TAR, 9 AF). The median age, follow-up and BMI was 67 years, 4 years and 35.8 kg/m² in AF, and 73 years, 7 years and 28.1 kg/m² in TAR, respectively. During inverted slope walking (4 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.38 (0.37–0.39) vs AF 0.37 (0.27–0.52) and (ii) the ankle: TAR 0.20 (0.13–0.27) vs AF 0.25 (0.18–0.32), and extension moments across (i) the knee: TAR 0.68 (0.38–0.97) vs AF 0.85 (0.69–1.01) and (ii) the ankle: TAR 1.46 (1.30–1.62) vs AF 1.30 (1.08–1.52). During everted walking (5 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.41 (0.30–0.52) vs AF 0.46 (0.27–0.66) and (ii) the ankle: TAR 0.24 (0.11–0.38) vs AF 0.26 (0.18–0.33), and extension moments across (i) the knee: TAR 0.76 (0.54–0.99) vs AF 0.93 (0.72–1.14) and (ii) the ankle: TAR 1.39 (1.19–1.59) vs AF 1.26 (1.04–1.48). There were no differences in abduction moments during inverted or everted slope walking. However, patients with AF had increased extension moments across the knee, particularly on inverted slopes, suggesting that AF creates a greater demand for knee compensation than TAR.
To be able to assess the biomechanical and functional effects of ankle injury and disease it is necessary to characterise healthy ankle kinematics. Due to the anatomical complexity of the ankle, it is difficult to accurately measure the Tibiotalar and Subtalar joint angles using traditional marker-based motion capture techniques. Biplane Video X-ray (BVX) is an imaging technique that allows direct measurement of individual bones using high-speed, dynamic X-rays. The objective is to develop an in-vivo protocol for the hindfoot looking at the tibiotalar and subtalar joint during different activities of living. A bespoke raised walkway was manufactured to position the foot and ankle inside the field of view of the BVX system. Three healthy volunteers performed three gait and step-down trials while capturing Biplane Video X-Ray (125Hz, 1.25ms, 80kVp and 160 mA) and underwent MR imaging (Magnetom 3T Prisma, Siemens) which were manually segmented into 3D bone models (Simpleware Scan IP, Synopsis). Bone position and orientation for the Talus, Calcaneus and Tibia were calculated by manual matching of 3D Bone models to X-Rays (DSX Suite, C-Motion, Inc.). Kinematics were calculated using MATLAB (MathWorks, Inc. USA). Pilot results showed that for the subtalar joint there was greater range of motion (ROM) for Inversion and Dorsiflexion angles during stance phase of gait and reduced ROM for Internal Rotation compared with step down. For the tibiotalar joint, Gait had greater inversion and internal rotation ROM and reduced dorsiflexion ROM when compared with step down. The developed protocol successfully calculated the in-vivo kinematics of the tibiotalar and subtalar joints for different dynamic activities of daily living. These pilot results show the different kinematic profiles between two different activities of daily living. Future work will investigate translation kinematics of the two joints to fully characterise healthy kinematics.
The importance of cup position on the performance of total hip replacements (THR) has been demonstrated in Pelvic movement data for walking for 39 unilateral THR patients was acquired (Leeds Biomedical Research Centre). Patient's elected walking speed was used to group patients into high- and low-functioning (mean speed, 1.36(SD 0.09)ms−1 and 0.85(SD 0.08)ms−1 respectively). A computational algorithm (Python3.7) was developed to calculate cup version during gait cycle. Inputs were pelvic angles and initial cup orientation (assumed to be 45° inclination and 7° version, anterior pelvic plane was parallel to radiological frontal plane). Outputs were cup version angles during a gait cycle (101 measurements/cycle). Minimum, maximum and average cup version during gait cycle were measured for each patient. Two-sample t-test (p=0.05) was used to compare groups.Abstract
Objectives
Methods
Implant loosening remains a common cause of total ankle replacement (TAR) revision, and has been associated with wear-mediated osteolysis. Limited pre-clinical studies for TARs have been reported and the variety of experiment settings make it difficult to compare wear rates. Factors such as simulator control mechanism; whether pneumatic or electromechanical, may influence the integrity of the simulator outputs with respect to input profiles. This study compares the wear of a TAR, tested in electromechanical and pneumatic experimental simulators under identical input conditions. Twelve medium BOX® (MatOrtho Ltd) TARs (n=6 for each simulator) were tested in an electromechanical and pneumatic knee simulator (Simulation Solutions, UK) for 3 million cycles (Mc). Standard ‘Leeds’ displacement-controlled inputs were used. Kinematic performance was investigated by comparing the output profiles against the maximum demanded input values. The lubricant used was 25% new-born calf serum and wear was determined gravimetrically.Abstract
Objectives
Methods
Skeletal kinematics are traditionally measured by motion analysis methods such as optical motion capture (OMC). While easy to carry out and clinically relevant for certain applications, it is not suitable for analysing the ankle joint due to its anatomical complexity. A greater understanding of the function of healthy ankle joints could lead to an improvement in the success of ankle-replacement surgeries. Biplane video X-ray (BVX) is a technique that allows direct measurement of individual bones using highspeed, dynamic X-Rays. To develop a protocol to quantify in-vivo foot and ankle kinematics using a bespoke High-speed Dynamic Biplane X-ray system combined with OMC. Two healthy volunteers performed five level walks and step-down trials while simultaneous capturing BVX and synchronised OMC. participants undertook MR imaging (Magnetom 3T Prisma, Siemens) which was manually segmented into 3D bone models (Simpleware Scan IP, Synopsis). Bone position and orientation for the Talus, Tibia and Calcaneus were calculated by manual matching of 3D Bone models to X-Rays (DSX Suite, C-Motion, Inc.). OMC markers were tracked (QTM, Qualisys) and processed using Visual 3D (C-motion, Inc.).Abstract
Objective
Methods
Total ankle arthroplasty (TAA) is an alternative to ankle arthrodesis, replacing the degenerated joint with a mechanical motion-preserving alternative. Implant loosening remains a primary cause of TAA revision, and has been associated with wear-mediated osteolysis. Differing implant designs have a major influence on the wear performance of joint replacements. Providing a range of implant sizes allows surgeons a greater intra-operative choice for varying patient anatomy and potential to minimise wear. Minimal pre-clinical testing exists in the literature that investigates the effect of implant size on the wear behaviour. The aim of this study therefore was to investigate the effect of two different implant sizes on the wear performance of a TAA. Six ‘medium’ and six ‘extra small’ BOX® (MatOrtho Ltd, UK) TAA implants, of the same conceptual design and polyethylene insert thickness, were tested in a modified 6 station pneumatic knee simulator. 5 million cycles (Mc) of wear simulation were completed for each implant size, under kinematics aiming to replicate an ankle gait cycle (Figure 1) [1]. The simulator used had six degrees of freedom, of which four were controlled. The maximum axial load was 3150N, equivalent to 4.5 times body weight of a 70kg individual. The flexion profile ranged from −15° plantarflexion to 15° dorsiflexion. Rotation about the tibial component ranged from −2.3° of internal rotation to 8° external rotation, and anterior/posterior (AP) displacement ranged from 3.1 mm anterior to −0.9 mm posterior displacement. The lubricant used was 25% bovine serum supplemented with 0.04% sodium azide to prevent bacterial degradation. The wear of the TAA polyethylene inserts were determined gravimetrically after each Mc, with unloaded soak controls used to compensate for the uptake of moisture by the polyethylene.Background
Materials & Methods
Total hip replacement (THR) patients are often considered a homogenous group whereas in reality, patients are heterogeneous. Variation in revision rates between patient groups suggest that implants are exposed to different environmental conditions in different patients [1]. Previous reports suggest that for every unit increase of BMI, there is a 2% increased risk of revision of a THR [2]. The aim of this study was to better understand the effect of patient-specific characteristics such as BMI on hip motions and to explore the possible impact on wear. 137 THR patients, at least 12 months post-surgery, underwent 3D kinematic (Vicon, Oxford, UK) and kinetic (AMTI, USA) analysis whilst walking at self-selected walking speed. 3D kinematic data were then mapped onto a modelled femoral cup at 20 pre-determined points to create pathways for femoral head contact, which were then quantified by deriving the aspect ratio (AR). Patients were stratified into three groups determined by BMI scores; healthy weight (BMI ≤25 kg/m2) (n=34); overweight (BMI >25kg/m2 to ≤ 30 kg/m2) (n=66) and obese patients (BMI > 30 kg/m2) (n=37). Comparisons were made using 95% confidence intervals (CI) and one way ANOVAs.Introduction
Methods
One of the known mechanisms which could contribute to the failure of total hip replacements (THR) is edge contact. Failures associated with edge contact include rim damage and lysis due to altered loading and torques. Recent study on four THR patients showed that the inclusion of pelvic motions in a contact model increased the risk of edge contact in some patients. The aim of current study was to determine whether pelvic motions have the same effect on contact location for a larger patient cohort and determine the contribution of each of the pelvic rotations to this effect. Gait data was acquired from five male and five female unilateral THR patients using a ten camera Vicon system (Oxford Metrics, UK) interfaced with twin force plates (AMTI) and using a CAST marker set. All patients had good surgical outcomes, confirmed by patient-reported outcomes and were considered well-functioning, based on elective walking speed. Joint contact forces and pelvic motions were obtained from the AnyBody modelling system (AnyBody Technologies, DK). Only gait cycle regions with available force plate data were considered. A finite element model of a 32mm head on a featureless hemispherical polyethylene cup, 0.5mm radial clearance, was used to obtain the contact area from the contact force. A bespoke computational tool was used to analyse patients' gait profiles with and without pelvic motions. The risk of edge contact was measured as a “centre proximity angle” between the cup pole and centre of the contact area, and “edge proximity angle” between the cup pole and the furthest contact area point away from the pole. Pelvic tilt, drop and internal-external rotation were considered one at a time and in combinations.Introduction
Methods
Whilst lateral ankle sprain is often considered a benign injury it represents between 3–5% of all A&E visits in the UK. The mechanical characteristics of ankle ligaments under sprain-like conditions are scarcely reported. The lateral collateral ankle ligaments were dissected from n=6 human cadaveric specimens to produce individual bone-ligament-bone specimens. An Instron Electropuls E10000 was used to uni-axially load the ankle ligaments in tension. The ligaments were first preconditioned between 2 N and a load value corresponding to 3.5% strain for 15 cycles and then strained to failure at a rate of 100%/s. The mean ultimate failure loads and their standard deviations for the anterior talofibular (ATFL), calcaneofibular (CFL) and posterior talofibular (PTFL) ligaments are 351.4±105.6 N, 367.8±76.1 N and 263.6±156.6 N, respectively. Whilst the standard deviation values are high they align with those previously reported for ankle ligament characterisation. The large standard deviations are partly due to the inherent variability of human cadaveric tissue but could also be due to varying previous activity levels of participants or a prior unreported ankle sprain. Although the sample size is relatively small the results were stratified to identify any potential correlations of age, BMI and weight with ultimate load. A strong Pearson correlation (r=0.919) was found between BMI and ultimate load of the CFL but a larger sample size is required to confirm a link. The ligament failure modes were observed and categorised as avulsion or intra-ligamentous failure. The ATFL avulsed from the fibula in five instances and intra-ligamentous failure occurred once. The CFL avulsed from the fibula twice and failed four times through intra-ligamentous failure. Finally, the PTFL avulsed from the fibula once, avulsed from the talus once and failed through intra-ligamentous failure in four instances. The results identify the forces required to severely sprain the lateral collateral ankle ligaments and their failure modes.
Total ankle replacement (TAR) is a substitute to ankle fusion, replacing the degenerated joint with a mechanical motion-conserving alternative. Compared with hip and knee replacements, TARs remain to be implanted in much smaller numbers, due to the surgical complexity and low mid-to-long term survival rates. TAR manufacturers have recently explored the use of varying implant sizes to improve TAR performance. This would allow surgeons a wider scope for implanting devices for varying patient demographics. Minimal pre-clinical testing has been demonstrated to date, while existing wear simulation standards lack definition. Clinical failure of TARs and limited research into wear testing defined a need for further investigation into the wear performance of TARs to understand the effects of the kinematics on varying implant sizes. Six medium and six extra small BOX® (MatOrtho) TARs will be tested in a modified knee simulator for 5 million cycles (Mc). The combinations of simulator inputs that mimic natural gait conditions were extracted from ankle kinematic profiles defined in previous literature. The peak axial load will be 3.15 kN, which is equivalent to 4.5 times body weight of a 70kg individual. The flexion profile ranges from 15° plantarflexion to 15° dorsiflexion. Rotation about the tibial component will range from −2.3° of internal rotation to 8° external rotation, while the anterior/posterior displacement will be 7mm anterior to −2mm posterior throughout the gait cycle. The components will be rotated through the simulation stations every Mc to account for inter-station variability. Gravimetric measurements of polyethylene wear will be taken at every Mc stage. A contact profilometer will also be used to measure average surface roughness of each articulating surface pre-and-post simulation. The development of such methods will be crucial in the ongoing improvement of TARs, and in enhancing clinical functionality, through understanding the envelope of TAR performance.
In the UK, the posterior approach (PA) and direct lateral approach (DLA) are the most common total hip arthroplasty (THA) procedures. Few studies however, have compared the subsequent functional outcomes. This exploratory study aimed to examine the effect of PA and DLA approaches on post-operative hip kinematics, strength and hip muscle cross-sectional area (CSA), compared to healthy controls. Participants comprised of 15 cases in the DLA group, > 12 month post-operatively, (ten male, age 68.9+/-5.5 years, BMI 26.9+/-3.0), 13 cases in the PA group (six male; age 72.9+/-6.9 years, BMI 27.1+/-3.6) and 11 age/BMI-matched healthy control participants. All participants underwent 3D kinematic (Vicon, Oxford, UK) and kinetic (AMTI, USA) analysis whist performing self-selected and fast walking as well as sit-to-stand and stand-to-sit. Isometric dynamometry was performed (Biodex Medical systems, USA) for all major muscle groups around the operated hip, and a subset of five participants (three DLA v two PA) underwent “slice encoding for metal artefact correction” (SEMAC) MRI imaging to measure muscle CSA. Patient-reported outcome measures were collected. Both post-operative surgical groups exhibited altered gait, particularly in limited hip extension, compared to the control participants. The DLA group demonstrated forced hip extension matching controls only under fast walking conditions while the PA group did not achieve hip extension. Both surgical approaches achieved high PROMs scores. The PA group were weaker for all strength activities tested, whereas the DLA cases demonstrated similar hip strength to controls. SEMAC imaging revealed reduced CSA for those muscles dissected during surgery, compared to the contralateral side. This exploratory study demonstrated small but measurable differences between surgical approaches for muscle CSA, hip strength of major hip muscle groups and a number of gait variables, although both approaches produce satisfactory functional outcomes for patients after surgery.
This study shows a significant reduction in knee adduction moment in patients with medial compartment osteoarthritis, in both the symptomatic and asymptomatic knees. Long-term follow-up studies are required to confirm the effect of treating the asymptomatic side on disease progression. The knee is the commonest joint to be affected by osteoarthritis, with the medial compartment commonly affected. Knee osteoarthritis is commonly bilateral, yet symptoms may initially present unilaterally. Higher knee adduction moment has been associated with the development and progression of medial compartment knee osteoarthritis. The aim of this study was to assess the effect of lateral wedge insoles on the asymptomatic knee of patients with unilateral symptoms of medial compartment knee osteoarthritis.Summary
Background
The knee is the commonest joint to be affected by osteoarthritis, with the medial compartment commonly affected. Knee osteoarthritis is commonly bilateral, yet symptoms may initially present unilaterally. Higher knee adduction moment has been associated with the development and progression of medial compartment knee osteoarthritis. To assess the effect of lateral wedge insoles on the asymptomatic knee of patients with unilateral symptoms of medial compartment knee osteoarthritis.Background
Objectives