header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 3 - 3
1 Jul 2012
Platts C Caesar B Gowtham G Cresswell T Espag M
Full Access

Recurrent shoulder instability in those with bony defects is a difficult surgical problem to resolve. Burkhart and De Beer described an unacceptably high recurrence rate for arthroscopic Bankart repair in the presence of an inverted-pear glenoid with or without an engaging Hill-Sachs lesion, with suggestions that an open modified Latarjet procedure should be recommended in such patients. The Congruent-Arc Latarjet is a modification of the Latarjet open bony stabilisation for shoulder instability developed by Burkhart and De Beer. It involves rotation of the coracoid so the curved under-surface lies congruent with the glenoid. At the Royal Derby Hospital, UK, this procedure has been adopted by our four shoulder surgeons, two of whom undertook fellowship training with De Beer, we studied the outcomes of the patients who had undergone the modified Congruent-Arc Latarjet procedure in our department.

Fifty-two consecutive patients were identified over a five-year period at the Royal Derby Hospital or Derbyshire Royal Infirmary between 2006 and 2010 inclusive. With the approval of the clinical audit department, the data was collected using theatre records and clinical coding information to identify the patient group. A review of the case notes and local PACS system was undertaken to establish pre and post-operative examination findings, radiology findings regarding Hill-Sachs defects and glenoid bone loss, re-dislocation rates and post-operative function with return to normal activity. The endpoints of this study were aimed at finding out whether patients did return to normal function, were able to continue doing activity that would have provoked dislocation prior to surgery, and how many of the cases re-dislocated.

No surgeon consultant had a patient who re-dislocated after this procedure. The follow-up period was from 1 year to 6 years post-operatively. The complications of this procedure were found to be the dislodgement of bone anchors in 2 patients, who required further arthroscopy to remove the suture anchor from the gleno-humeral joint. One patient had prolonged functionally limiting loss of external rotation, which resolved after intensive physiotherapy at 7 months follow up. We will provide graphical representation of the pre and post operative functional scores.

We have demonstrated that the Congruent-Arc Latarjet is a reproducible procedure in the hands of surgeons other than the original authors, particularly when comparing our current 0% re-dislocation rate with the published literature, which suggests that 3.9% of patients undergoing this procedure with greater than 25% bone loss of the glenoid or an engaging Hill-Sachs will re-dislocate post-operatively, and this is better than the 6% re-dislocation rate of the standard Bristow-Latarjet procedure.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 41 - 41
1 Jan 2011
Caesar B Morgan-Jones R Warren R Wade R Roberts P Richardson J
Full Access

Thirty-five patients were followed prospectively from their referral to the Problem Fracture Service with chronic osteomyelitis of diaphyseal bone between November 1994 and June 1999.

The patients were treated using a closed double-lumen suction irrigation system following reaming and arthroscopic debridement of the intramedullary canal; this is a modified system based on the work of Charles Lautenbach. Results of these procedures were regularly followed up in clinic, and between June and July 2007 the whole cohort was reviewed via postal questionnaire, telephone and case note review.

At a mean follow up of 101 months, 26 were living with no evidence of recurrence, 4 had died of unrelated causes with no evidence of recurrent infection. Four patients had persisting problems with sinus discharge requiring intermittent antibiotic therapy and 1 patient had his limb amputated for recurrent metaplastic change.

These results gave this cohort an 86% clearance of infection, with recurrence in 12%, which is comparable to the Papineau and Belfast techniques with significantly less surgical insult to the patient.