Vol. 101-B, Issue SUPP_2 | Pages 15 - 15
1 Jan 2019
Rochelle D Herbert A Ktistakis I Redmond AC Chapman G Brockett CL
Full Access

Whilst lateral ankle sprain is often considered a benign injury it represents between 3–5% of all A&E visits in the UK. The mechanical characteristics of ankle ligaments under sprain-like conditions are scarcely reported.

The lateral collateral ankle ligaments were dissected from n=6 human cadaveric specimens to produce individual bone-ligament-bone specimens. An Instron Electropuls E10000 was used to uni-axially load the ankle ligaments in tension. The ligaments were first preconditioned between 2 N and a load value corresponding to 3.5% strain for 15 cycles and then strained to failure at a rate of 100%/s.

The mean ultimate failure loads and their standard deviations for the anterior talofibular (ATFL), calcaneofibular (CFL) and posterior talofibular (PTFL) ligaments are 351.4±105.6 N, 367.8±76.1 N and 263.6±156.6 N, respectively. Whilst the standard deviation values are high they align with those previously reported for ankle ligament characterisation. The large standard deviations are partly due to the inherent variability of human cadaveric tissue but could also be due to varying previous activity levels of participants or a prior unreported ankle sprain. Although the sample size is relatively small the results were stratified to identify any potential correlations of age, BMI and weight with ultimate load. A strong Pearson correlation (r=0.919) was found between BMI and ultimate load of the CFL but a larger sample size is required to confirm a link. The ligament failure modes were observed and categorised as avulsion or intra-ligamentous failure. The ATFL avulsed from the fibula in five instances and intra-ligamentous failure occurred once. The CFL avulsed from the fibula twice and failed four times through intra-ligamentous failure. Finally, the PTFL avulsed from the fibula once, avulsed from the talus once and failed through intra-ligamentous failure in four instances.

The results identify the forces required to severely sprain the lateral collateral ankle ligaments and their failure modes.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 44 - 44
1 Oct 2016
Stratton-Powell A Tipper JL Williams SD Redmond A Brockett CL
Full Access

Total ankle replacement (TAR) has a mean survivorship of 77% at 10 years which is poor compared to other types of joint arthroplasty. Osteolysis and aseptic loosening are commonly cited TAR failure modes, the mechanisms of which are unknown. Retrieval analyses of TAR devices may reveal mechanisms of failure similar or dissimilar to other joint replacements. This study investigated whether TAR explants exhibit similar damage modes to those recognised in other total joint replacements.

22 Ankle Evolution System TARs (Transystème, Nimes, France) were implanted and retrieved by the same surgeon. Mean implantation time was 7.8 yrs (5.3 to 12.1 range). Pain and/or loosening were the indications for revision. Macro photography, an Alicona Infinite microscope and the Hood/Wasielewski scale were used to classify damage modes on the polyethylene insert. Scanning electron microscopy with energy dispersive X-ray spectroscopy was used to determine the composition of third body debris and to image the fixation surface of the tibial components.

Mean damage score was 185.4 (± 40.0 SD). Damage modes common to total knee replacements were identified on both the superior and inferior insert surfaces, these included: burnishing, scratching, pitting and abrasion. Titanium particles, hydroxyapatite fragments and bone debris were embedded in the insert surfaces. Fixation surface delamination was identified by the ongrowth of tissue between the cobalt chromium substrate and titanium alloy coating.

Damage modes indicative of high levels of wear and deformation were evident. Pitting caused by third body debris was abundant and suggested fixation surface wear and failure.