Laky B Heuberer P Brandl G Kriegleder B Anderl W Pauzenberger L
Full Access

In the past century several shoulder reconstruction systems with different types of prostheses and fixation methods have been developed to improve shoulder arthroplasty, especially to cover a wide range of pathologies and revision situations. The aim of this prospective trial was to report clinical and radiological mid-term results of a stemless humeral head replacement with metaphyseal hollow screw fixation.

A consecutive series of 147 shoulders in 138 patients (84 female, 54 male; mean age of 67 years, range 40–84) undergoing stemless humeral head arthroplasty were considered for this single-centre trial. We prospectively followed 120 shoulders (40 hemi- and 80 total-arthroplasties) for an average of five years or until a reoperation. Patient's clinical and functional outcome was evaluated according to the Constant score and active range of motions (ROM) was measured. Patient's satisfaction with the treatment was evaluated. Additionally, operating times and complications were recorded. Radiological assessment for radiolucencies or implant migration was performed.

The mean Constant score significantly increased from 35 points preoperatively to 62 points at the last follow-up (p<0.001). All subcomponents (pain, daily activity, ROM, strength) of the Constant score were significantly (p<0.001) higher at follow-up. Active flexion improved from 90° to 150° (p<0.001), active abduction from 78° to 120° (p<0.001), and active external rotation from 20° to 40° (p<0.001) between preoperative and last clinical assessment. Furthermore, 54% of the patients were very satisfied, 34% satisfied, and 12% unsatisfied. Operating times of the new stemless prosthesis were significantly shorter compared to a stemmed prosthesis. Over the follow-up period, all humeral head components were radiological centred, changing radiolucencies were detected; however no implant loosening occurred. Revision surgery for implant loosening only occurred in the metal-backed glenoid component with hollow screw fixation; otherwise no complication due to implant loosening was detected.

The promising five-year results suggest that the concept of this stemless humeral head replacement might be an expedient alternative to existing shoulder replacements. Anatomical cutting of the humeral head and hollow screw fixation allow a familiar access to the glenoid combined with a shaft independent, less complex bone-sparing surgery along with shorter operating times and favourable revision situation.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 114 - 114
1 May 2016
Laky B Koelblinger R Brandl G Anderl W Schwameis E
Full Access

Arthrodesis of the first metatarsophalangeal joint (MTPJ) has been reported as gold standard for the treatment of advanced hallux rigidus and is a well-documented procedure. However, many patients demand a mobile MTPJ and therefore joint sparing procedures like MTPJ-arthroplasty have gained popularity. The aim of the present study was to present first mid-term results after hemiarthroplasty to treat advanced osteoarthritis of the first MTPJ.

Between April 2006 and October 2013, a total of 81 hemiprostheses (AnaToemic®, Arthrex) in 71 consecutive patients (44 females, 27 male, 10 bilateral; mean age, 58 [range, 45–82]) were implanted at the St. Vincent Hospital Vienna (Austria). The indication for surgery was persistent MTPJ pain after failed conservative treatment combined with radiologic evidence of osteoarthritis (advanced hallux rigidus grade II-IV). Patients were clinically examined using the American Orthopaedic Foot and Ankle Society (AOFAS) score before surgery and at the final follow-up visit. Patient's satisfaction with the treatment was recorded. Radiological results were evaluated using standard x-rays and revision surgeries were documented.

The mean preoperative AOFAS Scores significantly increased from 51 to 88 points after an average follow-up duration of 5 years (p<0.001). Most patients (76%) were either very satisfied or satisfied with the procedure. Radiological assessment showed some kind of radiolucencies on the base plate, whereas the stem of the prosthesis was well integrated in most of the cases; however clinical outcome was not affected by minor radiolucent lines on the base plate. In the majority of patients the implant was in situ at last follow-up. If revision surgery, due postoperative pain or implant loosening, was required; it occurred within 12 to 36 months.

According to our promising mid-term results with a MTPJ-hemiprostheses, we conclude that MTPJ-arthroplasty is an effective alternative treatment modality for anatomical reconstruction of the first MTPJ with the benefit to reduce pain and maintain mobility.