Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 54 - 54
1 Feb 2017
Brown M Plate J Holst D Bracey D Bullock M Lang J
Full Access

Background

Fifteen to twenty percent of patients presenting for total hip arthroplasty (THA) have bilateral disease. While simultaneous bilateral THA is of interest to patients and surgeons, debate persists regarding its merits. The majority of previous reports on simultaneous bilateral THA involve patients in the lateral decubitus position, which require repositioning, prepping and draping, and exposure of a fresh wound to pressure and manipulation for the contralateral THA. The purpose of this study was to compare complications, component position, and financial parameters for simultaneous versus staged bilateral THAs using the direct anterior approach (DAA).

Methods

Medical records were reviewed for patient demographics, medical history, operative time, estimated blood loss (EBL), change in hemoglobin, transfusion, tranexamic acid (TXA) use, length of stay (LOS), discharge disposition, leg length discrepancy, acetabular cup position, and perioperative complications. Cost and reimbursement data were analyzed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 91 - 91
1 Dec 2013
Plate JF Augart MA Bracey D Von Thaer S Allen J Sun D Poehling G Jinnah R
Full Access

Introduction

There has been renewed interest in the use of unicompartmental knee arthroplasty (UKA) for patients with limited degenerative disease of the knee due to improved surgical techniques and prosthetic design, and the desire for minimally invasive surgery. However, patient satisfaction following UKA for lateral compartment disease have been suboptimal with increased revision rates. Robotic-assisted UKA has been shown to improve precision and accuracy of component placement, which may improve outcomes of lateral UKA. The purpose of this study was to compare the outcome of robotic-assisted UKA to conventional UKA for degenerative disease of the lateral compartment with the hypothesis that robotic-assisted lateral UKA results in superior outcomes compared to conventional UKA.

Methods

The institution's joint registry was searched for patients who underwent UKA for limited degenerative disease of the lateral knee compartment between 2004 and 2012 and a total of 125 lateral UKAs were identified. The medical records of all patients were reviewed and assessed for the type of surgical procedure used (robotic-assisted versus conventional), length of hospital stay, Oxford knee score, and occurrence of revision surgery. Preoperative and postoperative radiographs were assessed for tibiofemoral angle, femoral and tibial joint line angle, posterior tibial slope, and orientation of the femoral and tibial components.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XII | Pages 5 - 5
1 Apr 2012
Wakeling C Bracey D
Full Access

The Oxford unicompartmental knee replacement (UKR) was introduced in 1976 with good results. Mobile bearings in the lateral compartment have been associated with unacceptably high bearing dislocation rates, due to greater movement between the lateral femoral condyle and tibia, and the lateral collateral ligament's laxity in flexion. The new domed implant is designed to counter this with a convex tibial prosthesis and a fully-congruent, bi-concave mobile bearing allowing a full range-of-movement (ROM), minimising dislocation risk and bearing wear.

We present complication rates and clinical outcomes for a consecutive series of our first 20 patients undergoing Oxford domed lateral UKR, between June 2006 and August 2009, with minimum 6-month follow-up. There was one unrelated death (31 months post-UKR) and one postop MI. We had no bearing dislocations, infections or loosening nor other complications. All patients had post-op Oxford Knee Scores; eleven had pre-op scores and demonstrated a significant improvement – mean pre-op 22.75 to post-op 35.45 (p=0.01). All achieved full extension with average ROM 116°, mean change in ROM was –2.6°(p=0.6).

This study adds to previous work in confirming a low level of complications with this new procedure (including the early learning curve), particularly bearing dislocation and demonstrates excellent functional outcomes.