Vol. 105-B, Issue SUPP_18 | Pages 5 - 5
1 Dec 2023
Jones M Pinheiro V Laughlin M Borque K Williams A
Full Access

Introduction

To evaluate career length after surgical treatment of combined ACL + medial collateral ligament (MCL) and ACL +posterolateral corner (PLC) surgeries in all elite athletes. Secondly, in a subgroup of male professional footballers to determine career length and competition level after ACL+MCL or ACL+PLC reconstructions and compare this to a cohort who underwent isolated ACL reconstruction (ACL-R) alone.

Methods

A consecutive cohort of elite athletes undergoing combined ACL+MCL surgery and combined ACL+PLC surgery between February 2001 and October 2019 were analysed. A subgroup of male footballers from this population was compared to a previously identified cohort of male, professional footballers having had primary ACL reconstruction without other ligament surgery. A minimum 2-years follow-up was required. Outcome measures were career length and competition level.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 65 - 65
7 Aug 2023
Jones M Pinheiro VH Balendra G Borque K Williams A
Full Access

Abstract

Introduction

The study aims were to demonstrate rates, level, and time taken to RTP in elite sports after ACL reconstruction (ACL-R) and compare football and rugby.

Methods

A retrospective review of a consecutive series of ACL-R between 2005 and 2019 was undertaken. Patients were included if they were elite athletes and were a minimum of 2 years post primary autograft ACL-R. The outcomes measured were return to play (RTP), (defined as participation in a professional match or in national/ international level amateur competition), time to RTP after surgery, and RTP level (Tegner score).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 76 - 76
7 Aug 2023
Borque K Han S Gold J Sij E Laughlin M Amis A Williams A Noble P Lowe W
Full Access

Abstract

Introduction

Persistent medial laxity increases the risk of failure for ACL reconstruction. To address this, multiple reconstruction techniques have been created. To date, no single strand reconstruction constructs have been able to restore both valgus and rotational stability. In response to this, a novel single strand Short Isometric Construct (SIC) MCL reconstruction was developed.

Methods

Eight fresh-frozen cadaveric specimens were tested in three states: 1) intact 2) after sMCL and dMCL transection, and 3) after SIC MCL reconstruction. In each state, four loading conditions were applied at varying flexion angles: 90N anterior drawer, 5Nm tibial external rotation torque, 8Nm valgus torque, and combined 90N anterior drawer plus 5Nm tibial external rotation torque.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 77 - 77
7 Aug 2023
Borque K Han S Gold J Sij E Laughlin M Amis A Williams A Noble P Lowe W
Full Access

Abstract

Introduction

Historic MCL reconstruction techniques focused on the superficial MCL to restore valgus stability while overlooking tibial external rotation and the deep MCL. This study assessed the ability of a contemporary medial collateral ligament (MCL) reconstruction and a deep MCL (dMCL) reconstruction to restore rotational and valgus knee stability.

Methods

Six pairs fresh-frozen cadaveric knee specimens with intact soft tissue were tested in four states: 1) intact 2) after sMCL and dMCL sectioning, 3) contemporary MCL reconstruction (LaPrade et al), and 4) dMCL reconstruction. In each state, four loading conditions were applied at varying flexion angles: 8Nm valgus torque, 5Nm tibial external rotation torque, 90N anterior drawer, and combined 90N anterior drawer plus 5Nm tibial external rotation torque.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 76 - 76
1 Jul 2022
Borque K Jones M Laughlin M Webster E Williams A
Full Access

Abstract

Introduction

The popularity of all-inside meniscal repair devices has led to a shift away from inside-out meniscus repair without comparative studies to support the change. The aim of this study was to compare the failure rate and time to failure of all-inside and inside-out meniscus repair performed in elite athletes.

Methodology

A retrospective review was performed of all elite athletes who underwent meniscal repair, with a minimum of two-year follow-up between 2013 and 2019. Repairs were classified as all-inside or inside-out according to the repair technique. Failure was defined as undergoing a subsequent surgery to address a persistent meniscal tear.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 78 - 78
1 Jul 2022
Borque K Jones M Balendra G Laughlin M Willinger L Williams A
Full Access

Abstract

Introduction

Anterolateral procedures can reduce the risk of re-rupture after ACL reconstruction in high risk patients however, this effectiveness has never been evaluated in elite athletes. The purpose of this study was to evaluate the effectiveness of lateral extra-articular tenodesis in reducing revision rates in ACL reconstructions in elite athletes.

Methodology

A consecutive cohort of elite athletes between 2005 and 2018 undergoing ACLR reconstruction with or without modified Lemaire lateral extra-articular tenodesis were analysed. A minimum of 2 years of follow-up was required. The association between the use of LET and ACL graft failure was evaluated with univariate and multivariate logistic regression models.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 80 - 80
1 Jul 2022
Pinheiro VH Jones M Borque K Balendra G White N Ball S Williams A
Full Access

Abstract

Introduction

Elite athletes sustaining a graft re-rupture after ACL reconstruction (ACL-R) undergo revision reconstruction to enable their return to elite sport. The aim of this study was to determine the rate of return to play (RTP) and competition levels at 2 and 5 years post revision ACL-R.

Methodology

A consecutive series of revision ACL-R in elite athletes undertaken by the senior author between 2009 and 2019 was retrospectively reviewed. Outcome measures were RTP rates and competition level.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 124 - 124
1 Jul 2020
Woodmass J Wagner E Borque K Chang M Welp K Warner J
Full Access

Chronic massive irreparable rotator cuff tears represent a treatment challenge and the optimal surgical technique remains controversial. Superior capsular reconstruction (SCR) has been proposed as a means to provide superior stability to the glenohumeral joint, thus facilitating restoration of shoulder function. However, despite the growing use of SCR there is a paucity of data evaluating the outcomes when performed using a dermal allograft. The purpose of this study was to (1) report the overall survival rate (reoperation and clinical failure) of SCR (2) evaluate for pre-operative factors predicting reoperation and clinical failure.

From January 1, 2015 to November 31, 2017, 65 patients were diagnosed with irreparable rotator cuff tears and consented for a superior capsular reconstruction. These surgeries were performed by 6 surgeons, all fellowship trained in either sports or shoulder and elbow fellowships. Outcomes were graded as excellent, satisfactory, or unsatisfactory using the modified Neer scale. An unsatisfactory result was defined as a clinical “failure”. The Kaplan-Meier survival models were created to analyze reoperation-free and failure-free survival for the entire group. The reconstruction was performed using a dermal allograft. There were 31 patients excluded due to insufficient follow-up (< 6 months), leaving 34 included in this study. The mean follow-up was 12 months (range, 6–23). The average number of prior surgeries was 0.91 (range, 0–5), with 52.9% of patients receiving a prior rotator cuff repair and 38.2% of patients with a prior non-rotator cuff arthroscopy procedure.

The one and two-year survival-free of surgery was 64% and 44% and the one and two-year survival free of failure was 34% and 16% following SCR, respectively. For the patients that underwent a reoperation, 62.5% (n= 5/8) underwent reverse shoulder replacements, 25% (n= 2/8) latissimus dorsi tendon transfers, and 12.5% (n= 1/8) a diagnostic arthroscopy. The average period between the primary and revision surgery was 10.2 months (range, 2.1–18.5). All but two patients (75%, n= 6/8) had at least one surgery prior to the SCR. There were 14/34 (41.2%) patients who experienced pain, weakness, and restricted range of motion. These patients were defined as clinical failures with an unsatisfactory grading on Neer's criteria. Previous surgery predicted reoperation (80% vs 43%, p = 0.03). Female gender predicted clinical failure (100% vs 43%, p < 0 .01).

Superior Capsule Reconstruction performed for large to massive rotator cuff tears has a high rate of persistent pain and limited function leading to clinical failure in 65% (n= 22/34) of patients. The rate of failure is increased in revision cases, female gender and increased Goutallier fatty infiltration of the infraspinatus. Narrowed indications are recommended given the surgical complexity and high rate of early failure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 456 - 456
1 Dec 2013
Borque K Gold J Ismaily S Patel R Incavo S Noble P
Full Access

Purpose:

Knee pain and instability during high demand activities such as stair descent are reported by patients after TKA. Previous studies theorized that this pain is from increased demand on the quadriceps required to stabilize the femur on the tibia. In this study we explore the relationship between implant design, the posterior cruciate ligament (PCL), and AP stability of the knee during stair descent.

Methods:

CTs of 6 fresh-frozen human cadaveric knees (average age: 61 ± 6.5 years) with functioning cruciates were prepared. All specimens were mounted in a computer controlled, 6 DOF simulator programed to apply physiologic muscle loads and flexion/extension moments simulating the highest demand phase of stair descent (terminal swing to initial contact). A contemporary design of TKA was implanted in each specimen by an experienced surgeon. Testing was repeated after implantation of tibial inserts of the CR, CS with and without a PCL and PS designs.