Vol. 99-B, Issue SUPP_22 | Pages 98 - 98
1 Dec 2017
Diefenbeck M Bischoff S Lidén E Poh P van Griensven M Hettwer W
Full Access

Aim

A gentamicin-eluting biocomposite consisting of hydroxyapatite (HA) and calcium sulphate (CaS)*1 can provide effective dead space management and bone formation in chronic osteomyelitis. However, radiographic follow-up after implantation of this biomaterial has shown imaging features previously not described with other comparable bone graft substitutes. Last year we presented preliminary results with a follow-up of 6 months. Now we present the radiographic, µCT and histological one-year follow-up of the critical-size bone defect model in sheep. The aim of this study was to simulate the clinical situation in a large animal model to correlate different imaging techniques used in the clinic (Radiography, CT and MRI scans) with histological finding.

Methods

Standardised bone defects were created in ten Merino-wool sheep (age two to four years). Large drill holes (diameter 2.5cm, depth 2cm, volume approx. 10ml) were placed in the medial femoral condyles of both hind legs and filled with gentamicin-eluting biocomposite. Initially surgery was carried out on the right hind leg.

Three months later, an identical intervention was performed on the contralateral side. Animals were sacrificed at three and six weeks and 4.5, six and twelve months. Radiographs and MRI scans were taken immediately after sacrifice. Filled bone voids were harvested en-block and analysed using µCT, and histology.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 68 - 68
1 Dec 2016
Hettwer W Bischoff S Schubert H Liden E Diefenbeck M
Full Access

Aim

A gentamicin-eluting biocomposite consisting of hydroxyapatite and calcium sulfate1 can provide effective dead space management in chronic osteomyelitis. However, radiographic follow-up after implantation of this novel material has consistently shown evidence of several unique imaging features previously not described with other comparable bone graft substitutes. Conclusive interpretation of these newly described imaging features is difficult as long term follow-up and histological correlation is not yet available. The aim of this study was to establish a large animal model, closely simulating the clinical situation in order to permit further analysis of imaging features in correlation with histological progression of bone remodelling.

Method

Standardised bone defects were created in ten Merino-wool sheep (age: two to four years). Large drill holes (diameter 2.5cm, depth 2cm, volume approx. 10ml) were placed in the medial femoral condyles of both hind legs and filled with a gentamicin antibiotic eluting bone graft substitute*. Initially surgery was carried out on the right hind leg. Three months later, an identical intervention was performed on the contralateral side. With sacrifice planned after six or twelve months, bone voids three, six, nine and twelve months post-implantation are obtained for evaluation. The study was approved by the Animal Care Committee of Thuringia, Germany.