Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 2 - 2
12 Dec 2024
Goel A Bidwai R Singh V Malaviya S Kumar K Cairns D Barker S Khan K
Full Access

Objective

We aimed to analyse the clinical outcomes and survivorship of anatomic total shoulder arthroplasty using a stemless humeral component with cemented pegged polyethylene glenoid performed with the technique of eccentric reaming to partially correct retroversion. These results were then compared with TSA using the same implant for end-stage shoulder arthritis with a normal version of the native glenoid.

Design and methods

A retrospective case series was performed using a prospectively collected database of anatomic TSA patients operated at Woodend General Hospital, Aberdeen, UK. Between 2010 and 2019, 107 total shoulder arthroplasties (TSA) were done using standard anatomic stemless TSA implants (Affinis Short, Mathys Ltd, Bettlach, Switzerland) in 98 patients. Standardized preoperative and postoperative shoulder radiological imaging for glenoid retroversion was collected. Depending on the angle of native glenoid version, patients were divided into retroverted and non-retroverted glenoid as per the Walch Classification. To assess the radiological outcome at the final follow-up, radiolucency was assessed on the glenoid and humeral side using the Lazarus grading. The final clinical and radiologic outcome from the retroverted group was compared with the population with a non-retroverted glenoid. Five TSAs were excluded from the analysis as they did not have satisfactory postoperative radiographs. Hence, a total of 102 shoulders were available for analysis.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 2 - 2
13 Mar 2023
Hoban K Yacoub L Bidwai R Sadiq Z Cairns D Jariwala A
Full Access

The COVID-19 pandemic presented a significant impact on orthopaedic surgical operating. This multi-centre study aimed to ascertain what factors contributed to delays to theatre in patients with shoulder and elbow trauma.

A retrospective cohort study of 621 upper limb (shoulder and elbow) trauma patients between 16/03/2020 and 16/09/2021 (18-months) was extracted from trauma lists in NHS Tayside, Highland and Grampian and Picture Archiving and Communication Systems (PACS).

Median patient age =51 years (range 2-98), 298 (48%) were male and 323 (52%) female. The commonest operation was olecranon open reduction internal fixation (ORIF) 106/621 cases (17.1%), followed by distal humerus ORIF − 63/621 (10.1%). Median time to surgery was 2 days (range 0-263). 281/621 (45.2%) of patients underwent surgical intervention within 0-1 days and 555/621 patients (89.9%) had an operation within 14 days of sustaining their injury. 66/621 (10.6%) patients waited >14 days for surgery. There were 325/621 (52.3%) patients with documented evidence of delay to surgery; of these 55.6% (181/325) were due to amendable causes. 66/325 (20.3%) of these patients suffered complications; the most common being post-operative stiffness in 48.6% of cases (n=32/66).

To our knowledge, this is the first study to specifically explore effect of COVID-19 pandemic on upper limb trauma patients. We suggest delays to theatre may have contributed to higher rates of post-operative stiffness and require more physiotherapy during the rehabilitation phase. In future pandemic planning, we propose dedicated upper-limb trauma lists to prevent delays to theatre and optimise patients’ post-operative outcomes.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 5 - 5
1 Nov 2022
Bidwai R Goel A Khan K Cairns D Barker S Kumar K Singh V
Full Access

Abstract

Aim

Excessive glenoid retroversion and posterior wear leads to technical challenges when performing anatomic shoulder replacement. Various techniques have been described to correct glenoid version, including eccentric reaming, bone graft, posterior augmentation and custom prosthesis. Clinical outcomes and survivorship of a Stemless humeral component with cemented pegged polyethylene glenoid with eccentric reaming to partially correct retroversion are presented.

Patients and Methods

Between 2010– 2019, 115 Mathys Affinis Stemless Shoulder Replacements were performed. 50 patients with significant posterior wear and retroversion (Walch type B1, B2, B3 and C) were identified. Measurement of Pre-operative glenoid retroversion and Glenoid component version on a post op axillary view was performed by method as described by Matsen FA. Relative correction was correlated with clinical and radiological outcome.