Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 157 - 157
1 Dec 2013
Rathod P Deshmukh A Bhalla S Rodriguez J
Full Access

INTRODUCTION

Acetabular cup orientation is an important element of Total Hip arthroplasty (THA). The purpose of this retrospective case-control study was to compare variability of acetabular cup placement between THA performed via Direct Anterior Approach (DAA) with fluoroscopy in supine position and posterior approach (PA) in lateral position without use of fluoroscopy.

METHODS

Radiographic and clinical records of THAs performed by a single, high volume arthroplasty surgeon at one institution were reviewed. Patients with similar design of uncemented acetabular cup, femoral component and bearing surface were included to form two groups. PA group consisted of 300 THAs performed from May 2006 to June 2009. DAA group consisted of 300 THAs performed from Oct 2009 to Oct 2011 excluding first 100 cases to eliminate the influence of learning curve. Radiographic analysis was done by two independent blinded observers to determine cup inclination and anteversion (Liaw et al) on standardized, 6 week postoperative, standing anteroposterior pelvic radiographs using Picture Archiving and Communication System software (PACS).