Protocols for processing of tissue from arthroplasty infections vary and might affect the recovery of bacteria. We compared homogenization, bead beating and enzymatic disruption for recovery of live bacteria from tissue samples. Suspensions of Staphylococcus aureus and Escherichia coli were prepared as controls. Three samples were taken from each and the first was bead beaten, the second homogenized, and Proteinase K was added for 10 and 30 minutes to the third sample before culturing. In addition, artificially inoculated pork tissue and known infected human tissue samples were processed by either homogenization or bead beating prior to cultures and results were compared. Number of cycles of bead beating and homogenization and duration of Proteinase K treatment had significant effects. Bead beating for 2 and 4 cycles reduced the yield of S.aureus to 52% and 20% of control, and E.coli to 33% and 8%. Homogenization for 2 and 4 cycles reduced S.aureus to 86% and 65% of control, and E.coli to 90% and 87%. Proteinase K for 10 minutes and 30 minutes reduced the yield of S.aureus to 75% and 33% of control, and E.coli to 91% and 49% respectively. Inoculated Pork tissue showed a reduction in S.aureus recovery of 90% for bead beating compared to homogenization, and 80% in the case of E.coli. Bead beating of infected human tissue samples reduced the yield by 58% compared to homogenization. Bead-beating is a common recommended method of processing tissue from arthroplasty cases. However, even though it produces a homogeneous sample, it does so at the cost of significant loss of viable bacteria. Homogenization and 10 minutes of Proteinase K incubation are almost equivalent, but the homogenizer is preferred being more controllable and cheaper. This should help to define guidelines for diagnosing infections using tissue samples.
Metal instrumentation (rods and screws) is used to stabilise the spine after trauma, malignancy or deformity. Approx 3% become infected often necessitating removal of metal. At surgery tissue samples and metal are removed for culture, but many clinical laboratories are not equipped to process metal or use simple culture methods. The causative bacteria exist as biofilms on the metal and they are often anaerobic and slow-growing, so conventional culture methods often fail to detect them. Also, they are common contaminants leading to diagnostic uncertainty. We have established a laboratory protocol to overcome these problems. Removed metalwork was sonicated and the sonicate centrifuged and the supernatant discarded. Quantitative aerobic and anaerobic culture of the resuspended pellet for 14 days and microscopy were carried out. Metalwork from 11 suspected infected cases was culture-positive (median 2857, 60–5000cfu/mL). Microscopy revealed an infection due to Candida albicans that would not have been detected otherwise. Bacteria were isolated from 8 of 10 non-infected cases (median 15, 0–35 cfu/mL). Conventionally processed samples failed to grow in 4 infected cases. (cfu/mL infected vs noninfected cases p=0.0093) Micro-organisms on spinal metalwork grow as biofilms and they require sonication to dislodge them. The causative bacteria are slow-growing and P acnes is anaerobic and requires prolonged incubation. S epidermidis and P acnes are common contaminants and quantitative culture helps to distinguish pathogens from contaminants, removing the diagnostic uncertainty that conventional methods give. Microscopy of the sonicate can reveal micro-organisms that fail to grow on culture. We recommend that sonication of metalwork, prolonged anaerobic incubation and quantitative culture be adopted to improve diagnostic clarity for spinal instrumentation infections.
To test the hypothesis that surface skin swabs taken after skin preparation with alcoholic povidone iodine (APVPI) would not grow bacteria, whereas full thickness biopsies taken from the line of surgical incision would grow bacteria. Informed consent was obtained from 44 patients undergoing primary hip (n=13) and knee (n=31) arthroplasty. Each received antimicrobial prophylaxis before skin preparation with APVPI under laminar flow. After the APVPI had dried, a skin swab and a full thickness 8mm x 4mm elliptical skin biopsy were taken from the line of incision. The skin swab was rolled in 5mL anaerobe basal broth to inactivate the APVPI, incubated at 37 degrees and checked for growth for 2 weeks. One half of the skin biopsy was snap frozen and used for gram and nitroblue tetrazolium staining. The other half was placed into 5mL of anaerobe basal broth, incubated at 37 degrees and monitored for growth for 2 weeks.Aim
Method
Antibiotic loaded bone cement spacers are used as an adjunct to treatment in 2-stage arthroplasty revisions. If release of the correct choice of antimicrobials is optimised, systemic therapy might be curtailed and emergence of resistance minimised. Aims: To determine the elution period of antimicrobials from bone cement with and without a copolymer, polyvinylpyrrolidone (PVP) and to limit resistance development by the use of two or more antimicrobials. Triclosan, gentamicin and clindamycin with and without (PVP) in CMW bone cement, was tested against six bacteria using serial plate transfer.Background
Methods
Deep infection rates of 1 - 2% following primary hip and knee arthroplasty are mainly due to endogenous contamination of the surgical site from bacteria within the patient's own skin. However surgical skin preparation removes only bacteria from the surface of the skin, leaving viable bacteria in the deeper layers of the skin within hair follicles and sweat and sebaceous glands. The aim of our study was to test the hypothesis that surface skin swabs taken after skin preparation with alcoholic povidone iodine would not grow bacteria, whereas full thickness biopsies taken from the line of surgical incision would grow bacteria. Under LREC approval, informed consent was obtained from 22 patients undergoing primary hip (n=9) or knee (n=13) arthroplasty. All patients received intravenous antibiotic prophylaxis at the time of induction of anaesthesia. After surgical skin preparation with alcoholic povidone iodine, a surface skin swab and full thickness skin biopsy, using an 8mm x 4 mm elliptical punch, were taken. The swab culture was incubated aerobically and anaerobically at 37°C. The skin biopsy was cut aseptically in half. One half was crushed using artery forceps, placed in 5mL anaerobe basal broth and incubated anaerobically at 37°C. The other half of the skin biopsy was frozen in isopentane and gram – stained after sectioning.Background
Methods
Open fractures occur with an annual incidence of 11.5 per 100,000 (6900 pa in UK). Infection rates, even with intravenous broad-spectrum antibiotics, remain as high as 22%. For this reason necessary bone grafting is usually delayed until soft-tissue cover of the bone injury is achieved. A biodegradable bone graft that released sustained high concentrations of antibiotics and encouraged osteogenesis, that could be implanted safely on the day of injury would reduce infection rates and avoid reoperation and secondary grafting. The non –union rate (approx 350 pa in UK) should also be reduced. Such a graft, consisting of a PLA/PGA co –polymer and containing antibiotics, is under development and here we report assessment of spectrum and duration of antimicrobial activity and effect of addition of antibiotics on mechanical properties. Varying concentrations of gentamicin, colistin, clindamycin and trimethoprim, singly and in combination, were added to the copolymer and test pieces were made. These were then tested using an established method (SPTT) which determines degree and duration of antimicrobial activity as well as risk of emerging resistance. Test bacteria were Staphylococcus epidermidis, Staphylococcus aureus, MRSA and Escherichia coli. Mechanical properties (compressive strength and porosity) were determined using established methods.Introduction
Methods
Prosthetic joint infection (PJI) is an increasing problem and management commonly involves prosthesis removal with serious consequences. Biofilm-forming staphylococci are the most common causative organisms with Staphylococcus aureus being most virulent and methicillin-resistant Staphylococcus aureus (MRSA) more than doubling the infection mortality rate. Bacterial adhesion is an essential primary event in biofilm formation and infection establishment. The development of a novel combination vaccine programme to prevent staphylococcal PJI by directing antibody against factors involved in adhesion and biofilm formation, and investigation of S. aureus binding-domains as potential vaccine components for adhesion inhibition is described. Selected target antigens included the S. aureus fibronectin-binding protein (FnBP) and iron-regulated surface determinant (IsdA), which have been shown to be important for infection establishment and predominantly bind to host fibronectin and fibrinogen respectively. Escherichia coli clones harbouring recombinant S. aureus binding-domain DNA sequences were used for expression and purification of antigen domains. In vitro antibody evaluation determined whether immune inhibition of bacteria - ligand binding can significantly impact on attachment to plasma-conditioned biomaterial (in presence of other bacterial ligands). Adhesion of homologous and heterologous (MRSA PJI isolate) S. aureus to plasma-conditioned steel was significantly reduced (approximately 50 percent average reduction, p <
0.0001) when pre-exposed to anti-rFnBP-A antiserum (with pre-immune serum control) that was 50-fold more dilute than the actual titre from immunisation. Inhibition was related to ligand presence but not staphylococcal Protein A, and reduced adhesion was not observed with the mutant strain, indicating specific inhibitory antibody involvement, and demonstrating for the first time the potential of rFnBP-A for prevention of S. aureus PJI. Adhesion-inhibitory activity was also observed with a purified IgG-fraction of rIsdA antiserum but this activity appeared to be masked by non-IsdA - related interactions when non-IgG - purified antiserum was assessed.
The implications of this are that vaccination using this peptide might be expected to protect patients about to undergo elective arthroplasty from infection with S aureus whatever its antibiotic susceptibility, so offering a realistic solution to the problem of increasing resistance.
To determine the quantitative adherence and biofilm development of P. acnes on titanium compared to surgical steel. To assess the subsequent effect of penicillin, the therapeutic drug of choice, on mature P. acnes biofilms.
All four NSAIDs reduced The effect on adherence was confined to unconditioned PMMA. The effect on biofilm formation and on established biofilms appeared to be related to that on growth and viability. On these grounds, NSAIDs appear to have a limited prospect for use in prevention or treatment of
Approximately 1% of joint replacement operations are complicated by infection. Thirty percent of these infections are due to
Most infections in arthroplasty are caused by staphylococci, about half being due to Antibodies to recombinant sequences of Fnbp and Fgbp were raised in rabbits. A strain of Each antibody reduced the number of bacteria binding to all three materials by greater than 50%. Combining the two antibodies gave similar results to those when they were used individually. These preliminary results suggest that while further research is required, vaccination aimed at blocking bacterial attachment to conditioning film on implanted prostheses might reduce the incidence of