Aim

Treatment of complicated wound healing after total joint arthroplasty is controversial. What exactly constitutes prolonged wound drainage is matter of debate and recommendations to manage it vary considerably. Nonoperative measures are often recommended. If drainage persists, surgery may be indicated. To further intricate decision-making, differentiating superficial from deep surgical site infection is also controversial and inherently complex. Specific cutoffs for synovial fluid leukocyte count and blood C-reactive protein (CRP) in the acute stage have been suggested as a way to superficial infection requiring superficial wound washout from deep infection requiring a formal debridement, antibiotics and implant retention (DAIR) procedure. The goal of this study is to analyze clinical and laboratory findings of an institutional protocol of “aggressively” proceeding with formal DAIR in all patients with complicated wound healing

Method

Our indications for DAIR in suspected acute postoperative periprosthetic joint infection (PJI) are: 1)prolonged wound drainage and CRP upward trend after day-3; 2)persistent wound drainage by day-10 regardless of CRP; 3)wound healing disturbance (e.g. “superficial” infection, “superficial” skin necrosis) anytime in early postoperative weeks. We retrospectively evaluated patients undergoing DAIR in the first 60 postoperative days between 2014–2018. Patients without multiple deep tissue cultures obtained intraoperative were excluded. Deep infection was defined by at least two positive deep tissue cultures or one positive deep culture and positive leukocyte count (>10,000 cells/mL or >90% PMN).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 54 - 54
1 Dec 2019
Ribau A Carvalho AD Barbosa TA Abreu M Soares DE Sousa R
Full Access

Aim

C-reactive protein(CRP) and erythrocyte sedimentation rate(ESR) are non-specific markers with variable reported accuracy in the diagnosis of prosthetic joint infection(PJI). They are often used as a part of the initial diagnostics as they are widely available and inexpensive. Given its high false-negative rate, CRP is an insufficient screening tool for PJI especially in low virulence microorganisms. Nevertheless, many advocate ESR offers no added advantage and is useless in this setting. Our goal is to determine if the combined measurement of ESR and CRP offers increased sensitivity for the preliminary screening of PJI over isolated CRP measurement.

Method

We retrospectively evaluated every single- or first-stage for presumed aseptic or known infected revision total hip/knee arthroplasty procedures between 2013–2018. Cases without preoperative CRP and ESR measurement as well those without synovial fluid for differential leukocyte count and/or no multiple cultures including sonication of removed implant obtained during surgery were excluded. Diagnostic accuracy was compared against two different PJI definitions: 2013 International Consensus Meeting and ProImplant Foundation definitions.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 73 - 73
1 Dec 2019
Carvalho AD Ribau A Barbosa TA Santos C Abreu M Soares DE Sousa R
Full Access

Aim

Antibiotic loaded spacers are often used during a two-stage exchange for periprosthetic joint infections (PJI) both for its mechanical properties and as a means for local antibiotic delivery. The main goal of this study is to compare the rate of positive cultures during reimplantation with the use of different antibiotic loaded spacers: aminoglycoside only vs. combined glycopeptide/aminoglycoside vs. combined glycopeptide/carbapenem/aminoglycoside.

Method

We retrospectively evaluated every two-stage exchange procedures for infected hip/knee arthroplasty between 2012–2018. Microbiological findings in the first and second stage were registered as well as the type of spacer and antibiotic(s) used. Cases in whom no cultures were obtained during reimplantation and cases without sufficient data on antibiotic(s) used in cement spacers were excluded.