Total hip arthroplasty (THA) is one of the preferable solutions for regaining ambulatory activity for patients with end-stage osteoarthritis, and the procedure is well developed technically and large numbers of patients benefit from THA worldwide. However, despite the improvements in implant designs and surgical techniques, revision rates remain high, and the number of revisions is expected to increase in the future as a result of the increase in the volume of primary THA and the increase in the proportion of younger, more active patients who are likely to survive longer than their prosthetic implants. In revision THA, associated loss of bone stock in the acetabulum presents one of the major challenges. The aim of the present study was to analyze the clinical and radiographic outcomes and Kaplan-Meier survivorship of patients underwent revision surgeries of the acetabular cup sustaining aseptic loosening. We reviewed consecutive 101 patients (120 hips; 10 men 11 hips; 91 women 109 hips; age at surgery, 66 years, range, 45–85) who underwent acetabular component revision surgery, at a follow-up period of 14.6 years (range, 10–30). For the evaluation of the state of the acebtabulum, acetabular bony defects were classified according to the classification of the AAOS based on the intraoperative findings as follows; type I [segmental deficiencies] in 24 hips, type II [cavity deficiency] in 48 hips, type III [combined deficiency] in 46, and type IV [pelvic discontinuity] in 2. Basically, we used the implant for acetabular revision surgery that cement or cementless cups were for the AAOS type I acetabular defects, cementless cup, or cemented cup with reinforcement device were for type II, cemented cup with reinforcement device were for type III. Follow-up examination revealed that Harris Hip score improved from 42.5±7.8 points before surgery to 76±16.2 points (p<0.05). The survival rates of the acetabular revision surgery with cemented cups, cementless cups, and cemented cups with reinforcement devices were 65.1%, 72.8%, and 79.8%, respectively, however, there was no significant differences between the groups. There were nine cases, which failed in the early stage in the groups of cementless cups and cemented cups with reinforcement devices, because of the instability of the cementless cups or breakage of reinforcement plates caused by inadequate bone grafting. We conclude that the usage of the cementless cups for type I and II acetabular bony defects, and the cemented cups with reinforcement devices for type III bony defects will demonstrate durable long-term fixation in case of adequate contact between acetabular components and host-bone with restoration of bone stock by impaction bone grafting.
CONCLUSION: In our model the prevailing osmolality was a powerful regulator of GAG accumulation by cultured nucleus cells. In vivo prevailing osmolality is governed by GAG concentration. These results thus indicate GAG synthesis rates are regulated by GAG concentration, with implications both for the aetiology of degeneration and for tissue engineering.
We followed 66 total hip arthroplasties using a cement-less Omniflex femoral component with different surface morphology in 51 patients for a mean of 98 months (72 to 138). There were 57 women and nine men, and the mean age of the patient at the time of operation was 55.4 years (39 to 70). Preoperative diagnosis was osteoarthritis secondary to congenital hip dislocation and dysplasia in 64 hips, rheumatoid arthritis in two hips. This series was divided into three groups according to the extent of surface treatment in the proximal part of the femoral component. A circumferential Hydroxyapatite or titanium plasma-spray coated Omniflex stem was used in 33 hips (Group A). A patchy titanium-beads coated stem and a smooth surfaced stem of the same design were used in 25 hips (Group B) and eight hips (Group C), respectively. Clinically, the mean Harris Hip Score was 54 points preoperatively, which improved to 89 points at the latest follow-up. Incidence of thigh pain was the lowest in Group A ( 6%) in comparison with in Group B (28%) and Group C (25%). Radiographically, the aseptic loosening rate of the femoral component was none in Group A, 16% in Group B and 75% in Group C. Incidence of femoral osteolysis was almost the same rate among the three groups; 38% in Group A, 40% in Group B, and 50% in Group C. However only in Group A, no Osteolysis was found distal to the lesser trochanter level. The femoral revision was performed in two hips of Group C. This study elucidated that the extent of surface treatment would be one of the important factors to influence the stem stability and the occurence of femoral osteolysis.
Fit with the proximal femoral cortices is critical to the success of cementless femoral stems in total hip arthroplasty. Conventional femoral stems are often designed from the average geometry of the normal femora. Hip disease in Japan, however are predominantly associated with Osteoarthritis secondary to congenital hip dislocation or sublux-ation of the hip. We developed a new model of proximal fitting cementless total hip stem, the so-called FMS (for Fukui Medical School) stem, based on the endosteal geometry of Japanese proximal femoral canal with developmental dysplasia of the hip. The proximal third surface of this stem model was circumferentially hydroxyapatite-coated. One hundred-two hips in 85 patients underwent cement-less total hip arthroplasty with the new stems were studied with a minimum follow-up period of two years. There were 78 women and 8 men, and the mean age of the patient at the time of operation was 56.4 years. Preoperative diagnosis was developmental dysplasia of the hip in 94 hips, osteonecrosis in 6 hips and rheumatoid arthritis in 2 hips. The mean follow-up period was 43 months (24 to 74). Clinically, the mean Harris Hip Score was 48 points preoperatively, which improved to 92 points at the latest follow-up. Thigh pain was present in two hips (2%) at the latest follow-up although in six hips (6%) in the study group at one-year follow-up. Radiographically, according to Engh’s criteria, spot welds associated with osseointegration were observed around the inferior border of the proximal coating in all hips. We have observed no loosening or failure of the stems at the latest follow-up. Our results indicate that the new model of proximal fitting cementless fem
To investigate the histological findings for a herniated cervical intervertebral disc that produces a high intensity signal on MR images. Fifty-five herniated cervical intervertebral discs harvested from 49 patients were histologically and immunohistochemically examined. Herniated cervical intervertebral discs with a high intensity signal on axial T2 MR images were classified as a globular, linear, or mosaic type. The specimens were embedded with paraffin using standard procedures. Serial 4 μm thick cryostat sagittal sections were prepared for HE, toluidine blue, PAS, and Elastica van Gieson staining as well as immunohistochemical study. The monoclonal antibodies used were specific for human CD68, IL-1β, and TNF-α. Preoperative axial T2 MR images indicated that 3 discs had no high intensity signal and 52 discs had a high intensity signal; 22 discs were globular, 20 were linear, and 10 were mosaic. Histopathologically, high intensity signal areas in globular discs consisted of nucleus pulposus surrounded by macrophages. These macrophages and the chondrocytes around them expressed IL-1β and TNF-α. Almost all of the patients with a globular disc, had had severe radicular pain. For the linear disc patients, the fissure was observed consistent with the high intensity signal. A substance that would produce positive results for PAS staining was rarely observed. The current histological study suggests that a globular type of disc with a high intensity signal on an axial T2 MR image consisted of a nucleus pulposus. Results demonstrated that, in these herniated discs, infiltrated macrophages and chondrocytes expressed inflammatory cytokines, and these reactions were associated with radicular pain. In contrast, linear and mosaic discs showed no obvious substance corresponding with the high-intensity zone, but the fissure was observed. It appears that a high-intensity zone for a linear or mosaic type of disc suggested of a fluid-filled area and/or mucoid fluid.