Aims. The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. Methods. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a
INTRODUCTION. Wedge femoral stems used in total hip arthroplasty (THA) have evolved with modifications including shorter lengths, reduced distal geometries, and modular necks. Unlike fit and fill stems which contact most of the metaphysis,
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMD. 119 patients were randomized to receive either a proximally coated dual
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual
Introduction. Cementless
INTRODUCTION. Immediate post-operative stability of a cementless hip design is one of the key factors for osseointegration and therefore long-term success [1]. This study compared the initial stability of a novel, shortened, hip stem to a predicate standard
A novel cementless tapered wedge femoral hip implant has been designed at a reduced length and with a geometry optimized to better fit a wide array of bone types (Accolade II, Stryker, Mahwah, USA). In this study, finite element analysis (FEA) is used to compare the initial stability of the new proposed hip stem to predicate
Background. A stem sitting proud (SP) or that above the final rasp position remains in some patients who undergo hip replacement using proximally coated
Introduction:. Subsidence of cementless femoral stems in total hip arthroplasty (THA) has been associated with poor initial fixation and subsequent risk of aspectic loosening. There is limited literature on how subsidence of cementless, proximally porous coated,
Non-cemented
Purpose. While changes in lower limb alignment and pelvic inclination after total hip arthroplasty (THA) using certain surgical approaches have been studied, the effect of preserving the joint capsule is still unclear. We retrospectively investigated changes in lower limb alignment, length and pelvic inclination before and after surgery, and the risk of postoperative dislocation in patients who underwent capsule preserving THA using the anterolateral-supine (ALS) approach. Methods. Between July 2016 and March 2018, 112 hips (non-capsule preservation group: 42 hips, and capsule preservation group: 70 hips) from patients with hip osteoarthritis who underwent THA were included in this study. Patients who underwent spinal fusion and total knee arthroplasty on the same side as that of the THA were excluded. Using computed tomography, we measured lower limb elongation, external rotation of the knee, and femoral neck/stem anteversion before operation and three to five days after operation. We examined the pelvic inclination using vertical/transverse ratio of the pelvic cavity measured by X-ray of the anteroposterior pelvic region in the standing position before and six to 12 months after operation. All operations were performed using the ALS approach and
Introduction. Femoral component loosening is one of the most common failure modes in cementless total hip arthroplasty (THA). Patient age, weight, gender, osteopenia, stem design and Dorr-C bone have all been proposed as risk factors for poor fixation and subsequent stem subsidence and poor outcome. With the increased popularity of CT-based assistive technologies in THA, (Stryker MAKO and Corin OPSTM), we sought to develop a technique to predicted femoral stem fixation using pre-operative CT. Methods. Fourteen patients requiring THA were randomly selected from a previous study investigating component alignment. Mean age was 64 (53 to 76), and 57% were female. All patients received pre-operative CT for 3D dynamic templating (OPSTM), and a TriFit stem and Trinity cup (Corin, UK) implanted through a posterior approach. Post-operatively, patients received an immediate CT and AP x-ray prior to leaving the hospital, and a 1-year follow-up x-ray. On both the immediate post-op x-ray and 1-year follow-up x-ray, the known cup diameter was used to scale the image. On both images, the distance between the most superior point of the greater trochanter and the shoulder of the stem was measured. The difference was recorded as stem subsidence. Subsidence greater than 4mm was deemed clinically relevant. The post-operative CT was used to determine the precise three-dimensional placement of the stem immediately after surgery by registering the known 3D implant geometry to the CT. For each patient, the achieved stem position from post-op CT was then virtually implanted back into the pre-operative OPSTM planning software. The software provides a colour map of the bone density at the stem/bone interface using the Hounsfield Units (HU) of each pixel of the CT [Fig. 1]. Blue represents low density bone transitioning through to green and then red (most dense). Results. Mean stem subsidence was 2.1mm (0.2mm to 11.1mm). Two patients had clinically relevant subsidence. The first stem in a 68M subsided 11.1mm. The second in a 58M subsided 5.0mm. Both density colour plots had significant areas of blue (low density bone) around the proximal portion of the stem, with minimal medium/high density fixation when compared to the stems with minimal subsidence. Discussion. Using the Hounsfield units of the CT scan as an indicator for bone density, we were able to predict poor implant fixation and subsequent subsidence in a
Introduction. The origins of the uncemented
The Taperloc Microplasty stem design was based on that of the Taperloc stem with flat tapered wedge and the distal portion of the Taperloc stem was shortened by 35mm. We report the minimum two-year follow up (mean, 26 months) of 68 primary total hip arthroplasty using the Taperloc Microplasty stem. 39 Magnum acetabular cups and 29 M2a Taper acetabular cups were inserted with metal on metal articulation. The series comprised 67 patients (20 men, 47 women) with a mean age at operation of 65 years (31 to 85). The principal diagnosis was osteosrthritis. Their mean JOA Hip Score improved significantly from 36 points preoperatively to 96 points at two-year follow up. Radiological asseement showed good bony stability in all implants. There was one case of post operative anterior dislocation. We did not see intra-operative fracture previously reported for this implant. There were no clinical and radiological complications related to MOM articulation. This short-term follow up study demonstrates that the clinical outcome of the Tapeloc Microplasty stem is comparable with that of standard Taperloc stem and other flat
Intra-operative fractures of the femur are on the rise mainly due to the increased use of cementless implants and the desire to get a tight press fit. The prevalence has been reported to be between 1–5% in cementless THAs. The key to preventing these fractures is to identify patients at high risk and careful surgical technique. Surgical risk factors include the use of cementless devices, revision hip surgery, the use of flat tapered wedges and MIS surgery. Patient factors that increased risk include increasing age, female gender, osteopenia and rheumatoid arthritis. These risk factors tend to be additive and certainly when more than one is present extra caution needs to be taken. Surgical technique is critical to avoid these intra-operative fractures. Fractures can occur during exposure and dislocation, during implant removal (in revision THA), during canal preparation and most commonly during stem insertion. In both primary, and especially in revision, THA be wary of the stiff hip in association with osteopenia or osteolysis. These patients require a very gentle dislocation. If this cannot be achieved, then alteration of the standard approach and dislocation may be needed. Examples of these include protrusion with an osteopenic femur and revision THA with a very stiff hip with lysis in the femur. Lastly, in cases with retained hardware, dislocate prior to removing plates and screws. After dislocation, the next challenge is gentle preparation of the femoral canal. A reasonable exposure is required to access the femoral canal safely. MIS procedures do not offer good access to femoral canal and this probably results in increased risk of fracture during broaching or implant insertion. When broaching, stop when broach will not advance further. When inserting a
INTRODUCTION. Femoral stem impingement can damage an acetabular liner, create polyethylene wear, and potentially lead to dislocation. To avoid component-to-component impingement, many surgeons aim to align acetabular cups based on the “Safe Zone” proposed by Lewinnek. However, a recent study indicates that the historical target values for cup inclination and anteversion defined by Lewinnek et al. may be useful but should not be considered a safe zone. The purpose of this study was to determine the effect of altering femoral head size on hip range-of-motion (ROM) to impingement. METHODS. Ten healthy subjects were instrumented and asked to perform six motions commonly associated with hip dislocation, including picking up an object, squatting, and low-chair rising. Femur-to-pelvis relative motions were recorded throughout for flexion/extension, abduction/adduction, and internal/external rotation. A previously reported custom, validated hip ROM three-dimensional simulator was utilized. The user imports implant models, and sets parameters for pelvic tilt, stem version, and specific motions as defined by the subjects. Acetabular cup orientations for abduction and anteversion combinations were chosen. The software was then used to compute minimum clearances or impingement between the components for any hip position. Graphs for acetabular cup abduction vs. anteversion were generated using a
The aim was to study the evolution of radiographic patterns of osteointegration of
Cementless femoral components have an excellent track record that includes efficient implantation and long-term survival, thus are the predominant stem utilised in North America. Femoral component stability and resistance to subsidence are critical for osseointegration and clinical success. Implant design, surgical technique, anatomic fit, and patient characteristics, such as bone quality, can all effect initial implant stability and resistance to subsidence. Variability in stem shape and in the anatomy of the proximal femoral metaphysis has been implicated in the failure of some stem designs. Biologic fixation obtained with osseointegration of cementless implants may improve implant longevity in young, active, and obese patients. Lack of intimate fit can lead to clinical complications such as subsidence, aseptic loosening, and peri-prosthetic fracture. Currently, there are several stem designs, all of which aim to achieve maximal femoral stability and minimal subsidence and include: Fit and Fill / Double Taper Proximally Porous Coated Stems; Parallel Sided Taper Wedge or “Blade” Stems; Wagner Style Conical Shape Splined Titanium Stems; Tapered Rectangular Cross-Section Zweymuller Stem; Fully-Porous Coated Stems; Modular Proximal Sleeve Fluted Stem; Anatomic Proximally Porous Coated Stems. The majority of patients with relatively straightforward anatomy can be treated with any of the aforementioned femoral implant types. However, more complicated femoral anatomy frequently requires a particular implant type to maximise stability and promote osseointegration. Stems with femoral deformity in the meta-diaphyseal region may require a shorter stem in order to avoid an osteotomy. Distorted femoral anatomy typically seen in childhood diseases, such as dysplasia, may require a modular proximal sleeve tapered fluted stem or Wagner style cone stem to impart optimal stem anteversion separate from the native femoral neck version. The most severe forms of dysplasia may require a shortening osteotomy and subsequent distal fixation and neck version flexibility, which can be addressed with a modular proximal sleeve fluted or fully porous coated stem. A stovepipe or osteoporotic femur may require a stem that engages more distally such as a conical splined tapered stem, a fully porous coated stem or even a cemented stem to achieve adequate stability. Finally, obese patients are a particular challenge and emerging data suggests that a morphologically based parallel-sided
Intra-operative fractures of the femur are on the rise mainly due to the increased use of cementless implants and the desire to get a tight pressfit. The prevalence has been reported to be between 1–5% in cementless total hip arthroplasties (THAs). The key to preventing these fractures is to identify patients at high risk and careful surgical technique. Surgical risk factors include the use of cementless devices, revision hip surgery, the use of flat tapered wedges and MIS surgery. Patient factors that increased risk include increasing age, female gender, osteopenia and rheumatoid arthritis. These risk factors tend to be additive and certainly when more than one is present extra caution needs to be taken. Surgical technique is critical to avoid these intra-operative fractures. Fractures can occur during exposure and dislocation, during implant removal (in revision THA), during canal preparation and most commonly during stem insertion. In both primary and especially in revision THA, be wary of the stiff hip in association with osteopenia or osteolysis. These patients require a very gentle dislocation. If this cannot be achieved, then alteration of the standard approach and dislocation may be needed. Examples of these include protrusion with an osteopenic femur and revision THA with a very stiff hip with lysis in the femur. Lastly, in cases with retained hardware, dislocate prior to removing plates and screws. After dislocation, the next challenge is gentle preparation of the femoral canal. A reasonable exposure is required to access the femoral canal safely. MIS procedures do not offer as good access to femoral canal and this probably results in increased risk of fracture during broaching or implant insertion. When broaching, stop when broach will not advance further. When inserting a
INTRODUCTION:. Short femoral stems are receiving increasing attention for less invasive total hip replacement (THR). The purpose of this study is to report our initial experience with a short modular femoral (SMF) stem at a minimum two-year follow up. METHODS:. Twenty-six primary total hip arthroplasties (THAs) using the SMF stem were performed between August 2009 and January 2010. Patients were evaluated clinically with Harris Hip Score (HHS) and radiographically up to two years. Radiographs were analyzed to determine the degree of stem migration from its initial postoperative position. These parameters were compared to those of a cohort of 54 patients implanted with a monolithic