Abstract. Background. Oxidized zirconium (OxZr) has been introduced as an alternative bearing for femoral components in Total Knee Arthroplasty (TKA). It has a ceramic-like zirconium oxide outer layer with a low coefficient of friction. Early studies have found OxZr TKA to have a low incidence of early failure in young high demand patients. Currently no study has reported on the outcome of these implants beyond ten years. Objectives. The purpose of our study was to present an in-depth 15-year
Unicompartmental knee osteoarthritis can be treated with either Total Knee Arthroplasty (TKA) or Unicompartmental Knee Arthroplasty (UKA) and controversy remains as to which treatment is best. UKA has been reported to offer a variety of advantages, however many still see it as a temporary procedure with higher revision rates. We aimed to clarify the role of UKA and evaluate the long-term and revision outcomes. We retrospectively reviewed the pain, function and total Knee Society Score (KSS) for 602 UKA and 602 TKA in age and gender matched patients over ten years. The total pre-operative KSS scores were not significantly different between UKA and TKA (42.67 vs 40.54 P=0.021). KSS (pain) was significantly better in the TKA group (44.39 vs 41.38 P= 0.007) at one year and at five years post-operatively (45.33 vs 43.12 P=0.004). There was no statistically significant difference for KSS (total) in TKA and UKA during the study period. 16.3% of UKA and 20.1% of TKA had a documented complication. 79 UKA (13%) and 36 TKA (6%) required revision surgery. Despite the higher revision rate, pre-operative KSS (total) before revision was not significantly different between UKA and TKA (42.94 vs 42.43 P=0.84). Performance for UKAs was inferior to TKAs in Kaplan-Meier cumulative
Background: Publications concerning recurrent disc disease quote percentage recurrence without regard to the times of recurrence and the influence of longer follow-up. Objective: To assess the use of
Aims. The aim of this to study was to compare the previously unreported
long-term survival outcome of the Oxford medial unicompartmental
knee arthroplasty (UKA) performed by trainee surgeons and consultants. . Patients and Methods. We therefore identified a previously unreported cohort of 1084
knees in 947 patients who had a UKA inserted for anteromedial knee
arthritis by consultants and surgeons in training, at a tertiary
arthroplasty centre and performed
Arthroscopy of ankle is becoming a common procedure for the diagnosis and treatment of ankle pain. Little information exists regarding the long term prognosis following ankle arthroscopy, particularly in avoiding further major surgery. The purpose of this study is to evaluate the prognosis of arthroscopic ankle treatment, based on
Objective: The purpose of this study is to evaluate the prognosis of arthroscopic ankle treatment. Also we will formalise the relationship between the arthroscopic treatment and time for a further major ankle surgery. Patients and Methods: Consecutive Case Series study using prospectively gathered database. Between January 1997 to December 2000, Eighty consecutive patients (80 ankles) having ankle arthroscopy with the finding of Osteoarthritis (OA) or impingement were identified and their outcome at five years ascertained. Arthroscopic procedure involved pre operative skin markings. Ankle distraction is used. An anterior approach used with standard Anteromedial and antero-lateral portals. Treatment: debridement of osteochondral lesions, removal of loose bodies, curettage, drilling, synovec-tomy, and abrasion of the subchondral bone. All ankle joints had wash out. Results: Results were examined using Kaplan Meier
Introduction: Osteogenic Sarcoma is one of the most common malignant bone tumors in the younger population. The advances in chemotherapy in conjunction with surgery has improved the survival rates from less than 20% in 1970s to more than 70% in 1990s. Advanced imaging, better histopathological techniques, availability of bone banks and newer chemotherapeutic agents have made limb salvage surgery a viable option even in advanced stages of the disease. We reviewed the outcome and analysed the complications of patients with Osteogenic Sarcoma at our institution. Materials and methods: The objective of our study was to evaluate our experience with the treatment of osteogenic sarcoma and to do a
Aims: In this study, data from previously published
Objectives. To examine patient mortality, implant survivorship, and complication profiles of proximal femoral replacement (PFR) as compared to revision total hip arthroplasty (REV) or open reduction internal fixation (ORIF) in the treatment of acute periprosthetic fractures of the proximal femur. Methods. We performed a retrospective controlled chart review at our tertiary center from from 2000–2010, identifying 97 consecutive acute periprosthetic proximal femoral fractures. Patients were stratified into three treatment groups: PFR (n=21), REV (n=19), and ORIF (n=57). Primary outcome measures included death, implant failure, and reoperation. We also recorded patient demographics, medical comorbidities, fracture type, treatment duration, time to treatment, and complication profiles. Statistical analyis included competing risks survival, which allows independent
Introduction. Reverse hybrid total hip replacement (THR) offers significant theoretical benefits but is uncommonly used. Our primary objective was to evaluate implant survival with all cause revision and revision for aseptic loosening of either component as endpoints. Patients/Materials & Methods. Data was collected prospectively on 1, 088 (988 patients) consecutive reverse hybrid THRs. Mean patient age was 69.3 years (range, 21–94) and mean follow-up was 8.2 years (range, 5–11.3). No patients were lost to follow-up. Overall, 194 (17.8%) procedures were performed in patients under 60 years, 666 (61.1%) were performed in female patients and 349 (32.1%) were performed by a trainee. Acetabular components were ultra-high molecular weight polyethylene in 415 (38.1%) hips, highly cross-linked polyethylene in 669 (61.5%) hips and vitamin E stabilised polyethylene in 4 (0.4%) hips. Femoral stems were collared in 757 (69.7%) hips and collarless in 331 (30.3%) hips. Femoral head sizes were 28 mm in 957 (87.9%) hips and 32 mm in 131 (12.1%) hips.
Introduction: Unicompartmental osteoarticular defects of the knee are challenging due to demands of stability and function of this weight-bearing joint. Prostheses reconstruction often requires sacrificing the uninvolved compartment. Osteoarticular allograft reconstruction can restore the anatomy, and allows reattaching soft tissue structures such as meniscus and ligaments from the host. The purpose of this study was to perform a
Aims. The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. Methods. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for
Aims. Bacteriophages infect, replicate inside bacteria, and are released from the host through lysis. Here, we evaluate the effects of repetitive doses of the Staphylococcus aureus phage 191219 and gentamicin against haematogenous and early-stage biofilm implant-related infections in Galleria mellonella. Methods. For the haematogenous infection, G. mellonella larvae were implanted with a Kirschner wire (K-wire), infected with S. aureus, and subsequently phages and/or gentamicin were administered. For the early-stage biofilm implant infection, the K-wires were pre-incubated with S. aureus suspension before implantation. After 24 hours, the larvae received phages and/or gentamicin. In both models, the larvae also received daily doses of phages and/or gentamicin for up to five days. The effect was determined by
Introduction. In the early 2000s hip resurfacing became an established bone conserving hip arthroplasty option particularly for the fit and active patient cohort. The performance of second-generation metal-on-metal bearings had led to the reintroduction of hip resurfacing. The Birmingham Hip resurfacing (BHR) was introduced in 1997. This was followed by a number of different designs of the hip resurfacing. The Durom hip resurfacing was introduced in 2001. These two designs had different metallurgical properties, design parameters particularly clearance and different implantation techniques. Data from joint registries show that both prosthesis perform well. Objectives. Our objective was to perform a retrospective
Both mobile bearing and fixed bearing unicompartmental knee arthroplasty (UKA) have demonstrated clinical success. However, much debate persists about the superiority of a single design. Currently most clinical data is based on high volume centers data, however to reduce bias, we undertook a through review of retrospective national joint registries. In this study, we aim to investigate UKA implant utilization and survivorship between 2000 and 2018. Ten annual joint registry reports of various nations were reviewed. Due to the variable statistical methods of reporting implant use and survivorship we focused on three registries: Australia (AOANJRR), New Zealand (NZJR), United Kingdom (NJR) for uniformity. We evaluated UKA usage, survivorship, utilization and revision rates for each implant. Implant survivorship was reported in the registries and was compared within nations due to variation in statistical reporting.Introduction
Methods
Aims: Analyze the long-term survival of cementless meniscal bearing total knee arthroplasty (TKA). Methods: Two hundred and thirty-two consecutive cementless primary meniscal bearing Low Contact Stress TKA were performed on 203 patients in our institution from November 1988 to June 1996. The diagnosis was osteoarthritis in 192 knees (83%) and rheumatoid arthritis in 40 cases (17%). Mean age at surgery was 66.5 years (range:16–90). Cruciate retaining prosthesis was implanted in 81% and a cruciate sacrificing prosthesis in 19%. Twenty patients died and ten patients (4,3%) were lost to follow-up. The remaining 202 knees (87%) had an average follow-up of 116.7 months (range:70–165).
The purpose of this study was to establish the long-term clinical outcome of the Oxford Medial Unicompartmental Knee Arthroplasty (UKA). Methods: A continuous series of 420 patients underwent medial Oxford UKA. Indications were anteromedial osteoarthritis with full thickness lateral compartment cartilage, a functioning anterior cruciate ligament and correctable varus deformity.
Purpose: The purpose of this study was to report the mid-term survival results of Oxford UKAs in patients of 50 years of age or less, using (1) revision surgery and (2) Oxford Knee Scores (OKS) as outcome measures. Method: A literature review identified studies of Oxford mobile bearing UKAs containing individuals 1) 50 years old or less with 2) medial osteoarthritis and 3) 2 years or longer follow-up. Authors were approached to participate in a multi-centre
Introduction. We have carried out a 15 year