Advertisement for orthosearch.org.uk
Results 1 - 20 of 91
Results per page:

Aims. There are concerns regarding nail/medullary canal mismatch and initial stability after cephalomedullary nailing in unstable pertrochanteric fractures. This study aimed to investigate the effect of an additional anteroposterior blocking screw on fixation stability in unstable pertrochanteric fracture models with a nail/medullary canal mismatch after short cephalomedullary nail (CMN) fixation. Methods. Eight finite element models (FEMs), comprising four different femoral diameters, with and without blocking screws, were constructed, and unstable intertrochanteric fractures fixed with short CMNs were reproduced in all FEMs. Micromotions of distal shaft fragment related to proximal fragment, and stress concentrations at the nail construct were measured. Results. Micromotions in FEMs without a blocking screw significantly increased as nail/medullary canal mismatch increased, but were similar between FEMs with a blocking screw regardless of mismatch. Stress concentration at the nail construct was observed at the junction of the nail body and lag screw in all FEMs, and increased as nail/medullary canal mismatch increased, regardless of blocking screws. Mean stresses over regions of interest in FEMs with a blocking screw were much lower than regions of interest in those without. Mean stresses in FEMs with a blocking screw were lower than the yield strength, yet mean stresses in FEMs without blocking screws having 8 mm and 10 mm mismatch exceeded the yield strength. All mean stresses at distal locking screws were less than the yield strength. Conclusion. Using an additional anteroposterior blocking screw may be a simple and effective method to enhance fixation stability in unstable pertrochanteric fractures with a large nail/medullary canal mismatch due to osteoporosis. Cite this article: Bone Joint Res 2022;11(3):152–161


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 40 - 40
11 Apr 2023
Mahdi H Hardisty M Fullerton K Huang C Vachhani K Nam D Whyne C
Full Access

µCT images are commonly analysed to assess changes in bone density and architecture in preclinical murine models. Several platforms provide automated analysis of bone architecture parameters from volumetric regions of interest (ROI). However, segmentation of the regions of subchondral bone to create the volumetric ROIs remains a manual and time-consuming task. This study aimed to develop and evaluate automated pipelines for trabecular bone architecture analysis of mouse proximal tibia subchondral bone. A segmented dataset involving 62 knees (healthy and arthritic) from 10-week male C57BL/6 mice were used to train a U-Net type architecture, with µCT scans (downsampled) input that output segmentation and bone volume density (BV/TV) of the subchondral trabecular bone. Segmentations were upsampled and used in tandem with the original scans (10µ) as input for architecture analysis along with the thresholded trabecular bone. The analysis considered the manually and U-Net segmented ROIs using two available pipelines: the ITKBoneMorphometry library and CTan (SKYSCAN). The analyses included: bone volume (BV), total volume (TV), BV/TV, trabecular number (TbN), trabecular thickness (TbTh), trabecular separation (TbSp), and bone surface density (BSBV). There was good agreement for bone measures between the manual and U-Net pipelines utilizing ITK (R=0.88-0.98) and CTan (R=0.91-0.98). ITK and CTan showed good agreement for BV, TV, BV/TV, TbTh and BSBV (R=0.9-0.98). However, a limited agreement was seen between TbN (R=0.73) and TbSb (R=0.59) due to methodological differences in how spacing is evaluated. This U-Net/ITK pipeline seamlessly automated both segmentation and quantification of the proximal tibia subchondral bone. This automated pipeline allows the analysis of large volumes of data, and its open-source nature may enable the standardization of stereologic analysis of trabecular bone across different research groups


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 73 - 73
23 Jun 2023
Sheth N Bostrom M Winzenrieth R Humbert L Pearman L Caminis J Wang Y Boxberger J Krohn K
Full Access

To evaluate the effects of 6 and 18 months of abaloparatide (ABL) compared with placebo (PBO) on bone mineral density (BMD) in the acetabular regions of postmenopausal women with osteoporosis (OP). Acetabular bone loss, as may occur in OP, increases risk of acetabular fragility fractures. a. In total hip arthroplasty (THA), low acetabular BMD adversely affects primary stability, osseointegration, and migration of acetabular cups. c. ABL is an osteoanabolic agent for the treatment of men and postmenopausal women with OP at high risk for fracture. Effects of ABL on acetabular BMD are unknown. Hip DXA scans were obtained at baseline, 6, and 18 months from a random subgroup of postmenopausal women (aged 49–86 y) from the phase 3 ACTIVE trial randomized to either ABL 80 µg/d or PBO (n=250/group). Anatomical landmarks were identified in each DXA scan to virtually place a hemispherical shell model of an acetabular cup and define regions of interest corresponding to DeLee & Charnley zones 1 (R1), 2 (R2), and 3 (R3). BMD changes compared to baseline were calculated for each zone. Statistical P values were based on a repeated mixed measures model. BMD in all zones were similar at baseline in the ABL and PBO groups. BMD significantly increased in the ABL group at 6 and 18 months compared with PBO (all P<0.0001 vs PBO). BMD in the PBO group was relatively stable over time. ABL treatment resulted in rapid and progressive increases in BMD of all 3 acetabular zones. Increasing acetabular BMD has the potential to improve acetabular strength, which may reduce risk of acetabular fragility fractures. In bone health optimization prior to THA, increased acetabular BMD via ABL may provide better primary stability and longevity of acetabular cups in postmenopausal women with OP


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 24 - 24
17 Nov 2023
Alturkistani Z Amin A Hall A
Full Access

Abstract. Objective. The preparation of host degenerate cartilage for repair typically requires cutting and/or scraping to remove the damaged tissue. This can lead to mechanical injury and cartilage cell (chondrocytes) death, potentially limiting the integration of repair material. This study evaluated cell death at the site of cutting injury and determined whether raising the osmotic pressure (hyper-osmolarity) prior to injury could be chondroprotective. Methods. Ex vivo human femoral head cartilage was obtained from 13 patients (5 males and 8 females: 71.8 years old) with Ethical Permission and Patient consent. Cartilage wells were created using 3 or 5mm biopsy punches. Cell death at the wounded edge of the host cartilage and the edge of the extracted explants were assessed by quantifying the percentage of cell death (PCD) and measuring the width of the cell death zone at identified regions of interest (ROI) using the confocal laser scanning microscopy and image analysis software. To assess the chondroprotective effect of hyper-osmolarity, cartilage specimens were incubated in 340 or 600mOsm media, five minutes prior to injury to allow the chondrocytes to respond to the altered osmolarity. Wounded cartilage explants and cartilage wells were then cultured for a further 150 minutes following injury. Results. In 340mOsm media, the PCD around the 3mm cartilage wells was significantly less compared to the corresponding explants (20.05±10.24% vs 35.25±4.86%; P=0.0003). When using the 5mm biopsy punch, the PCD at the wound edges was significantly lower when compared to the 3mm cartilage wells (13.33±7.80% vs 20.05±10.24%; P=0.0121) at the same osmolarity. The width of the cell death zone for the well edges for both 3 and 5mm punches was significantly narrower when compared to their corresponding harvested cartilage explants in 340mOsm media (P<0.0001; P=0.0218, respectively). Exposing cartilage to raised osmolarity (600mOsm) prior to injury significantly reduced the PCD for cartilage wells produced by the 3mm biopsy punches (from 20.05±10.24% to 12.24±6.00%; P=0.0025). In addition, the zone of cell death was marginally reduced at the edges of the 5mm cartilage wells (19.25±15.78mm to 12.72±9.09mm; P=0.0499). Conclusions. The choice of biopsy punch and the osmolarity of the incubation medium prior to cartilage injury markedly affected the extent of chondrocyte death both at the edges of the cartilage wells and the explants. The smaller biopsy punch caused more chondrocyte death in the native cartilage wells compared to the larger punch, but this could be compensated for by the chondroprotective effect of raising the osmotic pressure. In general, there was less cell death at the wounded edges of the cartilage wells, compared to the explants. These results suggest that there is scope for further optimising the cutting implements used to create the cartilage wells and protecting chondrocytes by hyper-osmolarity in order to minimize cell death at cut edges and potentially enhance integration between cartilage repair material and host cartilage. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 57 - 57
1 Dec 2022
Champagne A McGuire A Shearer K Brien D Martineau PA Bardana DD
Full Access

Reconstruction of the anterior cruciate ligament (ACL) allows to restore stability of the knee, in order to facilitate the return to activity (RTA). Although it is understood that the tendon autograft undergoes a ligamentous transformation postoperatively, knowledge about longitudinal microstructural differences in tissue integrity between types of tendon autografts (ie, hamstring vs. patella) remains limited. Diffusion tensor imaging (DTI) has emerged as an objective biomarker to characterize the ligamentization process of the tendon autograft following surgical reconstruction. One major limitation to its use is the need for a pre-injury baseline MRI to compare recovery of the graft, and inform RTA. Here, we explore the relationship for DTI biomarkers (fractional anisotropy, FA) between knees bilaterally, in healthy participants, with the hypothesis that agreement within a patient's knees may support the use of the contralateral knee as a reference to monitor recovery of the tendon autograft, and inform RTA. Fifteen participants with no previous history of knee injuries were enrolled in this study (age, 26.7 +/− 4.4 years; M/F, 7/8). All images were acquired on a 3T Prisma Siemens scanner using a secured flexible 18-channel coil wrapped around the knee. Both knees were scanned. A 3D anatomical Double Echo Steady State (DESS) sequence was acquired on which regions of interest (ROI) were placed consistent with the footprints of the ACL (femur, posteromedial corner on medial aspect of lateral condyle; tibia, anteromedial to intercondylar eminence). Diffusion images were acquired using fat saturation based on optimized parameters in-house. All diffusion images were pre-processed using the FMRIB FSL toolbox. The footprint ROIs of the ACL were then used to reconstruct the ligament in each patient with fiber-based probabilistic tractography (FBPT), providing a semi-automated approach for segmentation. Average FA was computed for each subject, in both knees, and then correlated against one another using a Pearson correlation to assess the degree of similarity between the ACLs. A total of 30 datasets were collected for this study (1/knee/participant; N=15). The group averaged FA (+/− standard deviation) for the FBPT segmented ACLs were found to equal 0.1683 +/− 0.0235 (dominant leg) and 0.1666 +/− 0.0225 (non-dominant leg). When comparing both knees within subjects, reliable agreement was found for the FBPT-derived ACL with a linear correlation coefficient (rho) equal to 0.87 (P < 0 .001). We sought to assess the degree of concordance in FA between the knees of healthy participants with hopes to provide a method for using the contralateral “healthy” knee in the comparison of autograft-dependent longitudinal changes in microstructural integrity, following ACL reconstruction. Our results suggest that good agreement in anisotropy can be achieved between the non-dominant and dominant knees using DTI and the FBPT segmentation method. Contralateral anisotropy of the ACL, assuming no previous injuries, may be used as a quantitative reference biomarker for monitoring the recovery of the tendon autograft following surgical reconstruction, and gather further insight as to potential differences between chosen autografts. Clinically, this may also serve as an index to supplement decision-making with respect to RTA, and reduce rates of re-injuries


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 56 - 56
17 Nov 2023
Algarni M Amin A Hall A
Full Access

Abstract. Objectives. Osteoarthritis (OA) is a complex joint disorder characterised by the loss of extracellular matrix (ECM) leading to cartilage degeneration. Changes to cartilage cell (chondrocyte) behaviour occur including cell swelling, the development of fine cytoplasmic processes and cell clustering leading to changes in cell phenotype and development of focal areas of mechanically-weak fibrocartilaginous matrix. [1]. To study the sequence of events in more detail, we have investigated the changes to in situ chondrocytes within human cartilage which has been lightly scraped and then cultured with serum. Methods. Human femoral heads were obtained with Ethical permission and consent from four female patients (mean age 74 yrs) undergoing hip arthroplasty following femoral neck fracture. Osteochondral explants of macroscopically-normal cartilage were cultured as a non-scraped control, or scraped gently six times with a scalpel blade and both maintained in culture for up to 2wks in Dulbecco's Modified Eagle's Medium (DMEM) with 25% human serum (HS). Explants were then labelled with CMFDA (5-chloromethylfluorescein-diacetate) and PI (propidium iodide) (10μM each) to identify the morphology of living or dead chondrocytes respectively. Explants were imaged using confocal microscopy and in situ chondrocyte morphology, volume and clustering assessed quantitatively within standardised regions of interest (ROI) using Imaris. ®. imaging software. Results. Within 2wks of culture with HS, chondrocyte volume increased significantly from 412±9.3µm. 3. (unscraped) at day 0 to 724±16.6 µm. 3. (scraped) [N(n) = 4(380)] (P=0.0002). Chondrocyte clustering was a prominent feature of HS culture as the percentage of clusters in the cell population increased with scraping from 4.8±1.4% to 14.9±3.9% [N(n) = 4(999)] at week 2 (P=0.0116). In addition, the % of the chondrocyte population within clusters increased from approximately 38% to 60%, and the number of cells per cluster increased significantly from 3.2±0.08 to 4±0.22 (P=0.031). The development of abnormal ‘fibroblastic-like’ chondrocyte morphology demonstrating long (>5µm) cytoplasmic processes also occurred, however the time course of this was more variable. For some samples, clustering occurred before abnormal morphology, but for others the opposite occurred. Typically, by the second week, 17±2.64% of the cell population had processes and this increased to 22±4.02% [N(n) = 4(759)] with scraping. Conclusions. Scraping the cartilage will remove surface constituents including lubricants (e.g. lubricin, hyaluronic acid, phospholipids), extracellular matrix constituents (collagen, proteoglycans – potentially the ‘lamina splendens’) and cells (chondrocytes and mesenchymal stromal cells (MSCs)). Although we do not know which of these component(s) is important, the effect is to dramatically increase the permeation of serum factors into the cartilage matrix and signal the development of cytoplasmic processes, cell clustering and swelling. It is notable that these cellular changes are similar to those occurring in early OA. [1]. This raises the interesting possibility that scraped cartilage cultured with human serum recapitulates some of the changes to in situ chondrocytes during early stages of cartilage degeneration and as such, could be a useful model for following the deleterious changes to matrix metabolism. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 50 - 50
1 Feb 2021
Sanchez E Schilling C Grupp T Giurea A Verdonschot N Janssen D
Full Access

Introduction. Cementless total knee arthroplasty (TKA) implants use an interference fit to achieve fixation, which depends on the difference between the inner dimensions of the implant and outer dimensions of the bone. However, the most optimal interference fit is still unclear. A higher interference fit could lead to a superior fixation, but it could also cause bone abrasion and permanent deformation during implantation. Therefore, this study aims to investigate the effect of increasing the interference fit from 350 µm to 700 µm on the primary stability of cementless tibial implants by measuring micromotions and gaps at the bone-implant interface when subjected to two loading conditions. Methods. Two cementless e.motion® tibial components (Total Knee System, B. Braun) with different interference fit and surface coating were implanted in six pairs of relatively young human cadaver tibias (47–60 years). The Orthoload peak loads of gait (1960N) and squat (1935N) were applied to the specimens with a custom made load applicator (Figure 1A). The micromotions (shear displacement) and opening/closing gaps (normal displacement) were measured with Digital Image Correlation (DIC) in 6 different regions of interest (ROIs - Figure 1B). Two General Linear Mixed Models (GLMMs) were created with micromotions and interfacial gaps as dependent variables, bone quality, loading conditions, ROIs, and interference fit implants as independent variables, and the cadaver specimens as subject variables. Results. No significant difference was found for the micromotions between the two interference fit implants (gait p=0.755, squat p=0.232), nor for interfacial gaps (gait p=0.474, squat p=0.269). In contrast, significant differences were found for the ROIs in the two dependent variables (p < 0.001). The micromotions in the anterior ROIs (AM and AL) showed fewer micromotions for the low interference fit implant (Figure 2). More closing gaps (negative values) were seen for all ROIs (Figure 3), except in AM ROI during squat, which showed opening gaps (positive values). The posterior ROIs (PM and PL) showed more closing than seen in the anterior ROIs (AM and AL) for both loading configurations. Discussion. The results presented here demonstrate that increasing the interference fit from 350 µm to 700 µm does not affect the micromotions at the implant-bone interface of tibial TKA. While micromotions values were all below the threshold for bone ingrowth (40 µm), closing gaps were quite substantial (∼−150 µm). Since cementless e.motion® TKA components with an interference fit of 350 µm had shown a survival rate of 96.2% after 8.3 years postoperatively, interfacial gaps can be expected to be within a threshold value that can guarantee good primary stability. Moreover, increasing the interference fit to 700 µm can be considered a good range for an interference fit. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 2 - 2
1 Feb 2021
Pizzamiglio C Fattori A Rovere F Poon P Pressacco M
Full Access

Background. Stemless prostheses are recognized to be an effective solution for anatomic total shoulder arthroplasty (TSA) while providing bone preservation and shortest operating time. Reverse shoulder arthroplasty (RSA) with stemless has not showed the same effectiveness, as clinical and biomechanical performances strongly depend on the design. The main concern is related to stability and bone response due to the changed biomechanical conditions; few studies have analyzed these effects in anatomic designs through Finite Element Analysis (FEA), however there is currently no study analyzing the reverse configuration. Additionally, most of the studies do not consider the effect of changing the neck-shaft angle (NSA) resection of the humerus nor the proper assignment of spatial bone properties to the bone models used in the simulations. The aim of this FEA study is to analyze bone response and primary stability of the SMR Stemless prosthesis in reverse with two different NSA cuts and two different reverse angled liners, in bone models with properties assigned using a quantitative computed tomography (QCT) methodology. Methods. Sixteen fresh-frozen cadaveric humeri were modelled using the QCT-based finite element methodology. The humeri were CT-scanned with a hydroxyapatite phantom to allow spatial bone properties assignment [Fig. 1]. Two implanted SMR stemless reverse configurations were considered for each humerus: a 150°-NSA cut with a 0° liner and a 135°-NSA cut with a 7° sloped liner [Fig. 2]. A 105° abduction loading condition was simulated on both the implanted reverse models and the intact (anatomic) humerus; load components were derived from previous dynamic biomechanical simulations on RSA implants for the implanted stemless models and from the OrthoLoad database for the intact humeri. The postoperative bone volume expected to resorb or remodel [Fig. 3a] in the implanted humeri were compared with their intact models in sixteen metaphyseal regions of interest (four 5-mm thick layers parallel to the resection and four anatomical quadrants) by means of a three-way repeated measures ANOVA followed by post hoc tests with Bonferroni correction. In order to evaluate primary stability, micromotions at the bone-Trabecular Titanium interface [Fig. 3b] were compared between the two configurations using a Wilcoxon matched-pairs signed-rank test. The significance level α was set to 0.05. Results. With the exception of the most proximal layer (0.0 – 5.0 mm), the 150°-NSA configuration showed overall a statistically significant lower bone volume expected to resorb (p = 0.011). In terms of bone remodelling, the 150°-NSA configuration had again a better response, but fewer statistically significant differences were found. Regarding micromotions, there was a median decrease (Mdn = 3.2 μm) for the 135°-NSA configuration (Mdn = 40.3 μm) with respect to the 150°-NSA configuration (Mdn = 43.5 μm) but this difference was non-significant (p = 0.464). Conclusions. For the analyzed SMR Stemless configurations, these results suggest a reduction in the risk of bone resorption when a 0° liner is implanted with the humerus cut at 150°. The used QCT-based methodology will allow further investigation, as this study was limited to one single design and load case. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 1 - 1
1 Mar 2020
Keenan O Holland G Maempel J Keating J Scott C
Full Access

Though knee osteoarthritis (OA) is diagnosed and monitored radiographically, full thickness cartilage loss (FTCL) has rarely been correlated with radiographic classification. This study aims to analyse which classification system correlates best with FTCL and assessing their reliability. Prospective study of 300 consecutive patients undergoing total knee arthroplasty (TKA) for OA. Two blinded examiners independently graded preoperative radiographs using 5 systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlback. Interobserver agreement was assessed using the intraclass correlation coefficient. Intraoperatively, anterior cruciate ligament (ACL) status and FTCL in 16 regions of interest were recorded. Radiographic classification and FTCL were correlated using the Spearman correlation coefficient. On average, each knee had 6.8±3.1 regions of FTCL, most common medially. The commonest patterns of FTCL were medial with patellofemoral (48%) and tricompartmental (30%). ACL status was associated with pattern of FTCL (p=0.02). All classification systems demonstrated moderate ICC, but this was highest for IKDC: whole knee 0.68 (95%CI 0.60–0.74); medial compartment 0.84 (0.80–0.87); and lateral compartment 0.79 (0.73–0.83). Correlation with FTCL was strongest for Ahlback (Spearman rho 0.27–0.39) and KL (0.30–0.33), though all systems demonstrated medium correlation. The Ahlback was the most discriminating in severe OA. Osteophyte presence in the medial compartment had high positive predictive value for FTCL, but not in the lateral compartment. The Ahlback and KL systems had the highest correlation with confirmed cartilage loss. However, the IKDC system displayed best interobserver reliability, with favourable correlation with FTCL in medial and lateral compartments, though less discriminating in severe disease


Bone & Joint Research
Vol. 5, Issue 7 | Pages 294 - 300
1 Jul 2016
Nishioka H Nakamura E Hirose J Okamoto N Yamabe S Mizuta H

Objectives. The purpose of this study was to clarify the appearance of the reparative tissue on the articular surface and to analyse the properties of the reparative tissue after hemicallotasis osteotomy (HCO) using MRI T1ρ and T2 mapping. Methods. Coronal T1ρ and T2 mapping and three-dimensional gradient-echo images were obtained from 20 subjects with medial knee osteoarthritis. We set the regions of interest (ROIs) on the full-thickness cartilage of the medial femoral condyle (MFC) and medial tibial plateau (MTP) of the knee and measured the cartilage thickness (mm) and T1ρ and T2 relaxation times (ms). Statistical analysis of time-dependent changes in the cartilage thickness and the T1ρ and T2 relaxation times was performed using one-way analysis of variance, and Scheffe’s test was employed for post hoc multiple comparison. Results. The cartilage-like repair tissue appeared on the cartilage surface of the medial compartment post-operatively, and the cartilage thickness showed a significant increase between the pre-operative and one-year post-operative time points (MFC; p = 0.003, MTP; p < 0.001). The T1ρ values of the cartilage-like repair tissue showed no difference over time, however, the T2 values showed a significant decrease between the pre-operative and one-year post-operative time points (MFC; p = 0.004, MTP; p = 0.040). Conclusion. This study clarified that the fibrocartilage-like repair tissue appeared on the articular surface of the medial compartment after HCO as evidenced by MRI T1ρ and T2 mapping. Cite this article: H. Nishioka, E. Nakamura, J. Hirose, N. Okamoto, S. Yamabe, H. Mizuta. MRI T1ρ and T2 mapping for the assessment of articular cartilage changes in patients with medial knee osteoarthritis after hemicallotasis osteotomy. Bone Joint Res 2016;5:294–300. DOI: 10.1302/2046-3758.57.BJR-2016-0057.R1


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 15 - 15
1 Aug 2020
Ehrlich J Bryant T Rainbow M Bicknell R
Full Access

The purpose of this study is to quantify the distribution of bone density in the scapulae of patients undergoing reverse shoulder arthroplasty (RSA) to guide optimal screw placement. To achieve this aim, we compared bone density in regions around the glenoid that are targeted for screw placement, as well as bone density variations medial to lateral within the glenoid. Specimen included twelve scapula in 12 patients with a mean age of 74 years (standard deviation = 9.2 years). Each scapula underwent a computed tomography (CT) scan with a Lightspeed+ XCR 16-Slice CT scanner (General Electric, Milwaukee, USA). Three-dimensional (three-D) surface mesh models and masks of the scapulae containing three-D voxel locations along with the relative Hounsfield Units (HU) were created. Regions of interest (ROI) were selected based on their potential glenoid baseplate screw positioning in RSA surgery. These included the base of coracoid inferior and lateral to the suprascapular notch, an anterior and posterior portion of the scapular spine, and an anterosuperior and inferior portion of the lateral border. Five additional regions resembling a clock face, on the glenoid articular surface were then selected to analyze medial to lateral variations in bone density including twelve, three, six, and nine-o'clock positions as well as a central region. Analysis of Variance (ANOVA) tests were used to examine statistical differences in bone density between each region of interest (p < 0 .05). For the regional evaluation, the coracoid lateral to the suprascapular notch was significantly less dense than the inferior portion of the lateral border (mean difference = 85.6 HU, p=0.03), anterosuperior portion of the lateral border (mean difference = 82.7 HU, p=0.04), posterior spine (mean difference = 97.6 HU, p=0.007), and anterior spine (mean difference = 99.3 HU, p=0.006). For the medial to lateral evaluation, preliminary findings indicate a “U” pattern with the densest regions of bone in the glenoid most medially and most laterally with a region of less dense bone in-between. The results from this study utilizing clinical patient CT scans, showed similar results to those found in our previous cadaveric study where the coracoid region was significantly less dense than regions around the lateral scapular border and scapular spine. We also have found for medial to lateral bone density, a “U” distribution with the densest regions of bone most medially and most laterally in the glenoid, with a region of less dense bone between most medial and most lateral. Clinical applications for our results include a carefully planned trajectory when placing screws in the scapula, potentially avoiding the base of coracoid. Additionally, surgeons may choose variable screw lengths depending on the region of bone and its variation of density medial to lateral, and that screws that pass beyond the most lateral (subchondral) bone, will only achieve further purchase if they enter the denser bone more medially. We suspect that if surgeons strategically aim screw placement for the regions of higher bone density, they may be able to decrease micromotion in baseplate fixation and increase the longevity of RSA


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 258 - 258
1 May 2006
Kamath S Shaari E McGill P Campbell AC
Full Access

Few studies suggest that the use of a cemented stem reduces proximal stresses and may result in proximal bone resorption. Aim of our study: Does bone cement affect peri prosthetic bone density? The study was approved by the local ethics committee. Patient and methods: 30 patients were included in each group based on power analysis. All 60 patients had the same type of knee replacement (Rotaglide rotating platform). Both groups, cemented and uncemented respectively were matched for the variables like mean age (67.2 & 67.33 years), gender (13: 17 males: females), body mass index (30.95, 29.90), average time following surgery (4 and 3.25 years), activity level (UCLA scoring: 6 & 4) and mean T score (osteoporosis index: −0.51 & −0.62). Periprosthetic bone density was measured in five regions of interest in the distal femur and five regions of interest in the proximal tibia. This was performed with Prodigy scanner (Lunar) using ‘orthopedic’ software to eliminate metal related artifacts. The same area was measured on the opposite unoperated knee. The values thus obtained were compared between the cemented and uncemented groups. Results: There was no statistically significant difference in bone density around proximal tibia, patella and bone density proximal to femoral flange. However, there was some difference between the groups for bone density behind the flange of the femoral component measured in the lateral view, although not strictly significant at the 5% level. In this region of interest, the bone density in the cemented group appears to be less than in the uncemented group (p=0.059). Conclusion: Use of bone cement do not seem to alter the peri prosthetic bone density contrary to suggestions in a few other studies. While reduction in periprosthetic bone density is noted in both groups, use of bone cement did not affect the results significantly


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 46 - 46
1 Mar 2008
Maurer J Ronsky J Loitz-Ramage B Andersen M Zernicke R Harder J
Full Access

The relations among tissue quality, socket discomfort, gait characteristics, and socket pressures are not well established for the unilateral below-knee amputee population. These relations were evaluated for six amputees at seventeen regions of interest on the residual limb. Pressure sensors were placed directly on the residual limb. Peak dynamic socket pressures were not directly related to peak joint moments. However, increases in ground reaction forces (GRFs) related to increases in socket pressures. The relations among tissue quality, socket discomfort, gait characteristics, and socket pressures are not well established for the unilateral below-knee amputee population. The purpose of this study was to evaluate these relations for six amputees. A thorough understanding of pressure distribution between the residual limb and prosthetic socket is critical to socket design and limb health. The subjects ranged in age from thirty to seventy-two years of age. The inclusion criteria were male, unilateral transtibial amputation, ability to ambulate independently, non-diabetic, no debilitating health conditions, non-recent amputee. Tissue sensation and socket discomfort were evaluated at seventeen regions of interest on the residual limb. Tissue sensation was assessed using Semmes-Weinstein monofilaments to test light touch/deep pressure sensation, tuning fork to test vibration sensation, and pinprick to test pain sensation. Socket discomfort was assessed using 10 cm Visual Analogue Scale. Gait characteristics were recorded during walking using a Motion Analysis System. Socket pressure measurements were made using F-socket pressure sensors in conjunction with I-Scan software program. Pressure sensors were placed directly on residual limb. Gait characteristics and socket pressures were compared across three different testing days. The site-specific tissue sensitivity scores did not correlate with the socket discomfort scores. In addition, site-specific discomfort scores did not correlate with peak socket pressures recorded at subject’s normal walking speed. Significant day-to-day pressure differences were found at four of the seventeen areas of interest. Peak dynamic socket pressures were not directly related to peak joint moments. Two subjects demonstrated direct relations between ground reaction forces (GRFs) and socket pressure on the different test days. Funding: NSERC, Workers’ Compensation Board (Alberta), University of Calgary


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 16 - 16
1 Nov 2018
Higashihira S Kobayashi N Inaba Y Oishi T Choe H Ike H Kobayashi D Watanabe S Saito T
Full Access

In this study, we evaluated the labrum tear using radial sequence 3D Multiple Echo Recombined Gradient Echo (MERGE) MRI without arthrography based on modified Czerny's classification, comparing with actual arthroscopic findings. A total of 61 hips including 27 hips of femoroacetabular impingement (FAI), 19 hips of borderline development dysplasia of the hip (BDDH) and 15 hips of early stage osteoarthritis (OA) were enrolled this retrospective study. MRI findings evaluated in each three regions of interest; anterior region, anterolateral region, and lateral region. The cases with severe degeneration that is not concordant with any original Czerny's classification is defined as stage4. We compared MRI findings with arthroscopic findings and calculated the sensitivity, specificity, and likelihood ratio in terms of the existence of labrum tear. MRI findings revealed labrum tear more frequently in anterolateral than lateral (p<0.001). Especially in FAI group, labrum tear was more frequently observed by MRI in anterolateral than lateral (p=0.006). In comparison with MRI findings and arthroscopic findings, the sensitivity was 97%, specificity was 79% and likelihood ratio was 4.59 as average of all regions in terms of the existence of labrum tear. In each region, sensitivity and specificity was 97% and 50% in anterior, 97% and 100% specificity in anterolateral, 94% and 81% in lateral, respectively. Thus, MERGE MRI revealed excellent sensitivity and specificity for diagnosis of labrum tear, especially in anterolateral region. The cases with severely degenerated labrum were classified as newly defined stage 4, which was recognized frequently in OA cases


Bone & Joint Research
Vol. 7, Issue 7 | Pages 457 - 467
1 Jul 2018
Smith IDM Milto KM Doherty CJ Amyes SGB Simpson AHRW Hall AC

Objectives. Staphylococcus aureus (S. aureus) is the most commonly implicated organism in septic arthritis, a condition that may be highly destructive to articular cartilage. Previous studies investigating laboratory and clinical strains of S. aureus have demonstrated that potent toxins induced significant chondrocyte death, although the precise toxin or toxins that were involved was unknown. In this study, we used isogenic S. aureus mutants to assess the influence of alpha (Hla)-, beta (Hlb)-, and gamma (Hlg)-haemolysins, toxins considered important for the destruction of host tissue, on in situ bovine chondrocyte viability. Methods. Bovine cartilage explants were cultured with isogenic S. aureus mutants and/or their culture supernatants. Chondrocyte viability was then assessed within defined regions of interest in the axial and coronal plane following live- and dead-cell imaging using the fluorescent probes 5-chloromethylfluorescein diacetate and propidium iodide, respectively, and confocal laser-scanning microscopy. Results. Hla-producing mutants caused substantial chondrocyte death compared with the toxin-deficient control (Hla-Hlb-Hlg-), whilst mutants producing Hlb and Hlg in the absence of Hla induced minimal chondrocyte death. Coronal studies established that Hla-induced chondrocyte death started in the superficial zone of cartilage and spread to deeper layers, whereas Hlb and Hlg toxins were without significant effect. Conclusion. This study identified Hla as a highly potent S. aureus toxin that caused rapid chondrocyte death in bovine cartilage, with other toxins or metabolic products produced by the bacteria playing a minor role. The identification of Hla in mediating chondrocyte death may assist in the development of therapeutic strategies aimed at reducing the extent of cartilage damage during and after an episode of septic arthritis. Cite this article: I. D. M. Smith, K. M. Milto, C. J. Doherty, S. G. B. Amyes, A. H. R. W. Simpson, A. C. Hall. A potential key role for alpha-haemolysin of Staphylococcus aureus in mediating chondrocyte death in septic arthritis. Bone Joint Res 2018;7:457–467. DOI: 10.1302/2046-3758.77.BJR-2017-0165.R1


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 411 - 411
1 Oct 2006
Shetty N Hamer A Stockley I Eastell R Wilkinson J
Full Access

Dual energy X-ray absorptiometry (DXA) is a precise tool for measuring bone mineral density (BMD) around total joint prostheses. The Hologic ‘metal-removal hip’ analysis package (Hologic Inc, Waltham, Massachusetts) is a DOS-based analysis platform that has been previously validated for measurement of pelvic and proximal BMD after total hip arthroplasty (THA). This software has undergone a change in the operating platform to a Windows-based system that has also incorporated changes to DXA image manipulation on-screen. These changes may affect the magnitude of random error (precision) and systematic error (bias) when compared with measurements made using the previously validated DOS-based system. These factors could influence interpretation of longitudinal studies commenced using the DOS system and later completed using the Windows system. The aims of this study were to compare the precision and bias of pelvic and femoral periprosthetic BMD measurements made using the Windows versus the DOS analysis platform of the Hologic ‘metal-removal hip’ software. A total of 29 subjects (17 men and 12 women) with a mean age of 51years (SD±10), who had undergone hybrid THA using a cemented stem and uncemented cup. Subjects underwent duplicate DXA scans of the hemipelvis and proximal femur taken on the same day after a period for repositioning.. Scans were obtained with the patient lying supine in the scanner with the legs in extension and the foot in a neutral position. Scans were carried out using the same Hologic QDR 4500-A fan-beam densitometer in ‘metal-removal hip’ scanning mode. The DXA scan acquisitions were analysed using both the DOS and the Windows versions of the analysis software. The same observer made all analyses (NRS). Pelvic scans were analysed using a four region of interest model and femoral scans were analysed using a seven region of interest model. Precision was expressed as coefficient of variation (CV%) and compared between methods using the F-test. Systematic bias was examined using the Bland and Altman method and paired t-test. The CV% for the pelvic regions of interest (n=4) varied from 3.92 to 8.54 and from 2.36 to 5.96 for the Windows and DOS systems, respectively. The CV% for the net pelvic region was 3.04 and 2.36 for Windows versus DOS, respectively (F- test, p> 0.05). The CV% for the femoral regions of interest (n=7) varied from 1.58 to 4.14 and from 1.84 to 4.65 for the Windows and DOS systems, respectively. The CV% for the net femoral region was 1.75 and 1.51 for Windows versus DOS, respectively (F- test, p> 0.05). Absolute BMD values for the net pelvic region were similar (Bland-Altman, Windows minus DOS value mean = -1.0%, 95% CI −7.5 to 5.6; t-test p.0.05). Absolute BMD values for the net femoral region were also similar (Bland-Altman, Windows minus DOS value mean = 1.3%, 95% CI −8.3 to 10.8; t-test p.0.05). In summary precision of the measurements using the 2 operating systems was similar and there was no systematic bias between methods. These data suggest that scans analysed using each platform may be used interchangeably within the same study subjects, without the need of a calibration correction


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 125 - 125
1 Apr 2019
Sanchez E Schilling C Grupp TM Verdonschot N Janssen D
Full Access

Introduction. Although cementless press-fit femoral total knee arthroplasty (TKA) components are routinely used in clinical practice, the effect of the interference fit on primary stability is still not well understood. Intuitively, one would expect that a thicker coating and a higher surface roughness lead to a superior fixation. However, during implant insertion, a thicker coating can introduce more damage to the underlying bone, which could adversely influence the primary fixation. Therefore, in the current study, the effect of coating thickness and roughness on primary stability was investigated by measuring the micromotions at the bone-implant interface with experimental testing. Methods. A previous experimental set-up was used to test 6 pairs of human cadaveric femurs (47–60 years, 5 females) implanted with two femoral component designs with either the standard e.motion (Total Knee System, B. Braun, Germany) interference fit of 350 µm (right femurs) or a novel, thicker interference fit of 700 µm (left femurs). The specimens were placed in a MTS machine (Figure 1) and subjected to the peak loads of normal gait (1960N) and squat (1935N), based on the Orthoload dataset for Average 75. Varus/valgus moments were incorporated by applying the loads at an offset relative to the center of the implants, leading to a physiological mediolateral load distribution. Under these loads, micromotions at the implant-bone interface were measured using Digital Image Correlation (DIC) at different regions of interest (ROIs – Figure 1). In addition, DIC was used to measure opening and closing of the implant-bone interface in the same ROIs. Results. After comparing the micromotions and opening of the two implant designs, we found no significant differences between the standard and novel coating. Loading was a significant factor for both opening (P<0.0001) and micromotions (P=0.019), where the squat produced higher micromotions than gait. Opening was seen anteriorly (MA, LA), and was higher during squat. Closing was noticed distally (MD, LD), particularly during gait (Figure 2). During gait (Figure 3), the highest micromotions were found in the posterior condyles (CM, MP), followed by the medial anterior region (MA). For squat, the largest micromotions were in the anterior flange (ANT), followed by the distal regions (LD, MD). Discussion. In the current study, the primary stability of the same implant with two different coating thicknesses was evaluated. The results demonstrate that increasing the coating thickness does not automatically influence the primary stability of a femoral TKA component. This is likely due to abrasion and damage of the underlying trabecular during implant insertion, which also was observed in previous experiments. The exact relation between coating thickness or interference fit and primary implant stability still remains subject to debate. Obviously, the primary implant stability is compromised when the interference fit is too low. However, the current results suggest that there is a threshold beyond which further improvement of the fixation is not possible. The exact magnitude of this threshold is unknown, and may depend on coating characteristics and bone quality, and requires further evaluation, possibly utilizing a hybrid approach of experimental and computational techniques


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 10 - 10
1 Aug 2018
Hooper G Gilchrist N Maxwell R Frampton C
Full Access

Stress shielding has been a well-recognised problem with uncemented femoral components resulting in proximal bone loss and dysfunction, but less attention has been paid to the preservation of acetabular bone stock. Uncemented acetabular components often demonstrate reduced bone density on plain radiographs in the mid-portion of the cup (zone 2), which may be due to the rigidity of the outer shell. This study compares the change in bone density around three different cups with varying moduli of elasticity at a minimum of 2 years. Our hypothesis was that less rigid cups would be associated with improved bone density and less stress shielding. This prospective randomised controlled trial compared the bone mineral content (BMC) adjacent to three different cups with marked differences in stiffness. Cup A was an all titanium shell, cup B was a titanium coated all polyethylene implant and cup C was a tantalum backed shell. All articulations used a 32mm ceramic femoral head. Cup B used polyethylene modified by treatment with vitamin E whereas cups A and C used a liner made of irradiated cross linked polyethylene. Five regions of interest (ROI) were established adjacent to the cup, regions 2, 3 and 4 where similar to the DeLee and Charnley regions 1, 2 and 3. Bone density was measured using IDXA preoperatively, postoperatively, 6 months, 1 and 2 years and compared for each ROI and implant. Precision measurements showed significant reliability. All areas showed a reduction in BMC following insertion of the acetabular cup. Bone loss was less in ROI 1 and 4 in the area of rim fit for all cups and the maximal bone loss was seen in ROI 2 and 3 at the dome of the cup. The more elastic cup (Cup B) produced the least bone loss in this area (p<0.05). Cup C produced the largest bone loss at ROI 2 (40%) which continued increasing at 2 years. Cup stiffness is related to bone loss adjacent to the acetabulum, presumably due to a similar process of stress shielding as seen in the femur. All cups produced similar changes at the periphery of the cup but the more elastic cup retained bone density beneath the cup which continued past 2 years. This improvement in bone quality is likely to be associated with better acetabular bone stock into the future and more reliable long term cup fixation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 22 - 22
1 Apr 2019
Massari L Bistolfi A Grillo PP Causero A
Full Access

Introduction. Trabecular Titanium is a biomaterial characterized by a regular three-dimensional hexagonal cell structure imitating trabecular bone morphology. Components are built via Electron Beam Melting technology in aone- step additive manufacturing process. This biomaterial combines the proven mechanical properties of Titanium with the elastic modulus provided by its cellular solid structure (Regis 2015 MRS Bulletin). Several in vitro studies reported promising outcomes on its osteoinductive and osteoconductive properties: Trabecular Titanium showed to significantly affect osteoblast attachment and proliferation while inhibiting osteoclastogenesis (Gastaldi 2010 J Biomed Mater Res A, Sollazzo 2011 ISRN Mater Sci); human adipose stem cells were able to adhere, proliferate and differentiate into an osteoblast-like phenotype in absence of osteogenic factors (Benazzo 2014 J Biomed Mater Res A). Furthermore, in vivo histological and histomorphometric analysis in a sheep model indicated that it provided bone in-growth in cancellous (+68%) and cortical bone (+87%) (Devine 2012 JBJS). A multicentre prospective study was performed to assess mid-term outcomes of acetabular cups in Trabecular Titanium after Total Hip Arthroplasty (THA). Methods. 89 patients (91 hips) underwent primary cementless THA. There were 46 (52%) men and 43 (48%) women, with a median (IQR) age and BMI of 67 (57–70) years and 26 (24–29) kg/m2, respectively. Diagnosis was mostly primary osteoarthritis in 80 (88%) cases. Radiographic and clinical evaluations (Harris Hip Score [HHS], SF-36) were performed preoperatively and at 7 days, 3, 6, 12, 24 and 60 months. Bone Mineral Density (BMD) was determined by dual-emission X-ray absorptiometry (DEXA) according to DeLee &Charnley 3 Regions of Interest (ROI) postoperatively at the same time-points using as baseline the measureat 1 week. Statistical analysis was carried out using Wilcoxon test. Results. Median (IQR) HHS and SF-36 improved significantly from 48 (39–61) and 49 (37–62) preoperatively to 99 (96–100) and 76 (60–85) at 60 mo. (p≤0.0001). Radiographic analysis showed evident signs of bone remodelling and biological fixation, with presence of superolateral and inferomedial bone buttress, and radial trabeculae in ROI I/II. All cups resulted radiographically stable without any radiolucent lines. The macro-porous structure of this biomaterial generates a high coefficient of friction (Marin 2012 Hip Int), promoting a firm mechanical interlocking at the implant-bone interface which could be already observed in the operating room. BMD initially declined from baseline at 7 days to 6 months. Then, BMD slightly increased or stabilized in all ROIs up to 24 months, while showing evidence of partial decline over time with increasing patient' age at 60 months, although without any clinical significance in terms of patients health status or implant stability. Statistical significant correlations in terms of bone remodeling were observed between groups of patients on the basis of gender and age (p≤0.05). No revision or implant failure was reported. Conclusions. All patients reported significant improvements in quality of life, pain relief and functional recovery. Radiographic evaluation confirmed good implant stability at 60 months. These outcomes corroborate the evidence reported on these cups by orthopaedic registries and literature (Perticarini 2015 BMC Musculoskelet Disord; Bistolfi 2014 Min Ortop)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 19 - 19
1 Oct 2016
Griffin M Annan J Hamilton D Simpson A
Full Access

3D imaging is commonly employed in the surgical planning and management of bony deformity. The advent of desktop 3D printing now allows rapid in-house production of specific anatomical models to facilitate surgical planning. The aim of this pilot study was to evaluate the feasibility of creating 3D printed models in a university hospital setting. For requested cases of interest, CT DICOM images on the local NHS Picture Archive System were anonymised and transferred. Images were then segmented into 3D models of the bones, cleaned to remove artefacts, and orientated for printing with preservation of the regions of interest. The models were printed in polylactic acid (PLA), a biodegradable thermoplastic, on the CubeX Duo 3D printer. PLA models were produced for 4 clinical cases; a complex forearm deformity as a result of malunited childhood fracture, a pelvic discontinuity with severe acetabular deficiency following explantation of an infected total hip replacement, a chronically dislocated radial head causing complex elbow deformity as a result of a severe skeletal dysplasia, and a preoperative model of a deficient proximal tibia as a result of a severe tibia fracture. The models materially influenced clinical decision making, surgical intervention planning and required equipment. In the case of forearm an articulating model was constructed allowing the site of impingement between radius and ulnar to be identified, an osteotomy was practiced on multiple models allowing elimination of the block to supination. This has not previously been described in literature. The acetabulum model allowed pre-contouring of a posterior column plate which was then sterilised and eliminated a time consuming intraoperative step. While once specialist and expensive, in house 3D printing is now economically viable and a helpful tool in the management of complex patients