Aims. This study was designed to develop a model for predicting bone mineral density (BMD) loss of the femur after total hip arthroplasty (THA) using artificial intelligence (AI), and to identify factors that influence the prediction. Additionally, we virtually examined the efficacy of administration of bisphosphonate for cases with severe BMD loss based on the predictive model. Methods. The study included 538 joints that underwent
Aims. Golf is a popular pursuit among those requiring total hip arthroplasty (THA). The aim of this study was to determine if participating in golf is associated with greater functional outcomes, satisfaction, or improvement in quality of life (QoL) compared to non-golfers. Methods. All patients undergoing
Aims. The aim of this study was to estimate the clinical and economic burden of dislocation following
In
Arthrofibrosis is a relatively frequent complication after total knee arthroplasty. Although stiffness after total hip arthroplasty (THA), because of formation of heterotopic ossification or other causes, is not uncommon, to the authors’ best knowledge, arthrofibrosis after THA has not been described. The aim of this study is to describe the arthrofibrosis of the hip after
Literature data show varying rates of aseptic loosening of standard hemispherical cups after
Aims. The Forgotten Joint Score-12 (FJS-12) is a validated patient-reported outcome measure (PROM) tool designed to assess artificial prosthesis awareness during daily activities following total hip arthroplasty (THA). The patient-acceptable symptom state (PASS) is the minimum cut-off value that corresponds to a patient’s satisfactory state-of-health. Despite the validity and reliability of the FJS-12 having been previously demonstrated, the PASS has yet to be clearly defined. This study aims to define the PASS of the FJS-12 following
Aim. Prosthetic joint infection (PJI) is a serious complication following total hip arthroplasty (THA) entailing increased mortality, decreased quality of life, and high healthcare costs. In 2009 a nationwide, multidisciplinary infection control program was launched in Sweden, PRISS, which aimed to reduce the PJI burden by 50%. The primary aim was to investigate whether the PRISS project reduced PJI incidence after
Periprosthetic femur fracture (PFF) is a major complication following total hip arthroplasty (THA) that carries significant morbidity, mortality, and economic burden. Currently, uncemented stems are highly preferred in
Abstract. Background. Although tantalum is a well recognised implant material used for revision arthroplasty, little is known regarding the use of the same in
Aims. As our population ages, the number of octogenarians who will require a total hip arthroplasty (THA) rises. In a value-based system where operative outcomes are linked to hospital payments, it is necessary to assess the outcomes in this population. The purpose of this study was to compare outcomes of elective,
Detection of clinical situations are the most difficult for
Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point.Aims
Methods
The benefit of using acetabular screws in
Total hip arthroplasty (THA) is one of the most successful and effective treatments for advanced hip osteoarthritis (OA). Over the last 5 years, Canada has seen a 17.8% increase in the number of hip replacements performed annually, and that number is expected to grow along with the aging Canadian population. However, the rise in THA surgery is associated with an increased number of patients at risk for the development of an infection involving the joint prosthesis and adjacent deep tissue – periprosthetic joint infections (PJI). Despite improved hygiene protocols and novel surgical strategies, PJI remains a serious complication. No previous population-based studies has investigated PJI risk factors using a time-to-event approach and none have focused exclusively on patients undergoing THA for primary hip OA. The purpose of this study is to determine risk factors for PJI after
Aim. Two types of national registers surveil infections after
Objectives. High failure rates of metal-on-metal hip arthroplasty implants have highlighted the need for more careful introduction and monitoring of new implants and for the evaluation of the safety of medical devices. The National Joint Registry and other regulatory services are unable to detect failing implants at an early enough stage. We aimed to identify validated surrogate markers of long-term outcome in patients undergoing
The last two decades have seen remarkable technological advances in total hip arthroplasty (THA) implant design. Porous ingrowth surfaces and highly crosslinked polyethylene (HXLPE) have been expected to dramatically improve implant survivorship. The purpose of the present study was to evaluate survival of contemporary cementless acetabular components following
With the introduction of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA), orthopaedic surgeons have moved towards using larger femoral heads at the cost of thinner liners to decrease the risk of instability. Several short and mid-term studies have shown minimal liner wear with the use HXLPE liners, but the safety of using thinner HXPLE liners to maximize femoral head size remains uncertain and concerns that this may lead to premature failure exist. Our objective was to analyze the outcomes for