Results per page:
Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 77 - 77
1 Jan 2003
Rozing PM
Full Access

Introduction. The value of the preoperative radiograph of the rheumatoid shoulder is underestimated for defining the moment for arthroplasty. Larsen grades 4 and 5 are widely used as radiological criterium, but this grading system is not sufficient for staging important surgical aspects as proximal migration and medialisation of the humeral head. The purpose of this study is to analyse the proximal migration and medialisation in severely destructed shoulders (Larsen 4 and 5) and to correlate this with the clinical and per-operative findings to optimize the timing for shoulder arthroplasty. Methods. From a large group of patients with a shoulder arthroplasty those were selected who had preoperatively an involvement of the shoulder graded as Larsen 4 or 5. 104 Rheumatoid patients were selected (29 male, 75 female). The average age was 60 years (range 25–83 yrs). All patients were preoperatively clinically scored with the HSS-score, a 100 points scoring system, which assesses pain, function, power and range of motion. The radiographs were scored for the following items: gleno-humeral joint space, bone loss of glenoid, destruction of the humeral head, proximal migration and involvement of the AC-joint. The most important peroperative items were the quality of the rotator cuff and the glenoid bone mass. Result. 69 Shoulders were graded as Larsen 4 and 35 as Larsen 5. Medialisation by bone loss of the glenoid was moderate in 65% and severe in 13. 6% of the shoulders. Proximal migration was moderate in 22% and severe in 39% of the shoulders. There was no significant correlation between medialisation and proximal migration. The rotator cuff was torn in 44% of the shoulders. Although a torn cuff was significantly related with proximal migration there were many cases with maximal proximal migration with an intact cuff. The clinical scores were not significantly related with the radiographic deterioration of the shoulder. Discussion. Because of the discrepancy between clinical findings and radiographic destruction of the rheumatoid shoulder, the radiographic findings have to play a more important role in the indication of shoulder arthroplasty to achieve a better functional and long-term result


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 68 - 68
1 May 2012
Bucknill A Mingwei J Campton L
Full Access

With the advent of digital radiology, our institution has introduced digital templating for preoperative planning of total hip arthroplasty (THA). Prior studies of the accuracy of digital templating had contradictory results. This study compares the accuracy of digital and analog templating for THA. Ninety patients were recruited. Sixty-eight patients had analog pre-operative templating while 22 patients had digital templating. A retrospective review of medical records obtained the sizes of hip implants inserted during THA and patient demographics. The templated hip sizes were compared with the actual hip implants inserted. Accuracies of both templating methods were compared in four outcomes: prediction of acetabular cup size, prediction of femoral stem size, prediction of femoral offset and prediction of femoral neck length.

Digital templating was more accurate than analog templating in predicting acetabular cup size, femoral stem size and femoral offset. Analog templating was more accurate in predicting femoral neck length. However, only the comparison of femoral offset achieved statistical significance (p-value = 0.049).

After stratifying the data by BMI, digital templating was more accurate than analog templating in predicting acetabular cup and femoral stem sizes for patients with high BMI. For patients with BMI = 25-30, accuracy of digital templating was 100.0% for cup and 80.0% for stem while accuracy of analog templating was 74.1% for cup and 74.1% for stem. For patients with BMI > 30, accuracy of digital templating was 84.6% for cup and 69.2% for stem while that of analog templating was 75.0% for cup and 66.7% for stem.

Digital templating outperformed analog templating in all the outcomes except femoral neck length. In addition, digital templating was significantly more accurate in predicting femoral offset. This study showed that digital templating has the potential to reduce errors in pre-operative planning for THA.


Bone & Joint Open
Vol. 3, Issue 5 | Pages 441 - 447
23 May 2022
Mikkelsen M Wilson HA Gromov K Price AJ Troelsen A

Aims. Treatment of end-stage anteromedial osteoarthritis (AMOA) of the knee is commonly approached using one of two surgical strategies: medial unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA). In this study we aim to investigate if there is any difference in outcome for patients undergoing UKA or TKA, when treated by high-volume surgeons, in high-volume centres, using two different clinical guidelines. The two strategies are ‘UKA whenever possible’ vs TKA for all patients with AMOA. Methods. A total of 501 consecutive AMOA patients (301 UKA) operated on between 2013 to 2016 in two high-volume centres were included. Centre One employed clinical guidelines for the treatment of AMOA allowing either UKA or TKA, but encouraged UKA wherever possible. Centre Two used clinical guidelines that treated all patients with a TKA, regardless of wear pattern. TKA patients were included if they had isolated AMOA on preoperative radiographs. Data were collected from both centres’ local databases. The primary outcome measure was change in Oxford Knee Score (OKS), and the proportion of patients achieving the patient-acceptable symptom state (PASS) at one-year follow-up. The data were 1:1 propensity score matched before regression models were used to investigate potential differences. Results. The matched cohort included 400 patients (mean age 67 years (SD 9.55), 213 (53%) female, mean BMI 30.2 kg/m. 2. , 337 (84%) American Society of Anesthesiologists grade ≤ 2). We found a mean adjusted difference in change score of 3.02 points (95% confidence interval (CI) 1.41 to 4.63; p < 0.001) and a significantly larger likeliness of achieving PASS (odds ratio 3.67 (95% CI 1.73 to 8.45); p = 0.001) both in favour of the UKA strategy. Conclusion. UKA and TKA are both good strategies for treating end-stage AMOA. However, when compared as a strategy, UKA achieved larger improvements in OKS, and were more likely to reach the PASS value at one-year follow-up. Cite this article: Bone Jt Open 2022;3(5):441–447


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 88 - 88
19 Aug 2024
Kendall J Forlenza EM DeBenedetti A Levine BR Valle CJD Sporer S
Full Access

An intra-articular steroid injection can be a useful diagnostic tool in patients presenting with debilitating hip pain and radiographically mild osteoarthritis. The clinical and patient reported outcomes associated with patients who have radiographically mild osteoarthritis and undergo total hip arthroplasty (THA) remain poorly studied. Patients undergoing primary, elective THA at a single academic medical center by a fellowship-trained adult reconstruction surgeon between 2017–2023 were identified. Only those patients who underwent an intra-articular corticosteroid injection into the operative hip within one year of surgery were included. Patients were divided into two cohorts based on the severity of their osteoarthritis as determined by preoperative radiographs; those with Kellgren-Lawrence (KL) grade I-II arthritis were classified as “mild” whereas those with KL grade III-IV arthritis were classified as “severe”. Clinical and patient reported outcomes at final follow-up were compared between cohorts. The final cohorts included 25 and 224 patients with radiographically mild and severe osteoarthritis, respectively. There were no baseline differences in age, gender or time between intra-articular corticosteroid injection and THA between cohorts. There were no significant differences in the preoperative or postoperative HOOS JR values between patients with mild or severe arthritis (all p>0.05). There were no significant differences in the change in HOOS JR scores from the preoperative to final follow-up timepoints between cohorts. There were no significant differences in the percentage of patients who achieved the minimal clinically important difference (MCID) on the HOOS JR questionnaire between cohorts. Patients with radiographically mild osteoarthritis who feel relief of their hip pain following an intra-articular corticosteroid injection report similar preoperative debility and demonstrate similar improvements in patient reported outcome scores following THA compared to patients with radiographically severe osteoarthritis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 8 - 8
1 Dec 2023
Faustino A Murphy E Curran M Kearns S
Full Access

Introduction. Osteochondral lesions (OCLs) of the talus are a challenging and increasingly recognized problem in chronic ankle pain. Many novel techniques exist to attempt to treat this challenging entity. Difficulties associated with treating OCLs include lesion location, size, chronicity, and problems associated with potential graft harvest sites. Matrix associated stem cell transplantation (MAST) is one such treatment described for larger lesions >15mm2 or failed alternative therapies. This cohort study describes a medium-term review of the outcomes of talar lesions treated with MAST. Methods. A review of all patients treated with MAST by a single surgeon was conducted. Preoperative radiographs, MRIs and FAOS outcome questionnaire scores were conducted. Intraoperative classification was undertaken to correlate with imaging. Postoperative outcomes included FAOS scores, return to sport, revision surgery/failure of treatment and progression to arthritis/fusion surgery. Results. 58 MAST procedures in 57 patients were identified in this cohort. The mean follow up was 5 years. There were 20 females and37males, with a mean age of 37 years (SD 9.1). 22 patients had lateral OCLS were and 35 patients had medial OCLs. Of this cohort 32patients had previous surgery and 25 had this procedure as a primary event. 15 patients had one failed previous surgery, 9 patients had two, four patients had three previous surgeries and three patients had four previous surgeries. 12 patients had corrective or realignment procedures at the time of surgery. In terms of complications 3 patients of this cohort went on to have an ankle fusion and two of these had medial malleolar metal work taken out prior to this, 5 patients had additional procedures for arthrofibrotic debridements, 1 patient had a repeat MAST procedure, 1 additional patients had removal of medial malleolar osteotomy screws for pain at the osteotomy site, there were 2 wound complications one related to the ankle and one related to pain at the iliac crest donor site. Conclusion. MAST has demonstrated positive results in lesions which prove challenging to treat, even in a “ failed microfracture” cohort. RCT still lacking in field of orthobiologics for MAST. Longer term follow up required to evaluate durability


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 2 - 2
1 Apr 2022
Jenkinson M Peeters W Hutt J Witt J
Full Access

Acetabular retroversion is a recognised cause of hip impingement. Pelvic tilt influences acetabular orientation and is known to change in different functional positions. While previously reported in patients with developmental dysplasia of the hip, positional changes in pelvic tilt have not been studied in patients with acetabular retroversion. We retrospectively analysed supine and standing AP pelvic radiographs in 22 patients with preoperative radiographs and 47 with post-operative radiographs treated for symptomatic acetabular retroversion. Measurements were made for acetabular index (AI), lateral centre-edge angle (LCEA), crossover index, ischial spine sign, and posterior wall sign. The change in pelvic tilt angle was measured both by the Sacro-Femoral-Pubic (SFP) angle and the Pubic Symphysis to Sacro-iliac (PS-SI) Index. In the supine position, the mean calculated pelvic tilt angle (by SFP) was 1.05° which changed on standing to a pelvic tilt of 8.64°. A significant increase in posterior pelvic tilt angle from supine to standing of 7.59° (SFP angle) and 5.89° (PS –SI index) was calculated (p<0.001;paired t-test). There was a good correlation in pelvic tilt change between measurements using SFP angle and PS-SI index (rho .901 in pre-op group, rho .815 in post-op group). Signs of retroversion were significantly reduced in standing x-rays compared to supine: Crossover index (0.16 vs 0.38; p<0.001) crossover sign (19/28 vs 28/28 hips; p<0.001), ischial spine sign (10/28 hips vs 26/28 hips; p<0.001) and posterior wall sign (12/28 vs 24/28 hips; p<0.001). Posterior pelvic tilt increased from supine to standing in patients with symptomatic acetabular retroversion, in keeping with previous studies of pelvic tilt change in patients with hip dysplasia. The features of acetabular retroversion were much less evident on standing radiographs. The low pelvic tilt angle in the supine position is implicated in the appearance of acetabular retroversion in the supine position. Patients presenting with symptoms of hip impingement should be assessed by supine and standing pelvic radiographs so as not to miss signs of retroversion and to assist with optimising acetabular correction at the time of surgery


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 42 - 42
1 Oct 2018
Schloemann DT Edelstein AI Barrack RL
Full Access

Introduction. Malposition of the acetabular component in total hip arthroplasty (THA) is linked to multiple adverse outcomes. Changes in the sagittal plane position of the pelvis, owing both to patient positioning in the operating room and to altered spinopelvic alignment following surgery, potentially contribute to variation in component position. The dynamics of sagittal plane pelvic position before, during, and after THA have not been defined. We measured the differences in pelvic ratio, a measure of sagittal plane pelvic position, between preoperative, intraoperative, and postoperative anteroposterior (AP) radiographs of patients undergoing THA in the lateral decubitus position. Methods. We retrospectively compared the radiographic pelvic ratio among 90 patients undergoing THA. AP radiographs were obtained in the standing position preoperatively and at 6 weeks after surgery; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post anesthesia care unit (PACU). Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Radlink software was used to determine the pelvic ratio on each radiograph. Changes in apparent cup position based on changes in pelvic ratio were calculated using data from the literature, and a change of at least 10 degrees in acetabular component position was defined as clinically meaningful. Analyses were performed using paired t-tests, with p<0.05 defined as significant. Results. 54% of patients had a change in pelvic ratio large enough to alter the apparent acetabular component anteversion by 10 degrees (49% increased and 6% decreased), and 12% had a change large enough to alter the apparent acetabular component inclination by 10 degrees (12% increased and 0% decreased) when the intraoperative AP radiograph was compared to the preoperative AP radiograph. 36% of patients had a change in pelvic ratio from the preoperative radiograph to the 6 week preoperative radiograph large enough to alter the apparent acetabular component anteversion by 10 degrees (5% increased and 31% decreased), and 8% had a change large enough to alter the apparent acetabular component inclination by 10 degrees (6% increased and 1% decreased). Discussion. Changes in the sagittal plane pelvic position between preoperative, intraoperative, and postoperative radiographs occur in a substantial number of patients. These changes correspond to altered functional position of the acetabular component in over half of patients on the intraoperative radiograph and over one third of patients on postoperative radiographs. This variability suggests that intraoperative imaging may be useful for avoiding outliers of component position, and calls into question the feasibility of achieving targeted component positions based on preoperative imaging alone


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 49 - 49
1 Nov 2021
Peeters W Jenkinson M Hutt J Witt J
Full Access

Acetabular retroversion is a recognised cause of hip impingement. Pelvic tilt influences acetabular orientation and is known to change in different functional positions. While previously reported in patients with developmental dysplasia of the hip, positional changes in pelvic tilt have not been studied in patients with acetabular retroversion. We retrospectively analysed supine and standing AP pelvic radiographs in 22 patients with preoperative radiographs and 47 with post-operative radiographs treated for symptomatic acetabular retroversion. Measurements were made for acetabular index (AI), lateral centre-edge angle (LCEA), crossover index, ischial spine sign, and posterior wall sign. The change in pelvic tilt angle was measured both by the Sacro-Femoral-Pubic (SFP) angle and the Pubic Symphysis to Sacro-iliac (PS-SI) Index. In the supine position, the mean calculated pelvic tilt angle (by SFP) was 1.05° which changed on standing to a pelvic tilt of 8.64°. A significant increase in posterior pelvic tilt angle from supine to standing of 7.59° (SFP angle) and 5.89° (PS –SI index) was calculated (p<0.001;paired t-test). The mean pelvic tilt change of 6.51° measured on post-operative Xrays was not significantly different (p=.650). There was a good correlation in pelvic tilt change between measurements using SFP angle and PS-SI index (rho .901 in pre-op group, rho .815 in post-op group). Signs of retroversion were significantly reduced in standing x-rays compared to supine: Crossover index (0.16 vs 0.38; p<0.001) crossover sign (19/28 vs 28/28 hips; p<0.001), ischial spine sign (10/28 hips vs 26/28 hips; p<0.001) and posterior wall sign (12/28 vs 24/28 hips; p<0.001). Posterior pelvic tilt increased from supine to standing in patients with symptomatic acetabular retroversion, in keeping with previous studies of pelvic tilt change in patients with hip dysplasia. The features of acetabular retroversion were much less evident on standing radiographs. The low pelvic tilt angle in the supine position is implicated in the appearance of acetabular retroversion in the supine position. Patients presenting with symptoms of hip impingement should be assessed by supine and standing pelvic radiographs so as not to miss signs of retroversion and to assist with optimising acetabular correction at the time of surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 56 - 56
1 Feb 2021
Catani F Illuminati A Ensini A Zambianchi F Bazzan G
Full Access

Introduction. Robotics have been applied to total knee arthroplasty (TKA) to improve surgical precision in component placement and joint function restoration. The purpose of this study was to evaluate prosthetic component alignment in robotic arm-assisted (RA)-TKA performed with functional alignment and intraoperative fine-tuning, aiming for symmetric medial and lateral gaps in flexion/extension. It was hypothesized that functionally aligned RA-TKA the femoral and tibial cuts would be performed in line with the preoperative joint line orientation. Methods. Between September 2018 and January 2020, 81 RA cruciate retaining (CR) and posterior stabilized (PS) TKAs were performed at a single center. Preoperative radiographs were obtained, and measures were performed according to Paley's. Preoperatively, cuts were planned based on radiographic epiphyseal anatomies and respecting ±3° boundaries from neutral coronal alignment. Intraoperatively, the tibial and femoral cuts were modified based on the individual soft tissue-guided fine-tuning, aiming for symmetric medial and lateral gaps in flexion/extension. Robotic data were recorded. Results. A total of 56 RA-TKAs performed on varus knees were taken into account. On average, the tibial component was placed at 1.9° varus (SD 0.7) and 3.3° (SD 1.0) in the coronal and sagittal planes, respectively. The average femoral component alignment, based on the soft tissue tensioning with spoons, resulted as follows: 0.7° varus (SD 1.7) in the coronal plane and 1.8° (SD 2.1) of external rotation relative to surgical transepicondylar axis in the transverse plane. A statistically significant linear direct relationship was demonstrated between radiographic epiphyseal femoral and tibial coronal alignment and femoral (r=0.3, p<0.05) and tibial (r=0.3, p<0.01) coronal cuts, resepctively. Conclusion. Functionally aligned RA-TKA performed in varus knees, aiming for ligaments’ preservation and balanced flexion/extension gaps, provided joint line respecting femoral and tibial cuts on the coronal plane


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 79 - 79
1 Feb 2017
Cooper J Koenig J Hepinstall M Rodriguez J
Full Access

Introduction. Prosthetic replacement remains the treatment of choice for displaced femoral neck fractures in the elderly population, with recent literature demonstrating significant functional benefits of total hip arthroplasty (THA) over hemiarthroplasty. Yet the fracture population also has historically high rates of early postoperative instability when treated with THA. The direct anterior approach (DAA) may offer the potential to decrease the risk of postoperative instability in this high-risk population by maintaining posterior anatomic structures. The addition of intraoperative fluoroscopy can improve precision in component placement and overcome limitations on preoperative planning due to poor preoperative radiographs performed in the emergency setting. Methods. We retrospectively reviewed clinical and radiographic outcomes of 113 consecutive patients with displaced femoral neck fractures treated by two surgeons over a five-year period. All underwent surgery via the DAA using fluoroscopic guidance, and were allowed immediate postoperative weight bearing without any hip precautions or restrictions. Charts were reviewed for relevant complications, while radiographs were reviewed for component positioning, sizing, and leg length discrepancy. Mean follow-up was 8.9 months. Results. Mean age was 79.3 years (range, 42 to 101), 73% of patients were women, and mean BMI was 22.6 kg/m. 2. Ninety patients (80%) received THA while 23 (20%) received unipolar or bipolar hemiarthroplasty. Mean acetabular anteversion was 15.0 degrees (range, 4 to 24) and mean abduction was 39.2 degrees (range, 27 to 51) with 95% of acetabular components in the combined safe zone as described by Lewinnek. Mean radiographic leg-length difference was +2.2 mm (range, −4.9 to +8.8mm). There was no femoral stem subsidence of more than 2mm. Only one patient (0.9%) dislocated postoperatively, who was eventually constrained for recurrent posterior instability 3 months following surgery. Delayed wound healing (6.1%) was the most common postoperative complication. Conclusions. The direct anterior approach allows a safe, effective, and reproducible approach for treatment of displaced femoral neck fractures, with very low rate of early postoperative instability compared to historical controls. The use of intraoperative fluoroscopy allows excellent component positioning, sizing, and restoration of leg length in spite of inconsistent preoperative radiographs


Bone & Joint Research
Vol. 10, Issue 12 | Pages 830 - 839
15 Dec 2021
Robertson G Wallace R Simpson AHRW Dawson SP

Aims. Assessment of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA) is a well-established clinical technique, but it is not available in the acute trauma setting. Thus, it cannot provide a preoperative estimation of BMD to help guide the technique of fracture fixation. Alternative methods that have been suggested for assessing BMD include: 1) cortical measures, such as cortical ratios and combined cortical scores; and 2) aluminium grading systems from preoperative digital radiographs. However, limited research has been performed in this area to validate the different methods. The aim of this study was to investigate the evaluation of BMD from digital radiographs by comparing various methods against DXA scanning. Methods. A total of 54 patients with distal radial fractures were included in the study. Each underwent posteroanterior (PA) and lateral radiographs of the injured wrist with an aluminium step wedge. Overall 27 patients underwent routine DXA scanning of the hip and lumbar spine, with 13 undergoing additional DXA scanning of the uninjured forearm. Analysis of radiographs was performed on ImageJ and Matlab with calculations of cortical measures, cortical indices, combined cortical scores, and aluminium equivalent grading. Results. Cortical measures showed varying correlations with the forearm DXA results (range: Pearson correlation coefficient (r) = 0.343 (p = 0.251) to r = 0.521 (p = 0.068)), with none showing statistically significant correlations. Aluminium equivalent grading showed statistically significant correlations with the forearm DXA of the corresponding region of interest (p < 0.017). Conclusion. Cortical measures, cortical indices, and combined cortical scores did not show a statistically significant correlation to forearm DXA measures. Aluminium-equivalent is an easily applicable method for estimation of BMD from digital radiographs in the preoperative setting. Cite this article: Bone Joint Res 2021;10(12):830–839


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 16 - 16
1 Oct 2020
Anderson LA Wylie J Erickson JA Peters CL
Full Access

Introduction. Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular work such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose of this review was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary PAO cohort with no intra-articular work performed at the time of PAO. Methods. From June 2012 to September 2019, 272 Rectus Sparing PAOs were performed and followed for a minimum of one year (mean 4.6 years). The average age was 24 (range 14–44) and 87% were female. The average BMI was 25 and average length of hospital stay was 2.9 days. Patients were evaluated at last follow-up with PROMIS PF-CAT, pain and mental health scores. Clinical records were reviewed for complications or subsequent surgery. Pre and post-operative radiographs were reviewed for change in the following acetabular parameters: LCEA, ACEA, AI, and the alpha-angle was obtained from preoperative radiographs. Patients were cross-referenced from the two largest hospital systems in our area to determine if subsequent HA was performed. Descriptive statistics and logistic regression were used to analyze risk factors for HA. Results. 13 hips (12 patients) (4.8%) underwent subsequent HA with labral repair and femoral-osteochondroplasty most common. No hips underwent THA and one revision PAO was performed. 13 hips experienced a complication and 90 hips underwent hardware removal. All PROM improved significantly post-operatively. Radiographically 80% of hips were in goal for acetabular correction parameters and amongst the LCEA, ACEA, AI and alpha angle (AA), only the AA was significant risk factor for subsequent arthroscopy. Conclusion. Rectus sparing PAO is associated with a low rate of subsequent HA for intra-articular pathology at 5-year follow-up. Acetabular correction alone may be sufficient for the majority of patients with symptomatic acetabular dysplasia


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 145 - 145
1 Jul 2020
Sprague S Okike K Slobogean G Swiontkowski Bhandari M Udogwu UN Isaac M
Full Access

Internal fixation is currently the standard of care for Garden I and II femoral neck fractures in the elderly. However, there may be a degree of posterior tilt on the preoperative lateral radiograph above which failure is likely, and primary arthroplasty would be preferred. The purpose of this study was to determine the association between posterior tilt and the risk of subsequent arthroplasty following internal fixation of Garden I and II femoral neck fractures in the elderly. This study represents a secondary analysis of data collected in the FAITH trial, an international multicenter randomized controlled trial comparing the sliding hip screw to cannulated screws in the management of femoral neck fractures in patients aged 50 years or older. For each patient who sustained a Garden I or II femoral neck fracture and had an adequate preoperative lateral radiograph, the amount of posterior tilt was categorized as < 2 0 degrees or ≥20 degrees. Multivariable Cox proportional hazards analysis was used to assess the association between posterior tilt and subsequent arthroplasty during the two-year follow-up period, while controlling for potential confounders. Of the 555 patients in the study sample, posterior tilt was classified as ≥20 degrees for 67 (12.1%) and < 2 0 degrees for 488 (87.9%). Overall, 13.2% (73/555) of patients underwent subsequent arthroplasty in the 24-month follow-up period. In the multivariable analysis, patients with posterior tilt ≥20 degrees had a significantly increased risk of subsequent arthroplasty compared to those with posterior tilt < 2 0 degrees (22.4% (15/67) vs 11.9% (58/488), Hazard Ratio (HR) 2.22, 95% confidence interval (CI) 1.24–4, p=0.008). The other factor associated with subsequent arthroplasty was age ≥80 (p=0.03). In this study of patients with Garden I and II femoral neck fractures, posterior tilt ≥20 degrees was associated with a significantly increased risk of subsequent arthroplasty. Primary arthroplasty should be considered for Garden I and II femoral neck fractures with posterior tilt ≥20 degrees, especially among older patients


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 1 - 1
1 Mar 2020
Keenan O Holland G Maempel J Keating J Scott C
Full Access

Though knee osteoarthritis (OA) is diagnosed and monitored radiographically, full thickness cartilage loss (FTCL) has rarely been correlated with radiographic classification. This study aims to analyse which classification system correlates best with FTCL and assessing their reliability. Prospective study of 300 consecutive patients undergoing total knee arthroplasty (TKA) for OA. Two blinded examiners independently graded preoperative radiographs using 5 systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlback. Interobserver agreement was assessed using the intraclass correlation coefficient. Intraoperatively, anterior cruciate ligament (ACL) status and FTCL in 16 regions of interest were recorded. Radiographic classification and FTCL were correlated using the Spearman correlation coefficient. On average, each knee had 6.8±3.1 regions of FTCL, most common medially. The commonest patterns of FTCL were medial with patellofemoral (48%) and tricompartmental (30%). ACL status was associated with pattern of FTCL (p=0.02). All classification systems demonstrated moderate ICC, but this was highest for IKDC: whole knee 0.68 (95%CI 0.60–0.74); medial compartment 0.84 (0.80–0.87); and lateral compartment 0.79 (0.73–0.83). Correlation with FTCL was strongest for Ahlback (Spearman rho 0.27–0.39) and KL (0.30–0.33), though all systems demonstrated medium correlation. The Ahlback was the most discriminating in severe OA. Osteophyte presence in the medial compartment had high positive predictive value for FTCL, but not in the lateral compartment. The Ahlback and KL systems had the highest correlation with confirmed cartilage loss. However, the IKDC system displayed best interobserver reliability, with favourable correlation with FTCL in medial and lateral compartments, though less discriminating in severe disease


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 16 - 16
1 Nov 2019
Saha S Rex C Premanand C Niraj T
Full Access

Purpose. Isolated fractures of femoral condyle in the coronal plane (Hoffa fracture) is rare and is surgically challenging to treat. 44 patients were operated between 2004–2014. The aim was to retrospectively assess the fracture patterns, fixation done and functional outcome. Methods. All injuries resulted from direct trauma to the knee out of which 36 were due to road traffic accidents.38 were closed injuries and the rest open.35 involved lateral condyle, 8 involved medial condyle and one was bicondylar type. All were anatomically reduced with fixation decided based on preoperative radiographs, CT scan and intra-op observation. Early passive motion and isometric exercises were started but kept non-weight bearing for 6–8 weeks. The mean follow up period was five years. Outcomes were measured using Neer's scoring system and International Knee Society Documentation Committee (IKDC) Functional Score. Results. 26 patients had excellent outcome, 14 had satisfactory and 4 had unsatisfactory outcome which corresponded with the specified fracture severity pattern. Uniformly excellent results were obtained in all simple pattern fractures, whereas comminuted fracture patterns were more challenging to treat with variable outcomes. Conclusion. In our retrospective observational study, we found that each fracture had specific pattern which dictated the treatment plan and the prognosis. Subsequently we grouped the fractures and proposed a classification system that would specify the pattern of fracture and dictate the type of fixation preferred. We conclude that therapeutic outcome is significantly affected by the amount of articular surface comminution, posterior cortex comminution, attainment of anatomical reduction and stable fixation


Bone & Joint Research
Vol. 9, Issue 4 | Pages 182 - 191
1 Apr 2020
D’Ambrosio A Peduzzi L Roche O Bothorel H Saffarini M Bonnomet F

Aims. The diversity of femoral morphology renders femoral component sizing in total hip arthroplasty (THA) challenging. We aimed to determine whether femoral morphology and femoral component filling influence early clinical and radiological outcomes following THA using fully hydroxyapatite (HA)-coated femoral components. Methods. We retrospectively reviewed records of 183 primary uncemented THAs. Femoral morphology, including Dorr classification, canal bone ratio (CBR), canal flare index (CFI), and canal-calcar ratio (CCR), were calculated on preoperative radiographs. The canal fill ratio (CFR) was calculated at different levels relative to the lesser trochanter (LT) using immediate postoperative radiographs: P1, 2 cm above LT; P2, at LT; P3, 2 cm below LT; and D1, 7 cm below LT. At two years, radiological femoral component osseointegration was evaluated using the Engh score, and hip function using the Postel Merle d’Aubigné (PMA) and Oxford Hip Score (OHS). Results. CFR was moderately correlated with CCR at P1 (r = 0.44; p < 0.001), P2 (r = 0.53; p < 0.001), and CFI at P1 (r = − 0.56; p < 0.001). Absence of spot welds (n = 3, 2%) was associated with lower CCR (p = 0.049), greater CFI (p = 0.017), and lower CFR at P3 (p = 0.015). Migration (n = 9, 7%) was associated with lower CFR at P2 (p = 0.028) and P3 (p = 0.007). Varus malalignment (n = 7, 5%), predominantly in Dorr A femurs (p = 0.028), was associated with lower CFR at all levels (p < 0.05). Absence of spot welds was associated with lower PMA gait (p = 0.012) and migration with worse OHS (p = 0.032). Conclusion. This study revealed that femurs with insufficient proximal filling tend to have less favourable radiological outcomes following uncemented THA using a fully HA-coated double-tapered femoral component. Cite this article: Bone Joint Res. 2020;9(4):182–191


Bone & Joint Open
Vol. 3, Issue 2 | Pages 158 - 164
17 Feb 2022
Buddhdev P Vallim F Slattery D Balakumar J

Aims. Slipped upper femoral epiphysis (SUFE) has well documented biochemical and mechanical risk factors. Femoral and acetabular morphologies seem to be equally important. Acetabular retroversion has a low prevalence in asymptomatic adults. Hips with dysplasia, osteoarthritis, and Perthes’ disease, however, have higher rates, ranging from 18% to 48%. The aim of our study was to assess the prevalence of acetabular retroversion in patients presenting with SUFE using both validated radiological signs and tomographical measurements. Methods. A retrospective review of all SUFE surgical cases presenting to the Royal Children’s Hospital, Melbourne, Australia, from 2012 to 2019 were evaluated. Preoperative plain radiographs were assessed for slip angle, validated radiological signs of retroversion, and standardized postoperative CT scans were used to assess cranial and mid-acetabular version. Results. In all, 116 SUFEs presented in 107 patients who underwent surgical intervention; 47 (52%) were male, with a mean age of 12.7 years (7.5 to 16.6). Complete radiological data was available for 91 patients (99 hips) with adequate axial CT imaging of both hips. Overall, 82 patients (82%) underwent pinning in situ (PIS), with subcapital realignment surgery (SRS) performed in 17 patients (18%) (slip angles > 75°). Contralateral prophylactic PIS was performed in 72 patients (87%). On the slip side, 62 patients (68%) had one or more radiological sign of retroversion. Tomographical acetabular retroversion was more pronounced cranially than caudally of the acetabulum on both the affected side and the contralateral side (p < 0.001) as expected in the normal population. Increasing severity of the slip was found to be directly proportional to the degree of reduction in cranial and central acetabular version (p < 0.05) in the SUFE hips. Conclusion. Acetabular retroversion is more prevalent in patients with SUFE than previously reported, and have been shown be correlated to the severity of the slip presentation. The presence of radiological signs of acetabular retroversion could be used to justify prophylactic contralateral pinning. Cite this article: Bone Jt Open 2022;3(2):158–164


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 26 - 26
1 May 2019
King R Wang X Qureshi A Vepa A Rahman U Palit A Williams M Elliott M
Full Access

Background. Over 10% of total hip arthroplasty (THA) surgeries performed in England and Wales are revision procedures. 1. Malorientation of the acetabular component in THA may contribute to premature failure due to mechanisms such as edge loading and prosthetic impingement. It is known that the pelvis flexes and extends during activities of daily living (ADLs), and excessive pelvic motion can contribute to functional acetabular malorientation. Preoperative radiographs can be performed to measure changes in pelvic tilt during ADLs to identify high risk individuals and inform surgical decision making. However, radiographs require time-consuming radiation exposure, and are unable to provide truly dynamic 3-dimensional analysis. The purpose of this study was to develop and evaluate a motion capture method using inertial measurement units (IMUs). This would provide a rapid, non-invasive analysis of pelvic tilt which could be used to support surgical planning. Methods. Patients awaiting THA were fitted with a bespoke device consisting of a 3D-printed clamp which housed the IMU and positioned over the sacrum. A wide elastic belt was fitted around the patient's waist to keep the device in place. Movement data was transmitted wirelessly to a tablet computer. Pelvic tilt was measured in standing, flexed seated and step-up positions while undergoing X-rays with the IMU capturing the data in parallel. Statistical analysis included measures of correlation between the X-ray and IMU measurements. Results. Measurements from 30 patients indicated a moderate-strong correlation (R. 2. = .87; Figure 1) between IMU and radiological measures of AP pelvic tilt. Conclusions. A novel device has been developed that can suitably track pelvic movements. This could potentially be used to identify patients with large changes in pelvic tilt, and thereby inform surgical planning. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 93 - 93
1 Feb 2020
Ta M Nachtrab J LaCour M Komistek R
Full Access

Introduction. Conventional hip radiographs allow surgeons, during preoperative planning, to make important decisions. Size and location of implants are routinely measured by overlaying schematics of the implanted components onto preoperative radiographs. Most currently available planning tools are in two-dimensions (2D), using X-ray images and 2D templates of the implants. Determination of the ideal component size requires two radiographic views of the femur: the anterior-posterior (AP) and the lateral direction. The surgeon uses this information to determine component sizes. Even though this approach has been used for many years leading to very good results, this manual process potentially carries multiple shortcomings. The biggest issue with the AP X-ray image is the fact that it is 2D in nature while the measurement's objective is to obtain three-dimensional (3D) parameters. Objective. The objective of this study is to derive a methodology to automatically select correct THA implant sizes while keeping the anatomical center of each specific patient within a forward solution model (FSM) that predicts post-operative outcomes. Methods. The femoral components in our process contain five parameters: stem length, neck offset, neck length, neck shaft angle, and component width. There are many steps to measure the morphologic parameters of a femoral component. (1)Preparation of training implant database, (2)defining multi-plane intersection, (3)determining circumcircles for all intersected femoral component contours, (4)finding centers and radii of circumcircles, (5)measuring distances from each circumcircle to the femoral component head center, and (6)determining the stem shaft axis. The FSM fits specific femoral canal using a 3D mesh model of the femur. The femoral component and canal morphology of a femur model are compared to the training femoral component database. For each femoral component morphology, the algorithm determines how far distally the femoral component fits within the canal before collision between the stem and cortical bone. Once the defined position is confirmed, the relative distance from the anatomical femoral head center to the femoral component head center is calculated. This process is repeated for all femoral component morphology. The best fitting femoral component is determined when the distance from its head center to the femoral head center is minimized, Figure 1. Results. Three intensive validation tools have been developed: (1) cross-sectional analysis, (2) slice analysis, and (3) contact map analysis. Cross-sectional analysis is a graphic interaction program where users can freely view the anatomy at any orientation, Figure 2. The slice analysis enhances the user visualization by providing a static view of the fit between chosen femoral component and femoral canal, Figure 3. Finally, the contact map analysis allows for visualization of contact area through the bone-stem interface. Conclusion and Discussion. This is a powerful tool with the FSM that allows surgeons to get a “best fit” implant in 3D, based on canal fit and distance from anatomical femoral head center. Surgeons may want to manually size up or down, but the program will pick best fit sizes based on anatomical morphology. Future iterations will consider the reaming depth each surgeon uses to improve implant selection for each surgeon's technique. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 10 - 10
1 Mar 2009
Chidambaram R Kachramanoglou C Mok D
Full Access

Aim: To evaluate the radiographs of proximal humeral fractures in an attempt to define a diagnostic sign as a predictor of four-part fracture. Diagnostic sign: The normal humeral head articular surface points towards the glenoid. We describe our ‘sunset’ sign as ‘articular surface of humeral head pointing away from the glenoid and tilted upwards, in the presence of a displaced greater tuberosity fracture’. We postulate that a patient with proximal humerus fracture showing this sign has four-part fracture until proved otherwise. Materials and Methods: Between 2002 and 2006, 80 consecutive patients underwent open reduction and internal fixation of their proximal humeral fractures in our Shoulder unit. We reviewed their preoperative radiographs and operative notes retrospectively. 79 patients were included in the study as one patient’s pre-operative radiograph was not available. The AP radiograph was evaluated independently by three observers who were blinded to the identity of the patients and their operative diagnosis. The presence of ‘sunset’ sign was recorded. There was 90% inter-observer agreement. In the remaining 10%, a consensus review was performed as to the presence of sign for evaluation purpose. The findings were then correlated with the operative findings to confirm whether they were four-part fractures or not. With 95% confidence interval we calculated the sensitivity, specificity, and positive and negative predictive values for our diagnostic sign. Results: 30 out of 79 patients displayed ‘sunset’sign in their preoperative radiograph. Of these 28 had confirmed four-part fractures operatively. The positive predictive value of ‘sunset’ sign in diagnosis the four-part fracture was 93%. The specificity and sensitivity were 95% and 78% respectively. The sensitivity was affected by 8 patients with four part fractures with displaced articular head fragment which had dropped either medially or posteriorly. Conclusion: Our results suggest that in patients with proximal humeral fractures, the presence of ‘sunset’sign in the anteroposterior radiograph is a reliable indicator of four-part fracture