Objectives. It has been hypothesized that
Our study aims were to establish correlations between the incidence of
Aim. To determine differences in knee valgus angles produced during a single leg squat and hip muscle strength between healthy subjects and patients with
Background: The role of frontal plane tibiofemoral alignment in subjects with
Introduction. We have been re-evaluating patellofemoral alignment after total knee arthroplasty (TKA) by using a weight- bearing axial radiographic view after detecting
Kinematics of the knee change during the full range of flexion [1]. The lateral femoral condyle (LFC) rolls back progressively through the entire range of flexion. The medial femoral condyle (MFC) does not move back during the first 110 degrees, but from 110 to 160 degrees it moves back by 10mm. This dual arc makes anatomical knee design a challenging task. In medial rotation, during flexion, the MFC stays in place, but the LFC moves forward in extension and backward in flexion. In lateral rotation the LFC stays still while the MFC moves back and forward in flexion and extension. During central rotation both condyles move reciprocally. However the knee is stable against an anteriorly or posteriorly directed force. It is important that all these degrees of freedom and stability are reproduced in total knee replacement (TKR) design. Furthermore, the two femoral condyles together form a spiral. Like the threads of a screw in a nut they allow medio-lateral translation of the femur [2] in the tibial reference frame. During flexion the knee centre moves laterally nearly 20% of the width of the tibial plateau and in extension the femur translates medially. This medio-lateral translation occurs in the natural normal knee joint. This has special significance in knee design because the natural femur (along with the trochlea) moves laterally in flexion, allowing the patella to be sited laterally, while most regular TKRs drive the patella medially. In order to test this anomaly we studied
Each of the seven cuts required for a total knee arthroplasty has its own science, and can affect the outcome of surgery. Distal Femur. Sets the axial alignment (along with the tibial cut), and too little or too much depth affects ligament tension in extension. Anterior Femur. Sets the rotation of the femoral component, which affects patellar tracking. Internal rotation results in
Introduction. Fifteen percent of the primary total knee arthroplasties (TKA) fails within 20 years. Among the main causes for revision surgery are instability and
Introduction. Tibial tuberosity and trochlear groove (TT-TG) distance has been investigated for the patients with primary patellofemoral subluxation/dislocation. To date, TT-TG distance after TKA has not been evaluated, and the effect of postoperative TT-TG distance on patellar tracking is unknown. The purpose of the current study was to investigate the effect of TT-TG distance and rotational position of the femoral and tibial components on patellar tilt after TKA. Methods. Consecutive 115 knees for the diagnosis of osteoarthritis were included in the current study. TKA was performed using posterior cruciate ligament sacrificed prosthesis. A total of 17 men and 96 women with an average age of 75.3 years were included at the time of the surgery. Computed tomography (CT) was taken after TKA in full extension. Postoperative TT-TG distance was measured as a reference of surgical epicondylar axis (SEA) of the femur. Patellar tilt was defined as the angle of the patellar component relative to SEA. Femoral and tibial component rotation was measured as the angle relative to SEA and tibial antero-posterior (AP) axis. Tibial AP axis was defined as the line connecting medial one-third of the tibial tuberosity and center of medial-lateral width. Pearson correlation coefficients were calculated to determine the correlations between patellar tilt and TT-TG distance and between patellar tilt and femoral and tibial component rotation. Results. TT-TG distance had significant correlation with patellar tilt (Figure 1; r = 0.254, p = 0.006), whereas femoral component rotation (p = 0.092) and tibial component rotation (p = 0.062) were not correlated with patellar tilt. Concerning the effect on TT-TG distance, femoral component rotation (r = 0.248, p = 0.008) and tibial component rotation (r = −0.567, p < 0.001) were correlated with TT-TG distance. Conclusion. The current study investigated the effect of TT-TG distance on patellar tilt with postoperative CT scan. Greater TT-TG distance resulted in more patellar tilt, which might have negative effects on patellar tracking. In previous clinical studies, femoral component and tibial component rotation affected
Abstract. Objectives. Patella resurfacing in primary total knee arthroplasty (TKA) remains a contentious issue. Australian rates of patellar resurfacing are 66.6%, significantly higher compared to UK rates of 8–15% and Swedish rates of 2%. Resurfacing has gained popularity in Australia since registry data has shown decreased revision rates with no increase in patellar component related complications. We present for discussion an analysis of 113,694 total knee arthroplasties using commonly implanted prostheses in the UK. Methods. We included all TKA's since the Australian register's conception on 01/09/1999 for a primary diagnosis of osteoarthritis involving the use of either the Triathlon or Duracon implant with and without patellar components. The primary outcome of the study was time to revision for Triathlon's resurfaced and non-resurfaced prosthesis compared to the Duracon's equivalent data. We also analysed the reasons for revision between the 4 groups, type of revision and complication rates. We then compared minimally stabilised and posterior stabilised prostheses. Results. The cumulative revision rate for Triathlon prostheses with resurfacing after 12 years was 3.2% (95% CI, 2.9% to 3.6%) compared to 5.6% (95% CI, 5.0% to 6.2%) without resurfacing. Duracon's equivalent data was 6.3% with resurfacing and 5.9% without resurfacing. Triathlon prosthesis with resurfacing have much lower rates of revision due to loosening,
The October 2012 Knee Roundup. 360. looks at: autologous chondrocytes and chondromalacia patellae; drilling the femoral tunnel at ACL reconstruction; whether we repair the radially torn lateral meniscus; factors associated with
Objectives. Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including
With the success of the medial parapatellar approach (MPA) to total knee arthroplasty (TKA), current research is aimed at reducing iatrogenic microneurovascular and soft tissues damage to the knee. In an effort to avoid disruption to the medial structures of the knee, we propose a novel quadriceps-sparing, subvastus lateralis approach (SLA) to TKA. The aim of the present study is to compare if a SLA can provide adequate exposure of the internal compartment of the knee while reducing soft tissue damage, compared to the MPA. Less disruption of these tissues could translate to better patient outcomes, such as reduced post-operative pain, increased range of motion, reduced instances of
Purpose. To validate accuracy of transepicondylar axis as a reference for femoral component rotation in primary total knee arthroplasty. Methods. A prospective study done from dec 2010 to dec 2011 at tertiary centre. 80 knees were included (43 females and 21 males). All surgeries were carried out by one senior arthroplasty surgeon. All patients undergoing primary total knee replacement were included and all revision cases were excluded. Intraoperative assessment of TEA was done by palpating most prominent point on lateral epicondyle and sulcus on medial epicondyle and passing a k wire through it. Confirmation is done under image intensifier C arm with epicondylar view. Postoperative TEA was assessed by taking CT scan, measuring condylar twist angle and posterior condylar angle. Also correlation of femoral component rotation with postoperative anterior knee pain was assessed. Results. The mean PCA was around 4° with TEA as reference and only 10% patients required an additional lateral release of which 2% patient had preop
Purpose:. To compare accuracy of transepicondylar axis as a reference for femoral component rotation in primary navigated versus non navigated total knee arthroplasty in severely deformed knees. Methods:. A prospective study done from dec 2009 to dec 2011 at tertiary centre. 180 knees were included (124 females and 56 males). All cases were randomly allocated into 2 groups: navigated and non navigated. All surgeries were carried out by two senior arthroplasty surgeons. All patients undergoing primary total knee replacement were included and all revision cases were excluded. Intraoperative assessment of TEA was done by palpating most prominent point on lateral epicondyle and sulcus on medial epicondyle and passing a k wire through it. Confirmation is done under image intensifier C arm with epicondylar view in Non navigated knees. Postoperative TEA was assessed by taking CT scan, measuring condylar twist angle and posterior condylar angle (PCA). Results:. The mean PCA was around 4° with TEA as reference in Navigated and 6° in Non navigated knees and only 7% patients required an additional lateral release of which 2% patient had preop
Introduction.
Treatment of the young patient with medial compartment arthritis and a PCL deficient knee is a complex problem. This study evaluates the efficacy of the anteromedial opening wedge osteotomy for PCL deficient knees with medial compartment degenerative changes. Eighteen patients have undergone an anteromedial opening wedge high tibial osteotomy for the PCL deficient varus knee. Patients were evaluated prospectively pre-operatively and at one and five years post surgery by visual analogue pain scores and
Patella recurrent dislocation and
The aim of this study was to evaluate the efficacy of the anteromedial opening wedge osteotomy for PCL deficient varus knees with medial compartment degenerative changes. Twelve patients had undergone an anteromedial opening wedge high tibial osteotomy for the PCL deficient varus knee using a Puddu plate. All patients were followed for a minimum of one year. Patients were evaluated prospectively pre-operatively and at follow up by visual analogue pain and
INTRODUCTION. Over the past 40 years of knee arthroplasty, significant advances have been made in the design of knee implants, resulting in high patient satisfaction. Patellar tracking has been central to improving the patient experience, with modern designs including an optimized Q-angle, deepened trochlear groove, and thin anterior flange.[1–4] Though many of today's femoral components are specific for the left and right sides, Total Joint Orthopedics’ (TJO) Klassic® Knee System features a universal design to achieve operating room efficiencies while providing all the advancements of a modern knee. The Klassic Femur achieves this through a patented double Q-angle to provide excellent patellar tracking whether implanted in the left or the right knee (Figure 1). The present study examines a prospective cohort of 145 consecutive TKA's performed using a modern universal femur and considers patients’ pre- and post-operative Knee Society Clinical Rating System score (KSS). METHODS AND MATERIALS. 145 primary total knee arthroplasties (TKA) were performed during the study using a measured resection technique with a slope-matching tibial cut for all patients. The posterior cruciate ligament (PCL) was sacrificed to accommodate an ultra-congruent polyethylene insert. The distal femur was cut at five degrees (5°) valgus; the tibia was resected neutral (0°) alignment for valgus legs and in two degrees (2°) of varus for varus alignment. The patella was resurfaced for all patients. Patients were followed annually for up to 46 months and were evaluated using the KSS score on a 200-point scale. RESULTS. The final study group comprised 127 primary TKAs. The average age was 68 years (51–90) with 45 males and 68 females. The average weight was 110kg (range: 75–151kg) for men and 88kg (range: 50–129kg) for women. One patient deceased during the follow-up period, four required manipulation under anesthesia, and two required revision for periprosthetic joint infection. There were no failures due to