Bone & Joint Research
Vol. 5, Issue 9 | Pages 379 - 386
1 Sep 2016
Pahuta M Smolders JM van Susante JL Peck J Kim PR Beaule PE

Objectives. Alarm over the reported high failure rates for metal-on-metal (MoM) hip implants as well as their potential for locally aggressive Adverse Reactions to Metal Debris (ARMDs) has prompted government agencies, internationally, to recommend the monitoring of patients with MoM hip implants. Some have advised that a blood ion level >7 µg/L indicates potential for ARMDs. We report a systematic review and meta-analysis of the performance of metal ion testing for ARMDs. Methods. We searched MEDLINE and EMBASE to identify articles from which it was possible to reconstruct a 2 × 2 table. Two readers independently reviewed all articles and extracted data using explicit criteria. We computed a summary receiver operating curve using a Bayesian random-effects hierarchical model. Results. Our literature search returned 575 unique articles; only six met inclusion criteria defined a priori. The discriminative capacity of ion tests was homogeneous across studies but that there was substantial cut-point heterogeneity. Our best estimate of the “true” area under curve (AUC) for metal ion testing is 0.615, with a 95% credible interval of 0.480 to 0.735, thus we can state that the probability that metal ion testing is actually clinically useful with an AUC ≥ 0.75 is 1.7%. Conclusion. Metal ion levels are not useful as a screening test for identifying high risk patients because ion testing will either lead to a large burden of false positive patients, or otherwise marginally modify the pre-test probability. With the availability of more accurate non-invasive tests, we did not find any evidence for using blood ion levels to diagnose symptomatic patients. Cite this article: M. Pahuta, J. M. Smolders, J. L. van Susante, J. Peck, P. R. Kim, P. E. Beaule. Blood metal ion levels are not a useful test for adverse reactions to metal debris: a systematic review and meta-analysis. Bone Joint Res 2016;5:379–386. DOI: 10.1302/2046-3758.59.BJR-2016-0027.R1


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1455 - 1462
1 Nov 2016
Matharu GS Berryman F Brash L Pynsent PB Dunlop DJ Treacy RBC

Aims. We investigated whether blood metal ion levels could effectively identify patients with bilateral Birmingham Hip Resurfacing (BHR) implants who have adverse reactions to metal debris (ARMD). Patients and Methods. Metal ion levels in whole blood were measured in 185 patients with bilateral BHRs. Patients were divided into those with ARMD who either had undergone a revision for ARMD or had ARMD on imaging (n = 30), and those without ARMD (n = 155). Receiver operating characteristic analysis was used to determine the optimal thresholds of blood metal ion levels for identifying patients with ARMD. Results. The maximum level of cobalt or chromium ions in the blood was the parameter which produced the highest area under the curve (91.0%). The optimal threshold for distinguishing between patients with and without ARMD was 5.5 µg/l (83.3% sensitivity, 88.4% specificity, 58.1% positive and 96.5% negative predictive values). Similar results were obtained in a subgroup of 111 patients who all underwent cross-sectional imaging. Between 3.2% and 4.3% of patients with ARMD were missed if United Kingdom (7 µg/l) and United States (10 µg/l) authority thresholds were used respectively, compared with 2.7% if our implant specific threshold was used, though these differences did not reach statistical significance (p ≥ 0.248). Conclusion. Patients with bilateral BHRs who have blood metal ion levels below our implant specific threshold were at low-risk of having ARMD. Cite this article: Bone Joint J 2016;98-B:1455–62


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 97 - 97
1 Dec 2020
French J Bramley P Scattergood S Sandiford N
Full Access

Objectives. Modular dual-mobility (MDM) constructs are used to reduce dislocation rates after total hip replacement (THR). They combine the advantages of dual mobility with the option of supplementary acetabular screw fixation in complex revision surgery. However, there are concerns about adverse reaction to metal debris (ARMD) as a result of fretting corrosion between the metal liner and shell. Methods: The aim of this systematic review was to find and review all relevant studies to establish the outcomes and risks associated with MDM hip replacement. All articles on MDM THRs in the Medline, EMBASE, CINAHL, Cochrane Library, and Prospero databases were searched. A total of 14 articles were included. A random intercept logistic regression model was used for meta-analysis, giving estimated average values. Results: There were 6 cases of ARMD out of 1312 total. Estimated median incidence of ARMD from meta-analysis was 0.3% (95% CI 0.1 – 1.4%). Mean postoperative serum Cobalt was 0.81 μg/L (95% CI 0.33 – 1.29 μg/L), and Chromium was 0.77 μg/L (95% 0.35 – 1.19 μg/L), from 279 cases in 7 studies. Estimated median incidence of a serum cobalt or chromium ion measurement ≥1 μg/L was 7.9% (95% CI 3.5 – 16.8%), and ≥7 μg/L was 1.8% (95% CI 0.7 – 4.2%). Conclusions: ARMD is a rare but significant complication following total hip replacement using a MDM construct. Its incidence appears higher than that reported in non-metal-on-metal (MoM) hip replacements but lower than that of MoM hip replacements. MDM hip replacements are associated with raised serum metal ion levels postoperatively, but there was no correlation with worse clinical hip function within studies. Studies were poor quality and at high risk of confounding. Pending further work, MDM constructs should be used with caution, reserved for select cases at particularly high risk of dislocation


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 22 - 22
1 Dec 2022
Werle J Kearns S Bourget-Murray J Johnston K
Full Access

A concern of metal on metal hip resurfacing arthroplasty is long term exposure to Cobalt (Co) and Chromium (CR) wear debris from the bearing. This study compares whole blood metal ion levels from patients drawn at one-year following Birmingham Hip Resurfacing (BHR) to levels taken at a minimum 10-year follow-up. A retrospective chart review was conducted to identify all patients who underwent a BHR for osteoarthritis with a minimum 10-year follow-up. Whole blood metal ion levels were drawn at final follow-up in June 2019. These results were compared to values from patients with one-year metal ion levels. Of the 211 patients who received a BHR, 71 patients (54 males and 17 females) had long term metal ion levels assessed (mean follow-up 12.7 +/− 1.4 years). The mean Co and Cr levels for patients with unilateral BHRs (43 males and 13 females) were 3.12 ± 6.31 ug/L and 2.62 ± 2.69 ug/L, respectively, and 2.78 ± 1.02 ug/L and 1.83 ± 0.65 ug/L for patients with bilateral BHRs (11 males and 4 females). Thirty-five patients (27 male and 8 female) had metal-ion levels tested at one-year postoperatively. The mean changes in Co and Cr levels were 2.29 ug/l (p = 0.0919) and 0.57 (p = 0.1612), respectively, at one year compared to long-term. These changes were not statistically significant. This study reveals that whole blood metal ion levels do not change significantly when comparing one-year and ten-year Co and Cr levels. These ion levels appear to reach a steady state at one year. Our results also suggest that regular metal-ion testing as per current Medicines and Healthcare products Regulatory Agency (MHRA) guidelines may be impractical for asymptomatic patients. Metal-ion levels, in and of themselves, may in fact possess little utility in determining the risk of failure and should be paired with radiographic and clinical findings to determine the need for revision


Aims. To establish the survivorship, function, and metal ion levels in an unselected series of metal-on-metal hip resurfacing arthroplasties (HRAs) performed by a non-designer surgeon. Methods. We reviewed 105 consecutive HRAs in 83 patients, performed by a single surgeon, at a mean follow-up of 14.9 years (9.3 to 19.1). The cohort included 45 male and 38 female patients, with a mean age of 49.5 years (SD 12.5). Results. At the time of review 13 patients with 15 hips had died from causes unrelated to the hip operation, and 14 hips had undergone revision surgery, giving an overall survival rate of rate of 86.7% (95% confidence interval (CI) 84.2 to 89.1). The survival rate in men was 97.7% (95% CI 96.3 to 98.9) and in women was 73.4% (95% CI 70.6 to 75.1). The median head size of the failed group was 42 mm (interquartile range (IQR) 42 to 44), and in the surviving group was 50 mm (IQR 46 to 50). In all, 13 of the 14 revised hips had a femoral component measuring ≤ 46 mm. The mean blood levels of cobalt and chromium ions were 26.6 nmol/l (SD 24.5) and 30.6 nmol/l (SD 15.3), respectively. No metal ion levels exceeded the safe limit. The mean Oxford Hip Score was 41.5 (SD 8.9) and Harris Hip Score was 89.9 (14.8). In the surviving group, four patients had radiolucent lines around the stem of the femoral component, and one had lysis around the acetabular component; eight hips demonstrated heterotopic ossification. Conclusion. Our results confirm the existing understanding that HRA provides good long-term survival and function in patients with adequate-sized femoral heads. This is evidenced by a 97.7% survival rate among men (larger heads) in our series at a mean follow-up of 14.9 years. Failure is closely related to head sizes ≤ 46 cm. Cite this article: Bone Jt Open 2022;3(1):68–76


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 69 - 69
1 Jan 2017
Van Der Straeten C Banica T De Smet A Van Onsem S Sys G
Full Access

Systemic metal ion monitoring (Co;Cr) has proven to be a useful screening tool for implant performance to detect failure at an early stage in metal-on-metal hip arthroplasty. Several clinical studies have reported elevated metal ion levels after total knee arthroplasty (TKA), with fairly high levels associated with rotating hinge knees (RHK) and megaprostheses. 1. In a knee simulator study, Kretzer. 2. , demonstrated volumetric wear and corrosion of metallic surfaces. However, prospective in vivo data are scarce, resulting in a lack of knowledge of how levels evolve over time. The goal of this study was to measure serum Co and Cr levels in several types TKA patients prospectively, evaluate the evolution in time and investigate whether elevated levels could be used as an indicator for implant failure. The study was conducted at Ghent University hospital. 130 patients undergoing knee arthroplasty were included in the study, 35 patients were lost due to logistic problems. 95 patients with 124 knee prostheses had received either a TKA (primary or revision) (69 in 55 patients), a unicompartimental knee arthroplasty (7 UKA), a RHK (revision −7 in 6 patients) or a megaprosthesis (malignant bone tumours − 28 in 27 patients). The TKA, UKA and RHK groups were followed prospectively, with serum Co and Cr ions measured preoperatively, at 3,6 and 12 months postoperatively. In patients with a megaprosthesis, metal ions were measured at follow-up (cross-sectional study design). In primary knees, we did not observe an increase in serum metal ion levels at 3, 6 or 12 months. Two patients with a hip arthroplasty had elevated preTKA Co and Cr levels. There was no difference between unilateral and bilateral knee prostheses. In the revision group, elevated pre-revision levels were found in 2 failures for implant loosening. In both cases, ion levels decreased postoperatively. In revisions with a standard TKA, there was no significant increase in metal ions compared to primary knee arthroplasty. RHK were associated with a significant increase in Co levels even at short-term (3–12 months). The megaprosthesis group had the highest metal ion levels and showed a significant increase in Co and Cr with time in patients followed prospectively. With the current data, we could not demonstrate a correlation between metal ion levels, size of the implant or length of time in situ. In primary knee arthroplasty with a standard TKA or UKA, metal ion levels were not elevated till one year postoperatively. This suggests a different mechanism of metal ion release in comparison to metal-on-metal hip arthroplasties. In two cases of revision for implant loosening, pre-revision levels were elevated, possibly associated with component wear, and decreased after revision. With RHK, slightly elevated ion levels were found prospectively. Megaprostheses had significantly elevated Co and Cr levels, due to corrosion of large metallic surfaces and/or wear of components which were not perfectly aligned during difficult reconstruction after tumour resection. Further research is needed to assess the clinical relevance of metal ion levels in knee arthroplasty


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 63 - 63
1 Mar 2017
Van Der Straeten C Banica T De Smet A Van Onsem S Sys G
Full Access

Introduction. Systemic metal ion monitoring (Co;Cr) has proven to be a useful screening tool for implant performance to detect failure at an early stage in metal-on-metal hip arthroplasty. Several clinical studies have reported elevated metal ion levels after total knee arthroplasty (TKA), with fairly high levels associated with rotating hinge knees (RHK) and megaprostheses. 1. In a knee simulator study, Kretzer. 2. , demonstrated volumetric wear and corrosion of metallic surfaces. However, prospective in vivo data are scarce, resulting in a lack of knowledge of how levels evolve over time. The goal of this study was to measure serum Co and Cr levels in several types TKA patients prospectively, evaluate the evolution in time and investigate whether elevated levels could be used as an indicator for implant failure. Patients and Methods. The study was conducted at Ghent University hospital. 130 patients undergoing knee arthroplasty were included in the study, 35 patients were lost due to logistic problems. 95 patients with 124 knee prostheses had received either a TKA (primary or revision) (69 in 55 patients), a unicompartimental knee arthroplasty (7 UKA), a RHK (revision −7 in 6 patients) or a megaprosthesis (malignant bone tumours − 28 in 27 patients) (Fig 1). The TKA, UKA and RHK groups were followed prospectively, with serum Co and Cr ions measured preoperatively, at 3,6 and 12 months postoperatively. In patients with a megaprosthesis, metal ions were measured at follow-up (cross-sectional study design). Results (Fig 2 and 3). In primary knees, we did not observe an increase in serum metal ion levels at 3, 6 or 12 months. Two patients with a hip arthroplasty had elevated preTKA Co and Cr levels. There was no difference between unilateral and bilateral knee prostheses. In the revision group, elevated pre-revision levels were found in 2 failures for implant loosening. In both cases, ion levels decreased postoperatively. In revisions with a standard TKA, there was no significant increase in metal ions compared to primary knee arthroplasty. RHK were associated with a significant increase in Co levels even at short-term (3–12 months). The megaprosthesis group had the highest metal ion levels and showed a significant increase in Co and Cr with time in patients followed prospectively. With the current data, we could not demonstrate a correlation between metal ion levels, size of the implant or length of time in situ. Discussion. In primary knee arthroplasty with a standard TKA or UKA, metal ion levels were not elevated till one year postoperatively. This suggests a different mechanism of metal ion release in comparison to metal-on-metal hip arthroplasties. In two cases of revision for implant loosening, pre-revision levels were elevated, possibly associated with component wear, and decreased after revision. With RHK, slightly elevated ion levels were found prospectively. Megaprostheses had significantly elevated Co and Cr levels, due to corrosion of large metallic surfaces and/or wear of components which were not perfectly aligned during difficult reconstruction after tumour resection. Further research is needed to assess the clinical relevance of metal ion levels in knee arthroplasty. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 21 - 21
1 Nov 2021
DeBenedetti A Della Valle CJ Jacobs JJ Nam D
Full Access

The purpose of this randomized controlled trial was to evaluate serum metal ion levels in patients undergoing THA with either a standard or modular dual-mobility bearing. Patients undergoing primary THA for osteoarthritis were randomized to receive either a modular dual-mobility or a standard polyethylene bearing. All patients received the same titanium acetabular and femoral component and a ceramic femoral head. Only patients without a prior history of metal implants in their body were eligible for inclusion, thus isolating serum metal ions to the prosthesis itself. Serum metal ion levels were drawn pre-operatively and at 1 year postoperatively. Power analysis determined that 40 patients (20 in each group) were needed to identify a clinically relevant difference in serum cobalt of 0.35 ng/ml (ppb) at 90% power assuming a pooled standard deviation of 0.31 ppb and alpha=0.05; an additional 30% were enrolled to account for potential dropouts. 53 patients were enrolled, with 22 patients in the modular dual-mobility group and 20 in the standard cohort with data available at one-year. No differences in the serum cobalt (0.17 ppb [range 0.07 to 0.50] vs. 0.19 ppb [range 0.07 to 0.62], p = 0.51) or chromium levels (0.19 ppb [range 0.05 to 0.56] vs. 0.16 ppb [range 0.05 to 0.61], p = 0.23) were identified. At 1 year postoperatively, no differences in serum cobalt or chromium levels were identified with this design of a modular dual mobility bearing when compared to a standard polyethylene bearing


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 61 - 61
1 Aug 2013
van der Jagt D Mokete L Nwokeyi K Schepers A
Full Access

Metal ion levels are used to track the performance of metal containing bearings in hip replacement patients. Changes in whole blood metal ion levels are indicators of wear rates in these bearings. Normal metal ion levels are variable, and range widely. Changes in these “non-bearing” levels over a period of time may influence the monitoring of these bearings. Methods. As part of a prospective randomised trial of different bearing surfaces, whole blood metal ion levels were monitored. This included four cohorts of patients, namely ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC) and ceramic-on-metal (CoM). Serial whole blood metal ion levels in the non-metal bearings, namely CoC and CoP, were analyzed. Results. There was no consistency in these whole blood metal ion levels. Intra-patient variations in these levels over a period of time could not be due to bearing-produced metal ions as these were all metal free, and thus not the source of any endogenous ions. These intra-patient variations may reflect changes in exogenous exposure to these metal ions, fluctuations in these patient's metabolic functions or production of metal ions from non-bearing prosthetic sources. Conclusion. This finding of variations of “normal” intra-patient whole blood metal ions highlights the importance of determining a patient's average baseline levels, particularly when these are used to determine changes in these levels when part of a protocol to monitor the performance of metal containing hip replacement bearings


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims. Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon. Methods. A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records. Results. A total of 243 hips (205 patients (163 male, 80 female; mean age at surgery 55.3 years (range 25.7 to 75.3)) with MoM-HRA performed between April 2003 and October 2020 were included. Mean follow-up was 11.2 years (range 0.3 to 17.8). Osteoarthritis was the most common indication (93.8%), and 13 hips (5.3%; 7M:6F) showed dysplasia (lateral centre-edge angle < 25°). Acetabular cups were implanted at a median of 45.4° abduction (interquartile range 41.9° - 48.3°) and stems neutral or valgus to the native neck-shaft angle. In all, 11 hips (4.5%; one male, ten females) in ten patients underwent revision surgery at a mean of 7.4 years (range 2.8 to 14.2), giving a cumulative survival rate of 94.8% (95% confidence interval (CI) 91.6% to 98.0%) at ten years, and 93.4% (95% CI 89.3% to 97.6%) at 17 years. For aseptic revision, male survivorship was 100% at 17 years, and 89.6% (95% CI 83.1% to 96.7%) at ten and 17 years for females. Increased metal ion levels were implicated in 50% of female revisions, with the remaining being revised for unexplained pain or avascular necrosis. Conclusion. The Birmingham MoM-HR showed 100% survivorship in males, exceeding the National Institute for Health and Care Excellence ‘5% at ten years’ threshold. Female sex and small component sizes are independent risk factors. Dysplasia alone is not a contraindication to resurfacing. Cite this article: Bone Jt Open 2023;4(11):853–858


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 96 - 96
1 Mar 2008
Kim P Dunbar M Laflamme Y Conway A Hrushowy H
Full Access

This study evaluates metal ion levels in patients enrolled in a prospective evaluation of hip resurfacing arthroplasty utilizing the Conserve Plus implant (Wright Medical Technology). Serum, urine and erythrocyte metal ion levels were assessed preoperatively and postoperatively. Average levels at three months were 24 nmol/l for cobalt and 40 nmol/l for chromium. These increased to 40 nmol/l for cobalt and 80 nmol/l for chromium at the six-month mark. The clinical significance of increased metal ion levels is yet to be determined. To evaluate the clinical, functional and radiographic outcome of hip resurfacing arthroplasty utilizing the Conserve Plus implant (Wright Medical Technology). Serum, urine and erythrocyte metal ion levels were evaluated both pre and postoperatively. Ion levels for both cobalt and chromium increased from the three-month to the six-month mark postoperatively and were significantly elevated relative to preoperative values. This study helps to establish a baseline for metal ion levels following hip resurfacing arthroplasty. Serum, urine and erythrocyte metal ion levels were assessed preoperatively and postoperatively. All levels were within normal range preoperatively. Average serum levels at three months were 24 nmol/l for cobalt and 40 nmol/l for chromium. These increased to 40 nmol/l for cobalt and 80 nmol/l for chromium at the six-month mark. Average erythrocyte metal ion levels at three months were 0.92 ug/l for cobalt and 1.8 ug/l for chromium. The average erythrocyte levels at six months were 1.3 ug/l for cobalt and 2.0 ug/l for chromium. A prospective multi-center study to evaluate the outcome of hip resurfacing arthroplasty was initiated in July 2003. Each patient was evaluated preoperatively and postoperatively with outcome scores, radiographs as well as serum, urine and erythrocyte metal ion levels. The results of this prospective evaluation show a rise in ion levels from three to six months postoperatively. Further follow-up is necessary to assess future trends with respect to the ion levels as well as the clinical significance. Funding: This study has been sponsored in part by Wright Medical Technology


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 365 - 371
1 Apr 2019
Nam D Salih R Nahhas CR Barrack RL Nunley RM

Aims. Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell (vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown improved stability in patients deemed ‘high-risk’ for dislocation undergoing total hip arthroplasty (THA), their performance in young, active patients has not been reported. This study’s purpose was to assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular DM acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design. Patients and Methods. This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m. 2. and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. A total of 43 patients (30 male, 13 female; mean age 52.6 years (. sd. 6.5)) were enrolled. All patients had a minimum of two years’ clinical follow-up. Patient-reported outcome measures, whole blood metal ion levels (ug/l), and periprosthetic femoral BMD were measured at baseline, as well as at one and two years postoperatively. Power analysis indicated 40 patients necessary to demonstrate a five-fold increase in cobalt levels from baseline (alpha = 0.05, beta = 0.80). A mixed model with repeated measures was used for statistical analysis. Results. Mean Harris Hip Scores improved from 54.1 (. sd. 20.5) to 91.2 (. sd. 10.8) at two years postoperatively (p < 0.001). All patients had radiologically well-fixed components, no patients experienced any instability, and no patients required any further intervention. Mean cobalt levels increased from 0.065 ug/l (. sd. 0.03) preoperatively to 0.30 ug/l (. sd. 0.51) at one year postoperatively (p = 0.01) but decreased at two years postoperatively to 0.16 ug/l (. sd. 0.23; p = 0.2). Four patients (9.3%) had a cobalt level outside the reference range (0.03 ug/l to 0.29 ug/l) at two years postoperatively, with values from 0.32 ug/l to 0.94 ug/l. The mean femoral BMD ratio was maintained in Gruen zones 2 to 7 at both one and two years postoperatively using this stem design. At two years postoperatively, mean BMD in the medial calcar was 101.5% of the baseline value. Conclusion. Use of a modular DM prosthesis and cementless, tapered femoral stem has shown encouraging results in young, active patients undergoing primary THA. Elevation in mean cobalt levels and the presence of four patients outside the reference range at two years postoperatively demonstrates the necessity of continued surveillance in this cohort. Cite this article: Bone Joint J 2019;101-B:365–371


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 52 - 52
1 Jun 2017
Pradhan R Grammatopoulos G Wilson H Asopa V Andrade T
Full Access

A modular hemiarthroplasty has a Metal-on-Metal (MoM) taper-trunnion junction, which may lead to increased wear and Adverse-Reaction-to-Metal-Debris (ARMD). To-date no wear related issues have been described in the elderly and less active that receives a hemiarthroplasty. This study aims to determine in vivo wear (i.e. serum metal ion levels) in hip hemiarthroplasty, and identify factors associated with increased wear. This is a prospective, IRB approved, single-centre, cohort study of patients that received an uncemented, modular hemiarthroplasty of proven design for the treatment of hip fracture between 2013–2015. All, alive, patients at 12-months post-implantation with AMTS≥6 were invited to participate. Of the 125 eligible patients, 50 accepted the invitation and were reviewed, including clinical/radiological assessment, metal-ion ([Chromium (Cr) and Cobalt (Co)]) measurement and Oxford Hip Score (OHS). Acetabular erosion was graded (0–3: normal-protrusio). Metal ion levels were considered high if ≥7ppb. The mean OHS was 37 (SD: 10). No acetabular erosion was detected in 21, whilst the remaining had either grade-1 (n=21) or grade-2 (n=8). The median Cr and Co levels were 2.9 (SD:9) and 2.2 (SD:4) respectively. There were 8 cases (16%) with high ion levels. To-date only 2 of them has an ARMD lesion, and none have been revised. Patients with metal ion levels had similar pre-fall mobility, taper- and head- size and OHS to those with low metal ion levels (p=0.2–0.7) However, all hips with high metal ion levels had evidence of acetabular erosion (≥1). Modular Hip hemiarthroplasties and their taper-trunnion junction are not immune to high wear and ARMD despite being implanted in a less active cohort. Acetabular erosion should alert clinicians, as it is associated with 20× increased-risk of taper wear, presumably due to the increased transmitted torque. Whether the use of modular hemiarthroplasties should remain is debatable


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 141 - 141
1 May 2016
Frisch N Wessell N Van Holsbeeck M Silverton C
Full Access

Introduction. The use of metal-on-metal (MOM) and modular total hip arthroplasty (THA) is associated with potentially serious complications including elevated serum metal ion levels, pseudotumor, cardiomyopathy and neurologic abnormalities. The primary aim of this analysis was to identify any associations between the presence of pseudotumor, serum metal ion levels, and specific dual modular implant components. Methods. We evaluated prospectively collected data from 49 patients, mean age 58.4 years, who underwent implantation of modular THA from 01/2004-01/2010. The collected data spanned a 5–11 year period from the time of index procedure. Serum metal ion levels, including titanium, cobalt and chromium, were collected in 2012 and 2015. Hip ultrasounds were performed on each patient by a trained musculoskeletal radiologist for evaluation of the presence of soft-tissue pseudotumor. Univariate nonparametric tests were used to compare the two groups: Fisher's exact tests for categorical variables, and Wilcoxon two-group tests for continuous variables. For the purposes of analysis, values that were below the level of detection (LOD) were set to half the LOD. All analyses were performed using SAS 9.4 (SAS Institute Inc, Cary, NC, USA). Statistical significance is set at p<0.05. Results. Eight of 49 patients (16.3%) had pseudotumors on ultrasound examination. The average size measured 35.05 cm3 (7.35 cm3 – 130.81 cm3). In patients without pseudotumor, the serum levels (ng/mL) of titanium, cobalt and chromium were 3.2 ± 2.7, 4.4 ± 5.7 and 3.4 ± 4.9 in 2012 and 3.6 ± 4.9, 11.3 ± 33.7 and 5.3 ± 10.8 in 2015, respectively. Patients with pseudotumor had titanium, cobalt and chromium levels of 3.5 ± 2.3, 8.4 ± 8.7 and 6.2 ± 9.4 in 2012 and 4.1 ± 3.4, 6.0 ± 4.5 and 5.1 ± 6.4 in 2015. The ratio of cobalt to chromium was 1.6 ± 1.3 in 2012 and 1.8 ± 1.2 in 2015 in patients without pseudotumor and 2.1 ± 1.2 and 1.9 ± 1.3 with patients with pseudotumor, respectively. There was no statistical correlation between the presence of pseudotumor and age, component pairings (stem, neck and cup) and any of the serum metal ion levels. Discussion/Conclusion. In this prospective cohort study the incidence of pseudotumor was 16.3% in asymptomatic patients with modular THA. The presence of pseudotumor did not correlate with component pairings, serum metal ion levels or cobalt to chromium ratios


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_3 | Pages 8 - 8
1 Apr 2019
Kiran M Oikonomidis L AlMutani M Armstrong C Kumar G Peter V
Full Access

Background. Modularity in total hip replacement(THR) enables precise recreation of native hip biomechanics. However, there have been concerns about raised metal ion levels with increased number of interfaces. We present the 3 year results of ML taper with Kinectiv technology(MLKT), a modular neck uncemented stem. This system has modular neck options, but has only one [0] head in various diameters. Methods. 97 hips in 97 patients with a MLKT stem and Continuum socket were included in this prospective study. Harris hip score, Oxford hip scores (HHS and OHS) and yearly blood Cobalt(Co), Chromium(Cr) and Titanium(Ti) were recorded. The primary end point was revision for any reason. Paired t- test was used to assess improvement in functional scores. Results. The mean age was 62.1±8.7 years. The mean follow-up was 3.75±0.67years. The mean HHS improved from 45.8±5.1 to 92.6±3.1(p<0.001) and the mean OHS improved form 17.59±4.71 to 43.1±2.2(p<0.001). One hip was revised for deep infection at 2.6 years. The mean Co, Cr and Ti levels at 3 years were 18.45,19.62 and 36.47 nmol/l respectively. The survivorship of the cohort at a minimum follow-up of 3 years was 98.7%. Conclusion. Our study suggests that despite the presence of an additional interface between the neck and the stem, the MLKT stem does not result in increased metal ion levels or higher failure rate. This is a prospective and consecutive series of patients with complete radiological and functional follow-up. The MLKT stem has good functional results with no concerns about raised metal ion levels in the short term


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 149 - 149
1 Jul 2014
Slagis S Skrepnik N Wild J Robertson M Nielsen B Skrepnik T Eberle R
Full Access

Summary. Management of metal on metal hip replacements can be accomplished with a simple algorithm including easily available metal ion levels and hip MRI with metal artifact reducing software. After revision serum metal ion levels can be expected to fall rapidly. Introduction. Metallic ion release may be related to bearing surface wear and thus serves as an indicator of the in-vivo performance of metal on metal articulations. The purpose of this prospective, controlled study was to compare new large head metal on metal hip components with established modular metal on metal and metal on polyethylene and to determine their effects on serum metal levels before and after revision. Patients & Methods. We performed a multi-surgeon, prospective, controlled trial to compare clinical, radiographic, and metal ion concentration in serum (cobalt and chrome) results across multiple devices including the Large Head ASR XL System (MoM-1), the Ultamet Advanced Modularity System (MoM-2), and as the control the Pinacle Acetabular Cup System with polyethylene liner (MoP). One hundred and fifty-one consecutive patients undergoing THA were enrolled in the study: MoM-1 n=97; MoM-2 n=22; MoP n=32. Clinical, radiographic, and venous blood assessments were performed pre-operatively, and post-operatively at 6 months, 1 year and 2 years, and after revision (1,3,6,12 months). All serum ion concentrations are reported in nmol/L. We are following metal ion levels after revision and have developed an algorithm to diagnose and manage patients with MoM THA. Results. MoM-1 patients had significantly increased average cobalt and chromium levels. Clinical scores improved after surgery in all groups and continued to improve in MoM-2 and MoP patients after 2 years but decreased slightly in the MoM-1 patients at 2 years. Average cup inclination angle did not differ significantly between the groups: MoM-1 50.2, MoM-2 47.8, and MoP 51.7. In the MoM-1 group 11 patients (11%) had significantly elevated ion levels (MoM-1 Outliers). Nine hips (9.3%) in 8 MoM-1 outlier patients required revision. Metal ion levels were not significantly different between MoM-2 and MoP groups. Metal ion levels after revision in the MoM-1 group decreased rapidly but at one year post-operatively have still not returned to an equivalent baseline comparable to the MoM-2 and MoP groups. All revisions were in the MoM-1 group. Chromium levels decreased more slowly than Cobalt levels. Discussion. To our knowledge this is the only data in the literature prospectively comparing ion levels among groups and reporting post revision ion levels. Average serum ion levels were elevated at all post-operative samples in the MoM-1 group but this was due to significantly elevated levels in a subset of outliers who required revision. Excluding the outliers there is not a significant difference in post-operative ion levels between the groups. There was no radiographic evidence of component malposition or aseptic loosening in any of the groups. Control groups (MoM-2, MoP) performed comparatively across all variables. We present an algorithm to diagnose and manage patients with metal on metal THA and offer evidence that metal ion levels do decrease after revision but still remain abnormally elevated at one-year post revision compared to the control group. A significant portion of MoM-1 performs comparatively to the controls in terms of ions


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 201 - 201
1 Dec 2013
Watanabe H Hachiya Y Murata H Muramatsu K Taniguchi S Kondo M Tanaka K
Full Access

Introduction. Higher concentrations of metal ion levels after Metal-on-metal (MoM) THA are a cause for concern. Elevated cobalt (Co) and chromium (Cr) ion levels in the blood indicate metal wear, and may predict secondary soft-tissue damage (adverse reaction to metal debris; ARMD). Although, it is well known that concentrations of metal ion levels are elevated in the short term after MoM, the long-term consequences in ion concentration and risk factors for increased ion levels are not clarified. We sequentially investigated the postoperative Co and Cr ion levels after MoM THA and the relationship between the metal ion levels and several risk factors. Materials and Methods. We reviewed the data on one hundred and eighty six patients of two hundred ninety one MoM THA cases. The one hundred eighty six patients were measured at least three times after a MoM THA surgery over a five year (2005–2010) period in our institution. Serum cobalt and chromium levels were measured by inductor coupled plasma – mass spectrometry at several times in follow-up period, (measured at the preoperative period, the third month, the sixth month, the first year, the second year, and the fourth year after MoM THA). Furthermore, we investigated the correlation between the metal ion levels and various factors which might influence the release of metal ions, such as Body mass index (BMI), renal function, femoral head size, unilateral or bilateral THA, the cup position, and postoperative activity. The renal function was evaluated by measuring estimated glomerular filtration ratio (GFR) at preoperative examination. A postoperative activity was assessed with a pedometer measurement counting number of steps a day. A cup position was evaluated by lateral inclination measured by X-ray or computed tomography. Results. Average serum Co and Cr concentrations in preoperative period were 0.69 and 0.05 mg/ ml, respectively. Postoperative serum Co and Cr ion levels were significantly increased compared with preoperative value throughout the postoperative period. There was no significant correlation with regards to BMI, renal function, femoral head size tothe metal ion level measurement. In bilateral THA cases, Co and Cr ion concentrations were significantly increased compared with unilateral THA cases. In addition, in cases that its cup inclination was more than 50 degrees, Co and Cr ion concentration were significantly increased compared with cases less than 50 degrees in the first year after surgery. There was a trend for higher metal ion levels in the group of patients who walked more than 7000 steps a day, but this did not reach statistical significance. Conclusion. Metal ion concentrations of almost patients were increased after MoM THA surgery. Side effects related to elevation of serum Co or Cr concentration were currently not identified and overall clinical results were good. However, Longer follow-up would be necessary if the patients have overlapping risk factors, because those patients may experience elevation of the level in postoperative late stage


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 55 - 55
1 May 2012
Mellon SJ Kwon Y Simpson DJ Murray DW Gill HS
Full Access

Introduction. Metal-on-metal (MoM) hip resurfacing arthroplasty is a popular choice for young and active patients. However, there are concerns recently regarding soft tissue masses or pseudotumours. The appearance of these complications is thought to be related blood metal ion levels. The level of metal ions in blood is thought to be the result of MoM wear. In the present study the contribution of acetabulum orientation to stress distribution was investigated. Methods. Four subjects with MoM resurfacings and with known blood metal ion levels underwent motion analysis followed by CT scans. The positions of the acetabular (cup) and femoral components were determined the CT data relative to local coordinate systems in the pelvis (PCS) and the femur (FCS). Transformations, calculated from the motion analysis data, between the PCS and FCS gave the position of the cup relative to the femoral component for each frame of captured motion data. Hip reaction forces were taken from published data1. The intersection of hip reaction force with each subject's cup and the increase in inclination required to move the force to the edge of the cup was calculated for 2% intervals during the stance phase of gait. Finite element models representing each subject's cup and femoral components were created and contact stresses were determined for the native cup inclination angle. For each model, the effect of increasing the inclination of the cup, by up to 10°, in 1° increments, was determined. Results and Discussion. The two subjects with high metal ion levels had inclination angles of 60.2° and 53.7° whereas the two with low metal ion levels had inclination angles of 45.6° and 46.5°. The subjects with high metal ion levels required very little increase to their inclination angle to cause the hip reaction force vector to intersect at the edge. The contact stress on the cup increased dramatically when the inclination angle was such that the hip reaction force intersected with the edge. The average increase in contact stress under edge-loading conditions was 57% for the two subjects with high metal ions. In contrast, the subjects with low metal ions exhibited no change in contact stress when the inclination angle of their cups was increased by 10°. The inter-subject variability in the measured hip reaction forces was greater than the amount of increase in cup inclination required to induce edge-loading for the subjects with high metal ion levels. These results suggest that poor positioning of the cup during surgery may result in edge-loading, a greater rate of wear and adverse biological reactions associated with metal ion release


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 63 - 63
1 Apr 2018
Shon W Han S Lee D Kim H
Full Access

Background. Recent clinical studies have suggested that systemic metal ion levels are significantly elevated at midterm follow-up after ceramic-on-metal (COM) bearing. However, it is not clear whether there is a correlation between patient- and surgical-related factors including the lifestyle and elevated levels of serum metal ions following COM total hip arthroplsty (THA). Material and Methods. Two hundred and one patients (234 hips) including 121 COM patients (140 hips) and 80 non-COM patients (94 hips) were enrolled in accordance with the inclusion criteria. The patients were divided into three groups based on the type of surgical bearings used. The Harris Hip Score (HHS), University of California, Los Angeles (UCLA) activity scale score, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score were measured, and radiographs were obtained for the analysis. Serum metal ion levels of cobalt and chromium were measured using a high-resolution inductively coupled plasma mass spectrometry. Patient- and surgical-related factors were analyzed to determine which group of patients is at a high risk of metal ion-related problems. Results. Significantly higher serum levels of Co and Cr were detected in the serum of the COM THA group (Co: 1.86±4.0 µg/L, range: 0.30 to 34.20 µg/L; Cr: 1.81±2.87 µg/L, range: 0.10 to 27.80 µg/L) than in the serum of the non-COM THA group (Co: 0.27±0.14 µg/L, range: 0.15 to 0.90 µg/L; Cr: 0.19±0.25 µg/L, range; 0.10 to 2.30 µg/L) (p<0.001). The HHS in the COM group was significantly better than that in the non-COM group (p=0.013). The total ROM of the THAs was significantly greater in the 36-mm COM THA group (272.7°, range: 200°–345°) than in the non-COM group (248.5°, range: 135°–300°) (p<0.001). No radiolucency, osteolysis, or loosening was found during the follow-up radiographic examination. The serum Co levels of patients who achieved the squatting position were significantly higher than those of patients who could not squat (Co: p=0.033; Cr: p=0.074). The serum Co and Cr levels of patients who achieved the kneeling position were significantly higher than those of patients who could not kneel (Co: p=0.049; Cr: p=0.031). There was no significant difference between the two groups in the cross-legged sitting position. The metal ion levels of the COM THA group correlated with the total ROM (Co: p=0.0293; Cr: p=0.0399), and those of the patients who were capable of squatting and kneeling were significantly higher than those of the patients who were unable (p<0.05). However, age, BMI, acetabular cup position and patient activity did not show significant correlations with the serum metal ion levels. Conclusions. Patients who underwent a 36-mm COM THA had good clinical outcomes with an excellent hip function at the short and midterm follow-up intervals. However, high levels of metal ions were detected in the serum of COM THA patients. We found that COM THA patients who were capable of greater ROMs, squatting, and kneeling are at risk of metal ion-related problems


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 422 - 422
1 Dec 2013
Meftah M Noble P Incavo SJ
Full Access

Background:. The Rejuvenate modular neck stem (Stryker, Mahwah, NJ) was recently recalled due to corrosion at the neck-stem junction. The purpose of this study was to investigate the rate of corrosion related failures and survivorship of this implant, and analyze the correlation between the implant and patient factors with serum metal ion levels. Material and Methods:. Between June 2009 and July 2012, 123 Rejuvenate stems (97 modular and 26 non-modular) THAs were implanted in 104 patients by a single surgeon via a modified anterolateral approach. Serum Cobalt (Co) and Chromium (Cr) levels (microgram per liter [μg/L]) were obtained in all patients. In cases of elevated serum metal ion levels or symptomatic hip, patients underwent magnetic resonance imaging (MRI) for assessment of osteolysis or adverse local tissue reactions (ALTR). Correlation between implant factors (implant size, head size, head length, offset), patient factors (age, gender, BMI) with serum metal ion levels and revisions were analyzed using logistic regression models. Results:. The mean follow-up was 2.7 ± 0.6 years. The mean Co and Cr levels were 5.4 ± 5.7 μg/L (0.2–31) and 2.1 ± 1.5 μg/L (0.1–4.3), respectively. The differences between the Co and Cr levels in the two groups were statistically significant. 49% of THAs in the modular group had elevated metal ion levels (> 4.0 μg/L). There was a significant correlation between higher metal ion levels, younger age, and higher offset (p < 0.05). Presence of pain and high cobalt levels were significant predictors for revision surgery. The rate of revision at the time of this study was 26%, the majority were in the 2. nd. year after surgery. The Kaplan-Meier survivorship was 75% at the time of this study. Discussion and Conclusions:. The short-term high rate of corrosion related revision with Rejuvenate modular neck stems is extremely alarming. We anticipate more revisions in the near future. Level of Evidence: Level III, Therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence