In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures. This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival.Aims
Methods
Introduction.
Aims. The aims of this study were to evaluate the incidence of reoperation (all cause and specifically for periprosthetic femoral fracture (PFF)) and mortality, and associated risk factors, following a hemiarthroplasty incorporating a cemented collarless polished taper slip stem (PTS) for management of an
Aims: To explore potential predictors of functional outcome one year after the injury in elderly women who sustained a displaced
Evidence suggests as little as 32percnt; of those with a displaced
Current evidence suggests that we should be moving away from Thompson's hemiarthroplasties for patients with
This paper describes the methods applied to assess the cost-effectiveness of cemented versus uncemented hemiarthroplasty among hip fracture patients in the World Hip Trauma Evaluation Five (WHiTE5) trial. A within-trial cost-utility analysis (CUA) will be conducted at four months postinjury from a health system (National Health Service and personal social services) perspective. Resource use pertaining to healthcare utilization (i.e. inpatient care, physiotherapy, social care, and home adaptations), and utility measures (quality-adjusted life years) will be collected at one and four months (primary outcome endpoint) postinjury; only treatment of complications will be captured at 12 months. Sensitivity analysis will be conducted to assess the robustness of the results.Aim
Methods
Intracapsular fractures of the femoral neck in young adults are a surgical emergency. Recent literature reviews have questioned whether the timing of surgery reduces the incidence of avascular necrosis, non-union and revision. A study was performed to determine how many patients met a 12-hour target for operative fixation with this injury. Possible sources of delay to theatre were reviewed. A Fractures Outcomes Research Database was used to identify patients aged 18–64 who were admitted to the Royal Victoria Hospital in Belfast between 1st Jan 2008 and 31st Dec 2009. Intracapsular fractures of the femoral neck which were treated with a 2-hole dynamic hip screw were included. Time of injury, time of presentation in A&E, time of admission to fracture ward, operation time, demographic data, and the mechanism of injury were extracted from the database.Introduction
Methods
The aim of this retrospective study was to evaluate the failure rate among different fixation devices for undisplaced fracture neck of femur. All 52 patients with Garden I and II hip fractures who underwent surgery in a teaching hospital in London from January 2007 to June 2012 were included. Electronic patient records were accessed to collect the patient data. There were 52% females and the mean age of patients was 70 years. Thirty patients had cannulated screws, 18 – dynamic hip screw (DHS) with de-rotation screw and 4 had DHS alone. Initial results showed that 36% patients had re-operation. 7(77%) had total hip replacement and 1(11%) had metal work removal. The reason for revision was failure of fixation in 8 (88%) and avascular necrosis in 1 (11%). There was significantly higher failure rate in the DHS with derotation screw group (50%) compared to the cannulated screw group (35%) and the DHS alone group (0%). Average time to planned revision was 11.1 months. Traditionally undisplaced intra capsular hip fractures are treated by in-situ fixation using different devices. Biomechanically DHS with de-rotation screw achieves better rotational and axial stability compared to other fixation devices. However, our study showed a higher failure rate in this group. Inability to achieve a perfectly parallel screw position seems to be a significant factor responsible for high failure. Higher failure rates with fixation may boost the role of replacement arthroplasty as one off surgical treatment in elderly patients.
In Displaced Intracapsular Hip Fractures (ICHF) in young active patients, preservation of the femoral head and its blood supply are of high importance and urgent surgical treatment with anatomic reduction and internal fixation is the preferred intervention. Due to the strong varus displacement shear forces exerted across the hip, there are relatively high complication rates after fixation. There is no consensus regarding the optimal fixation device or technique. This retrospective study compared closed reduction internal fixation method using cannulated cancellous screw (CCS) with the Targon Femoral Neck (TFN) hip fixed angle screw. Data regarding, gender, operational data, duration of surgery, complications, NAS (Numerical Analogue Scale) pain score, Modified Harris Hip Score (MHHS) and SF-12 scores were retrieved for patients younger than 65 with displaced ICHF. Eighty-two patients were included in the study, 30 patients treated with CCS were compared to 52 patients treated with TFN. Fracture configuration (Garden and Pauwel classifications), mean time to surgery and complication rate did not differ significantly. Operative time did differ significantly between groups (CCS 56 minutes, TFN 92 minutes, p<0.001). At final follow-up the CCS group reported less pain (NAS 2.3 vs 3.5, p< 0.049) and better Mental Health Composite score of SF-12 (p=0.017) compared to the TFN group. Complication rates for the treatment of displaced ICHF with TFN and CCS showed no significant differences; however, the functional outcomes, as presented by the NAS and Mental Health Composite score of SF-12, showed superiority for CCS treatment. As this fixation method is related to reduce costs, we suggest CCS for the treatment of displaced ICHF in the young population.
To compare the incidence of Bone Cement Implantation Syndrome (BCIS), perioperative thromboembolic events and mortality in patients with a femoral neck fracture (FNF) treated with a hybrid total hip arthroplasty (THA) without intraoperative unfractioned heparin (UFH) (control) versus a group of patients who received intraoperative UFH before femoral cementation. We retrospectively reviewed 273 patients who underwent hybrid THA due to a FNF between 2015 and 2020. We compared a group of 139 patients without intraoperative administration of UFH (group A) with 134 patients who underwent THA with intraoperative administration of 10 UI/kg UFH (group B). UFH indication was dependent on surgeon´s preference. We assessed the advent of BCIS and 30-day thromboembolic events, as well as 90-day and 1-year mortality. BCIS was observed in 51 cases (18%), defined as Grade 1 (O2% < 94% or fall in systolic blood pressure of 20% to 40%) in 37 cases (13%) and Grade 2 (O2% < 88% or fall in systolic blood pressure of > 40%) in 14 cases (5%). Forty-seven BCIS (35%) were observed in the group that received UFH and 4 BCIS (3%) in the control group (p <0.001). Multivariate regression model showed that intraoperative UFH (OR=18, CI95% 6–52) and consumption of oral anticoagulants (OR=3.3, CI95% 1–10) had an increased risk of developing BCIS. Five patients developed a pulmonary embolism in the UFH group while 2 patients presented this complication in the non UFH group (p=0.231). Mortality was 1% for both groups at 90 days PO (p= 0.98), 2% at 1 year for group A and 3% for group B (p =0.38). BCIS in our series was 18%. We found a paradoxically 17-fold significant increase of BCIS with the use of UFH. Heparin did not prevent BCIS, thromboembolic events and mortality in this group of patients.
NICE Guidelines suggest patients should be offered a Total Hip Replacement (THR) rather than Hemiarthroplasty for a displaced
Aims. Patients receiving cemented hemiarthroplasties after hip fracture have a significant risk of deep surgical site infection (SSI). Standard UK practice to minimize the risk of SSI includes the use of antibiotic-loaded bone cement with no consensus regarding type, dose, or antibiotic content of the cement. This is the protocol for a randomized clinical trial to investigate the clinical and cost-effectiveness of high dose dual antibiotic-loaded cement in comparison to low dose single antibiotic-loaded cement in patients 60 years and over receiving a cemented hemiarthroplasty for an
Intracapsular neck of femur fractures may be treated with fixation or arthroplasty, depending on fracture characteristics and patient factors. Two common methods of fixation are the sliding hip screw, with or without a de-rotation screw, and cannulated screws. Each has its merits, and to date there is controversy around which method is superior, with either method thought to risk avascular necrosis of the femoral head (AVN) rates in the region of 10–20%. Fixation with cannulated screws may be performed in various ways, with current paucity of evidence to show an optimum technique. There are a multitude of factors which are likely to affect patient outcomes: technique, screw configuration, fracture characteristics and patient factors. We present a retrospective case series analysis of 65 patients who underwent cannulated screw fixation of a hip fracture. Electronic operative records were searched from July 2014 until July 2019 for all patients with a neck of femur fracture fixed with cannulated screws: 68 were found. Three patients were excluded on the basis of them having a pathological fracture secondary to malignancy, cases were followed up for 2 years post-operatively. Electronic patient records and X-rays were reviewed for all included patients. All X-rays were examined by each team member twice, with a time interval of two weeks to improve inter-observer reliability. 65 patients were included with 2:1 female to male ratio and average age of 72 years. 36 patients sustained displaced fractures and 29 undisplaced. Ten patients sustained a high-energy injury, none of which developed AVN. Average time to surgery was 40 hours and 57 patients mobilised on day one post-operatively. All cases used either 7 or 7.3mm partially threaded screws in the following configurations: 2 in triangle apex superior, 39 triangle apex inferior, 22 rhomboid and 2 other, with 9 cases using washers. All reductions were performed closed. Five (8%) of our patients were lost to follow-up as they moved out of area, 48 (74%) had no surgical complications, seven (11%) had mild complications, three (5%) moderate and two (3%) developed AVN. Both of these sustained displaced fractures with low mechanism of injury, were female, ASA 2 and both ex-smokers. One received three screws in apex inferior configuration and one rhomboid, neither fixed with washers. Our AVN rate following
Introduction. The National Institute for Health and Care Excellence (NICE) currently recommends the use of total hip replacement (THR) for displaced
Background. Total hip arthroplasty (THA) is increasingly used for active patients with displaced
The February 2013 Trauma Roundup. 360 . looks at: the risk of ankle fractures; absorbable implants; minimally invasive heel fracture fixation; pertrochanteric fractures; arthroplasty and
Aims. This study aimed to compare the change in health-related quality
of life of patients receiving a traditional cemented monoblock Thompson
hemiarthroplasty compared with a modern cemented modular polished-taper
stemmed hemiarthroplasty for displaced
Introduction: Despite its common occurrence there is still controversy regarding the choice of treatment for the displaced
Continued controversy exists between cemented versus uncemented hemiarthroplasty for an