Introduction: Arthroscopic ankle arthrodesis has been shown in other studies to be a viable alternative to open arthrodesis for end stage arthritis. Its demonstrated advantages include comparable or better rates of fusion, reduced morbidity, shorter hospital stays, quicker times to union and reduced wound complications, especially in patients prone to wound healing problems. However, two main restrictions have been shown in the literature; its limited ability for deformity correction and the subsequent need for metalwork removal, commonly for pain or prominence. Aims: This study sought to investigate the need for metalwork removal, with the specific question of whether the use of a
Aims. This study aimed to establish the optimal fixation methods for calcaneal tuberosity avulsion fractures with different fragment thicknesses in a porcine model. Methods. A total of 36 porcine calcanea were sawed to create simple avulsion fractures with three different fragment thicknesses (5, 10, and 15 mm). They were randomly fixed with either two suture anchors or one
Scaphoid fractures accounts for approximately 15% of all fractures of hand and wrist. Proximal pole fractures represent 10–20% of scaphoid fractures. Non –operative treatment shows high incidence of non-union and avascular necrosis. Surgical intervention with bone graft is associated with better outcome. The aim of this study was to evaluate the radiological and functional outcome of management of proximal pole scaphoid non-union with internal fixation and bone grafting. We included 35 patients with proximal pole scaphoid non-union (2008–2015). All patients underwent antegrade
Abstract. Introduction. Fractures of the articular surface of the patella or the lateral femoral condyle usually occur following acute dislocation of the patella. This study looked at the radiological and functional outcomes of fixation of osteochondral fractures. Methods. Twenty-nine patients (18 male, 11 female) sustained osteochondral fractures of the knee following patellar dislocation. All patients had detailed radiographic imaging and MRI scan of the knee preoperatively. An arthroscopic assessment was done, followed by fixation using bio-absorbable pins or
Introduction. Calcaneal osteotomy is often performed together with other procedures to correct hindfoot deformity. There are various methods of fixation ranging from staples, headed or
Longstanding un-united scaphoid fractures or scapholunate insufficiency can progress to degenerative wrist osteoarthritis (termed scaphoid non-union advanced collapse (SNAC) or scapho-lunate advanced collapse (SLAC) respectively). Scaphoid excision and partial wrist fusion is a well-established procedure for the surgical treatment of this condition. In this study we present a novel technique and mid-term results, where fusion is reserved for the luno-capitate and triquetro-hamate joints, commonly referred to as bicolumnar fusion. The purpose of this study was to report functional and radiological outcomes in a series of patients who underwent this surgical technique. This was a prospective study of 23 consecutive patients (25 wrists) who underwent a bicolumnar carpal fusion from January 2014 to January 2017 due to a stage 2 or 3 SNAC/SLAC wrist, with a minimum follow-up of one year. In all cases two retrograde cannulated
The August 2012 Wrist &
Hand Roundup. 360. looks at: the Herbert ulnar head prosthesis; the five-year outcome for wrist arthroscopic surgery; four-corner arthrodesis with
Radial head fractures with fragment displacement should be reduced and fixed, when classified as Mason II type injuries. We describe a method of arthroscopic fixation which is performed as a day case trauma surgery, and compare the results with a more traditional fixation approach, in a case controlled manner. We prospectively reviewed six Mason II radial head fractures which were treated using an arthroscopic reduction and fixation technique. The technique allows the fracture to be mobilised, reduced, and anatomically fixed using
Background. Whereas arthroscopic arthrodesis of the ankle is commonplace and of the subtalar joint is established, reports of arthroscopic talo-navicular fusion are a rarity. Aim. To review a case series to establish if arthroscopic talo-navicular arthrodesis is a feasible surgical option. Methods. Arthroscopic decortication of the talo-navicular joint is performed via x1-2 sinus tarsi portals and x1-2 accessory talo-navicular portals using a standard arthroscope and a 4.5 barrel burr. Internal fixation is by a 5mm screw from the navicular tuberosity and x2
Distal interphalangeal joint (DIPJ) fusion using a k-wire has been the gold standard treatment for DIPJ arthritis. Recent studies have shown similar patient outcomes with the
Introduction: Many mini compression screws are now available for fixation in procedures such as metatarsal osteotomies or arthrodeses of the foot. The aim of the current study is to compare the compression forces achieved by mini compression screws on cortical and cancellous bone models. Material and Methods: The screws that were tested are listed in the table below. The compression forces were tested by inserting a pressures load measurement cell between longitudinally-split sheep tibia as a cortical bone model and longitudinally split retrieved femoral heads as a cancellous bone model. Results: The Headed AO 3.5 mm cortical screw gave the best compression force and the Bold was the weakest, both in cortical and cancellous bone. The relative compression forces of the other tested screws were different between cortical and cancellous bone. Compression with the
Introduction: Many mini compression screws are now available for fixation in procedures such as metatarsal osteotomies or arthrodeses of the foot. The aim of the current study is to compare the compression forces achieved by the relatively new commercial mini compression screws on cortical and cancellous bone models. Material and Methods: The screws that were tested are listed in the table below. All screws apart from the AO
Introduction. Hoffa fractures are rare, intra-articular fractures of the femoral condyle in the coronal plane and involving the weight-bearing surface of the distal femur. Surgical fixation is warranted to achieve stability, early mobilisation and satisfactory knee function. We describe a unique type of Hoffa fracture in the coronal plane with sagittal split and intra-articular comminution. There is scant evidence in current literature with regards to surgical approaches, techniques and implants. We report of our case with a review of the literature. Case report. A 40 year old male motorcyclist was involved in a high speed road traffic collision. X-rays confirmed displaced unicondylar fracture of the lateral femoral condyle. CT showed sagittal split of the Hoffa fragment and intra-articular comminution. MRI showed partial rupture of the anterior cruciate ligament. The patient underwent definitive surgical treatment via a midline skin incision and lateral parapatellar approach using cannulated
Introduction. Scaphoid fractures are commonly treated with a single
Trans-articular coronal shear fractures of the distal humerus pose a significant challenge to the surgeon in obtaining an anatomical reduction and rigid fixation and thereby return of good function. A variety of approaches have been described which include the extended lateral and anterolateral approaches and arthroscopically-assisted fixation for non-comminuted fractures. Fixation methods include open or percutaneous cannulated
Aim. Distal interphalangeal joint (DIPJ) arthrodesis is a well-accepted treatment of disease in the DIPJ of the hand. The ideal technique should be technically simple, quick, cheap, have minimal complications and yield a rapid return to function. Recent large published series report major complications of 11.1% and minor complications of 26% for this procedure. The study objective is to determine patient satisfaction and complication rates of DIPJ fusion using the Autofix screw (Small Bone Innovations, France), a smaller diameter
Introduction. Isolated trochlea fractures are very rare and have only been described previously as case reports. Aims. To report on a case of isolated trochlea fracture and to present a review of the literature. Results. There have only been four previous reports of isolated trochlea fracture. Our fifth case is included in the analysis of the literature given below. Average age 26 (Range 12–33). 60% female, 80% left sided. Dominance only stated in 40% of cases- 50% dominant side. Mechanism of injury: 60% low velocity fall onto an outstretched hand, 40% high velocity- RTA & fall off horse- exact mechanism of injury unknown. Patients all presented with elbow held in flexion, pain and swelling over the medial aspect and a painfully reduced range of motion. Diagnosis made on plain radiographs in 80%, tomograms required in 20%. AP noted to be essential to differentiate from more common capitellum fracture. 20% of fractures associated with comminution. Management consisted of open reduction through a medial approach and internal fixation in 80% (20%
Shape memory staples have several uses in both hand and foot and ankle surgery. There is relatively little data available regarding the biomechanical properties of staples, in terms of both the compression achieved and potential decay of mechanical advantage with time. An understanding of these properties is therefore important for the surgeon. Two blocks of synthetic polyurethane mimicking properties of cancellous bone were fixed in jigs to both the actuator and 6 degree-of-freedom load cell of an MTS servohydraulic testing machine. With the displacement between the blocks held constant the peak value and subsequent decay in compressive force applied by both the smooth and barbed version of the nitinol OSStaple (Biomedical Enterprises), Easyclip (LMT), Herbert Bone Screws (Martin) and the
Osteochondral fracture of the femoral head is an uncommon injury with a high potential for a poor functional outcome. Management is often challenging with limited options. We present two cases in which osteochondral fractures of the femoral head were treated with partial resurfacing using the HemiCAP System (Arthrosuface, Franklin MA, USA). Patient 1. A 22-year-old male professional motorbike rider presented with an anterior left hip dislocation that occurred during a race. A CT scan after a closed reduction revealed a large osteochondral impaction fracture/defect that was addressed via partial resurfacing using the HemiCAP System. Patient 2. A 34-year-old male presented with an anterior left hip dislocation after a motor vehicle accident and underwent a closed reduction. CT showed a loose osteochondral fragment, that was fixed back with
Introduction and Aims:. The surgical treatment of fractures of the scaphoid with delayed presentation or with established non-union pose a formidable challenge with reported failure rates between 15% and 45%. The aim of this study is to report the results of percutaneous versus open fixation with bone grafting of these fractures. Method:. 34 Consecutive patients who underwent surgery between 2009 and 2013 for delayed presentation and established non-union of scaphoid fractures have been reviewed retrospectively. There were 27 males and 7 females with a mean age of 31 years (15 to 66). The mean delay from time of injury to operation was 12 weeks (4 weeks to 11 months) in the percutaneous fixation group and 19 months (5 months to 6 years) in the open fixation group. 19 Patients were treated with percutaneous screw fixation alone and 15 patients underwent open reduction and internal fixation supplemented with autogenous corticocancellous iliac bone graft. The classification of Slade and Dodds (2009) was used as a guide for surgical treatment and the Mini-Acutrak