Aims. The Exeter V40 cemented
Early micromotion of hip implants measured with radiostereometric analysis (RSA) is a predictor for late aseptic loosening. Computed Tomography Radiostereometric Analysis (CT-RSA) can be used to determine implant micro-movements using low-dose CT scans. CT-RSA enables a non-invasive measurement of implants. We evaluated the precision of CT-RSA in measuring early stem migration. Standard marker-based RSA was used as reference. We hypothesised that CT-RSA can be used as an alternative to RSA in assessing implant micromotions. We included 31 patients undergoing Total Hip Arthroplasty (THA). Distal
The Accolade®TMZF is a taper-wedge cementless metaphyseal coated
INTRODUCTION. Short
Aims. The Exeter V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems. Methods. A systematic literature search was performed adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. In parallel, we performed a retrospective single centre study of Exeter V40
Purpose. Short metaphyseal fitting
Aims. The aim of this study was to compare the design of the generic
OptiStem XTR
Background. Short bone-conserving
Fixation of cemented
As an increasing number of young, active, large patients are becoming candidates for total hip replacements, there is an increasingly urgent need to identify arthroplasties that will be durable, highly functional and amenable to possible future successful revision. In an era when cemented
Purpose. The purpose of this study was to evaluate and compare the clinical, radiological outcomes of the group of patients with distal femoral cortical hypertrophy (DFCH) and without DFCH after hip arthroplasty using a cementless double tapered
Aims. Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the
Background. Safety and efficacy of novel prostheses relies on the determination of early implant migration and subsequent risk of loosening. Radiostereometric Analysis (RSA) has been used to evaluate the clinical failure risks of
Background. It is known that excessive varus alignment of the
Aims: The bone – conductive proparties of hydroxyapatite (HA) coatings are attractive in revision surgery with bone loss. The purpose of this study is to analyse the clinical and radiological results of 55 cases of revision hip arthroplasty using hydroxyapatite
Aims. This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component. Methods. We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018. Results. Of the surviving 30 patients (34 THAs), there were four periprosthetic fractures: one underwent femoral revision after 21 years, two had surgical fixation as the stem was deemed stable, and one was treated nonoperatively due to the patient’s comorbidities. The periprosthetic fracture patients showed radiological evidence of change in bone stock around the
The Lubinus SP II is an anatomical
It is known that excessive varus alignment of the
We report the results of the Charnley Elite Plus
INTRODUCTION:. Modular