Full-thickness
Aims. Physician burnout and its consequences have been recognized as increasingly prevalent and important issues for both organizations and individuals involved in healthcare delivery. The purpose of this study was to describe and compare the patterns of self-reported wellness in orthopaedic surgeons and trainees from multiple nations with varying health systems. Methods. A cross-sectional survey of 774 orthopaedic surgeons and trainees in five countries (Australia, Canada, New Zealand, UK, and USA) was conducted in 2019. Respondents were asked to complete the Mayo Clinic Well-Being Index and the Stanford Professional Fulfillment Index in addition to 31 personal/demographic questions and 27 employment-related questions via an anonymous online survey. Results. A total of 684 participants from five countries (Australia (n = 74), Canada (n = 90), New Zealand (n = 69), UK (n = 105), and USA (n = 346)) completed both of the risk assessment questionnaires (Mayo and Stanford). Of these, 42.8% (n = 293) were trainees and 57.2% (n = 391) were attending surgeons. On the Mayo Clinic Well-Being Index, 58.6% of the overall sample reported feeling
Tourniquet is a commonly used tool in orthopaedic practice. Incidence of complications is low but if any develops, it is devastating. Transient nerve damage, ischemia or skin
Major orthopaedic fractures are an independent risk factor for the development of venous thromboembolism (VTE), which are significant causes of preventable morbidity and mortality in trauma patients. Despite thromboprophylaxis, patients who sustain a pelvic or acetabular fracture (PA) continue to have high rates of VTE (12% incidence). Thrombelastography (TEG) is a whole-blood, point-of-care test which provides an overview of the clotting process. Maximal amplitude (MA), from TEG analysis, is the measure of clot strength and values ≥65mm have been used to quantify hypercoagulability and increased VTE risk. Therefore, the primary aim was to use serial TEG analysis to quantify the duration of hypercoagulability, following surgically treated PA fractures. This is a single centre, prospective cohort study of adult patients 18 years or older with surgically treated PA fractures. Consecutive patients were enrolled from a Level I trauma centre and blood draws were taken over a 3-month follow-up period for serial TEG analysis. Hypercoagulability was defined as MA ≥65mm. Exclusion criteria: bleeding disorders, active malignancy, current therapeutic anticoagulation,
The number of total knee arthroplasties continues to increase annually with over 90,000 total knee replacements performed in the United Kingdom in 2018. Multiple national bodies including the British Association for Surgery of the Knee (BASK) and the British Orthopaedic Association collaborated in July 2019 to produce best practice guidance for knee arthroplasty surgery. This study aims to review practice in a regional healthcare trust against these guidelines. Fifty total knee replacement operation notes were reviewed between January and February 2020 from 11 different consultant orthopaedic surgeons. Documents were assessed against 17 criteria recommended by the BASK guidance. Personnel names and grades were generally well documented. Tourniquet time and pressure were documented in over 98% of operation notes however, protection from spirit
Instances of skin
Heterotopic ossification (HO) is the formation of bone at extra-skeletal sites. Genetic diseases, traumatic injuries, or severe
Objectives. Injectable Bromelain Solution (IBS) is a modified investigational derivate of the medical grade bromelain-debriding pharmaceutical agent (NexoBrid) studied and approved for a rapid (four-hour single application), eschar-specific, deep
Radio Frequency Ablation (RFA) is a precise CT-guided technique to generate a small pre-defined field of dissecated tissue. Its’ present use in orthopaedic oncology is to treat osteoid osteoma. We have also treated other lesions with RFA and want to report our present indications and complications. From 2005 to 2008 we performed 30 procedures: 23 osteoid osteomas, five low-grade chondrosarcomas, one chondroblastoma and one thyroid metastasis. Localisations were femur in 14 cases, tibia in 10, calcaneus in two, fibula in two, sacrum in one and scapula in one. All patients were treated with CT- guided RFA (Boston Scientific). Follow-up for osteoid osteoma was done without additional imaging, all patients but one were pain free within 2 weeks; this one patient proved to have a chronic osteomyelitis although we thought we saw a nidus on CT. In one patient a
Introduction: Knee arthroscopy is one of the most commonly performed orthopaedic procedures. All orthopaedic surgeons have heard anecdotal stories of thermal injury and drape combustion, yet a literature search has failed to find any papers reviewing the nature of such risks. Materials and methods: A thermocouple attached to a laptop computer was used to record the temperature at the arthroscope tip, the light cable end and the light source generator. All potentially flammable materials commonly used during arthroscopic surgery (various disposable drapes, cotton drapes, gowns, paper towels and swabs), were placed at measured distances from a) the light cable end and b) the arthroscope tip. Results: The arthroscope tip reached a maximum temperature of 41.90° in 200 seconds. The light cable tip reached 80° at 100 seconds and a maximum temperature of 110°C in 342 seconds. The light source generator reached a temperature of 153°C. All materials tested (except cotton swabs) underwent signs of combustion. The disposable drapes burnt most rapidly. None of the materials considered had any evidence of thermal damage when placed at distances of 2.5 cm beyond the light cable and 0.5 cm beyond the arthroscope tip. Combustion was most rapid at a distance of 5mm from the instruments. Most surgeons consider the arthroscope tip or light cable end to be the site most likely to induce combustion. Fuel, heat and oxygen are required to produce combustion. Direct contact with the tip results in greater exposure to heat but lower oxygen availability. The fasted combustion occurred at 5mm due to higher oxygen availability despite a lower temperature. Conclusions and Recommendations:. Disposable drapes will
Introduction. This study reviews the orthopaedic care of the thirteen patients who were admitted and treated at Royal Manchester Children's' Hospital following the Manchester Arena Bomb blast. Methods. We included all children admitted to Royal Manchester Children's Hospital injured following the bomb blast who either suffered upper limb, lower limb or pelvic fractures, or penetrating upper or lower limb wounds. The nature of each patient's bone and soft tissue injuries, initial and definitive management, and outcome were assessed and documented. Main outcome measures were time to fracture union, time to definitive soft tissue/skin healing, and functional outcome. Findings. Thirteen children were admitted with orthopaedic injuries; 12 were female and mean age was 12.69. All patients had penetrating deep wounds with at least one large nut foreign body in situ, two patients suffered significant
Paediatric fractures are highly prevalent and are most often treated with plaster. The application and removal of plaster is often an anxiety-inducing experience for children. Decreasing the anxiety level may improve the patients’ satisfaction and the quality of healthcare. Virtual reality (VR) has proven to effectively distract children and reduce their anxiety in other clinical settings, and it seems to have a similar effect during plaster treatment. This study aims to further investigate the effect of VR on the anxiety level of children with fractures who undergo plaster removal or replacement in the plaster room. A randomized controlled trial was conducted. A total of 255 patients were included, aged five to 17 years, who needed plaster treatment for a fracture of the upper or lower limb. Randomization was stratified for age (five to 11 and 12 to 17 years). The intervention group was distracted with VR goggles and headphones during the plaster treatment, whereas the control group received standard care. As the primary outcome, the post-procedural level of anxiety was measured with the Child Fear Scale (CFS). Secondary outcomes included the children’s anxiety reduction (difference between CFS after and CFS before plaster procedure), numerical rating scale (NRS) pain, NRS satisfaction of the children and accompanying parents/guardians, and the children’s heart rates during the procedure. An independent-samples Aims
Methods
Aims. Ilizarov described four methods of treating non-unions but gave little information on the specific indications for each technique. He claimed, ‘infection
Scar tissue formation between nerve and surrounding muscle is one of the most undesired occurrence in nerve surgery In order to prevent scar tissue apposition after surgery, a lot of biocompatible products have been developed and tested first of all on animal models and then in surgical practice. we tested the efficacy of a CMC-PEO gel in reduction of perineural scar tissue formation in a mice model and in a small group of patients. We performed surgical procedures on 26 male mices The animals were randomized into three groups. In each group the muscular bed of sciatic nerve was
With up to 40% of patients having patellofemoral joint osteoarthritis (PFJ OA), the two arthroplasty options are to replace solely the patellofemoral joint via patellofemoral arthroplasty (PFA), or the entire knee via total knee arthroplasty (TKA). The aim of this study was to assess postoperative success of second-generation PFAs compared to TKAs for patients treated for PFJ OA using patient-reported outcome measures (PROMs) and domains deemed important by patients following a patient and public involvement meeting. MEDLINE, EMBASE via OVID, CINAHL, and EBSCO were searched from inception to January 2022. Any study addressing surgical treatment of primary patellofemoral joint OA using second generation PFA and TKA in patients aged above 18 years with follow-up data of 30 days were included. Studies relating to OA secondary to trauma were excluded. ROB-2 and ROBINS-I bias tools were used.Aims
Methods
The aim of this study was to develop a core outcome set of what to measure in all future clinical research on hand fractures and joint injuries in adults. Phase 1 consisted of steps to identify potential outcome domains through systematic review of published studies, and exploration of the patient perspective through qualitative research, consisting of 25 semi-structured interviews and five focus groups. Phase 2 involved key stakeholder groups (patients, hand surgeons, and hand therapists) prioritizing the outcome domains via a three-round international Delphi survey, with a final consensus meeting to agree the final core outcome set.Aims
Methods
Safety concerns surrounding osseointegration are a significant barrier to replacing socket prosthesis as the standard of care following limb amputation. While implanted osseointegrated prostheses traditionally occur in two stages, a one-stage approach has emerged. Currently, there is no existing comparison of the outcomes of these different approaches. To address safety concerns, this study sought to determine whether a one-stage osseointegration procedure is associated with fewer adverse events than the two-staged approach. A comprehensive electronic search and quantitative data analysis from eligible studies were performed. Inclusion criteria were adults with a limb amputation managed with a one- or two-stage osseointegration procedure with follow-up reporting of complications.Aims
Methods
Dead-space management, following dead bone resection, is an important element of successful chronic osteomyelitis treatment. This study compared two different biodegradable antibiotic carriers used for dead-space management, and reviewed clinical and radiological outcomes. All cases underwent single-stage surgery and had a minimum one-year follow-up. A total of 179 patients received preformed calcium sulphate pellets containing 4% tobramycin (Group OT), and 180 patients had an injectable calcium sulphate/nanocrystalline hydroxyapatite ceramic containing gentamicin (Group CG). Outcome measures were infection recurrence, wound leakage, and subsequent fracture involving the treated segment. Bone-void filling was assessed radiologically at a minimum of six months post-surgery.Aims
Methods
The aim of this study was to explore clinicians’ experience of a paediatric randomized controlled trial (RCT) comparing surgical reduction with non-surgical casting for displaced distal radius fractures. Overall, 22 staff from 15 hospitals who participated in the RCT took part in an interview. Interviews were informed by phenomenology and analyzed using thematic analysis.Aims
Methods
Introduction. The role of diathermy in orthopaedic surgical practice has increased since its introduction. It is widely used for underlying tissue dissection, cutting, and haemostasis. Previous studies have compared electrosurgical and scalpel incisions in terms of wound infection, wound-related pain, and blood loss. There are well documented hazards associated with diathermy use including