Advertisement for orthosearch.org.uk
Results 1 - 20 of over 10000
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 34 - 34
1 Dec 2020
Pugliese E Zeugolis D
Full Access

The enthesis is a tissue interface between tendon and bone, essential for adequate force transmission and composed by four distinct zones, namely tendon, fibrocartilage, mineralized fibrocartilage and bone. Given the avascularity of the tendon and the gradual change in tissue architecture and cell phenotype, the enthesis original tissue is often not re-established after chronic injuries, resulting in scar formation. Conservative treatments and surgical approaches are still far from a functional regeneration, whilst tissue engineering based scaffolds have recently showed great potential. In this work, we hypothesised that collagen-based scaffolds that mimic the basic architecture of the enthesis, will be able to spatially direct stem cell differentiation, providing an in vitro platform to study enthesis regeneration. A three-layer sponge composed of a tendon-like layer (collagen type I), a fibrocartilage-like layer (collagen type II) and a bone-like layer (collagen type I and hydroxyapatite) was fabricated by an iterative layering freeze-drying technique. Scaffold pore size and structural continuity at the interfaces were assessed by SEM and μ-CT analysis. Bone-marrow derived stem cells (BMSCs) were seeded on the scaffold and cultured in basal and differentiation media (chondrogenic, tenogenic and osteogenic). At day 7 and 21 the scaffolds were stained with Alizarin Red and Alcian Blue; alkaline phosphatase activity (ALP) and calcium and glycosaminoglycans (GAGs) were quantified in order to evaluate BMSC differentiation towards osteogenic and chondrogenic lineage. The presence of collagen I, III, tenascin and decorin in the scaffolds was evaluated by immunofluorescence staining in order to evaluate tenogenic differentiation of BMSCs. Scaffolds with three distinct but interconnected layers of collagen type I, collagen type II and collagen type I + hydroxyapatite were fabricated, with pore sizes in the range of 100–200 μm. Increased ALP and calcium levels were detected in a localised manner within the bone-like layer when scaffolds were cultured in basal medium (p<0.025 vs the other 2 layers). Similarly, proteoglycans were detected specifically in the fibrocartilage-like layer when scaffolds were cultured in the chondrogenic differentiation medium (p<0.03 vs the other 2 layers). Increased expression of tenogenic markers was observed in the tendon-like layer of scaffolds cultured in tenogenic media (p<0.045 vs the other 2 layers). In conclusion, the different collagen composition of each layer was able to spatially direct BMSC differentiation in a localized manner within the scaffold. Ongoing work is evaluating the synergistic effect between growth factor functionalized within the fibrocartilage and tendon-like layers for improved BMSC differentiation. Overall, these scaffolds hold promising potential in developing novel and more efficient strategy towards enthesis regeneration


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 338 - 339
1 Jul 2008
Waheed A Eleftheriou K Khairandish H Hussein A James L Montgomery H Haddad F Simonis R
Full Access

The aetiology and pathophysiology of non-union is still unclear, but in this condition there is an abnormal bone metabolism. The paracrine matrix RAS has been implicated in the regulation of bone remodeling and injury responses, possibly via its effects on kinins. The influence of the local RAS or the genetic influence of the ACE/ BK2R genes to bone remodelling may thus be central to the disorder, or augmented in these conditions. We thus compared the distribution of the ACE I/D and BK2R “+9/-9” functional polymorphisms in patients with non-union and compared them to appropriate control. Gene analysis was performed on buccal cells collected from all subjects and the data was analysed for 59 patients (46 males, 13 females; mean age 40.1±15.7 years) with non-union and 81 control subjects (49 males, 32 females; mean age 51.4±22.81 years. The overall genotype distribution was consistent with Hardy-Wein-berg equilibrium for the overall and individual groups for ACE (p0.16), B1BKR (p0.68) and B2BKR genotypes (p0.12). As the -9 allele is associated with greater gene transcription and higher mRNA expression of the receptor we combined the -9/-9 homozygous and -9/+9 heterozygous groups and compared them with the homozygous +9/+9 groups. This showed a significant difference between the non-union and control groups, with the +9/+9 homozygous being less prominent in the former (p=0.03). The B2BKR -9 allele is associated with the incidence of non-union in fracture healing, in this first study to address this question. We found no association with either the ACE I/D or B1BKR genotypes. In conclusion, with previous findings that the absence of the -9 allele of the B2BKR +9/-9 polymorphism is associated with greater gene transcription and higher mRNA expression of the receptor our findings are suggestive that increased BK activity via the B2BKR may predispose to the development of non-union


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 89 - 89
11 Apr 2023
Dascombe L Le Maitre C Aberdein N
Full Access

This study aimed to characterise the microarchitecture of bone in different species of animal leading to the development of a physiologically relevant 3D printed cellular model of trabecular (Tb) and cortical bone (CB). Using high resolution micro-computed tomography (μ-CT) bone samples from multiple species were scanned and analysed before creating in silico models for 3D printing. Biologically relevant printing materials with physical characteristics similar to that of in vivo bone will be selected and tested for printability. Porcine and murine bone samples were scanned using μ-CT, with a resolution of 4.60 μM for murine and 11 μM for porcine and reconstructed to determine the architectural properties of both Tb and CB independently. A region of interest, 1 mm in height, will be used to generate an in-silico 3D model with dimensions (10 mm. 3. ) and suitable resolution before being translated into printable G code using CAD assisted software. A 1 mm section of each bone was analysed, to determine the differences in the microarchitecture with the intent of setting a benchmark for the developmental 3D in vitro model to be comparable against. In contrast, porcine caudal vertebrae (PCV) have an increased volume due to the size of the bone sample. Interestingly, BV/TR for Tb is similar between species in all samples except murine femur. Murine tibia and PCV have a similar Tb. number and thickness, however different SMI shape and separation. μ-CT scanning and analysis permits tessellation of the 3D output which will lead to the generation of an in silico printable model. Biomaterials are currently under optimisation to allow printability and shape integrity to reflect the morphological and physiological properties of bone


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 17 - 17
1 Dec 2022
Ciapetti G Granchi D Perut F Spinnato P Spazzoli B Cevolani L Donati DM Baldini N
Full Access

Fracture nonunion is a severe clinical problem for the patient, as well as for the clinician. About 5-20% of fractures does not heal properly after more than six months, with a 19% nonunion rate for tibia, 12% for femur and 13% for humerus, leading to patient morbidity, prolonged hospitalization, and high costs. The standard treatment with iliac crest-derived autologous bone filling the nonunion site may cause pain or hematoma to the patient, as well as major complications such as infection. The application of mesenchymal autologous cells (MSC) to improve bone formation calls for randomized, open, two-arm clinical studies to verify safety and efficacy. The ORTHOUNION * project (ORTHOpedic randomized clinical trial with expanded bone marrow MSC and bioceramics versus autograft in long bone nonUNIONs) is a multicentric, open, randomized, comparative phase II clinical trial, approved in the framework of the H2020 funding programme, under the coordination of Enrique Gòmez Barrena of the Hospital La Paz (Madrid, Spain). Starting from January 2017, patients with nonunion of femur, tibia or humerus have been actively enrolled in Spain, France, Germany, and Italy. The study protocol encompasses two experimental arms, i.e., autologous bone marrow-derived mesenchymal cells after expansion (‘high dose’ or ‘low dose’ MSC) combined to ceramic granules (MBCP™, Biomatlante), and iliac crest-derived autologous trabecular bone (ICAG) as active comparator arm, with a 2-year follow-up after surgery. Despite the COVID 19 pandemic with several lockdown periods in the four countries, the trial was continued, leading to 42 patients treated out of 51 included, with 11 receiving the bone graft (G1 arm), 15 the ‘high dose’ MSC (200x10. 6. , G2a arm) and 16 the ‘low dose’ MSC (100x10. 6. , G2b arm). The Rizzoli Orthopaedic Institute has functioned as coordinator of the Italian clinical centres (Bologna, Milano, Brescia) and the Biomedical Science and Technologies and Nanobiotechnology Lab of the RIT Dept. has enrolled six patients with the collaboration of the Rizzoli’ 3rd Orthopaedic and Traumatological Clinic prevalently Oncologic. Moreover, the IOR Lab has collected and analysed the blood samples from all the patients treated to monitor the changes of the bone turnover markers following the surgical treatment with G1, G2a or G2b protocols. The clinical and biochemical results of the study, still under evaluation, are presented. * ORTHOUNION Horizon 2020 GA 733288


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 45 - 45
11 Apr 2023
Hanetseder D Hruschka V Redl H Marolt Presen D
Full Access

Regeneration of bone defects in elderly patients is limited due to the decreased function of bone forming cells and compromised tissue physiology. Previous studies suggested that the regenerative activity of stem cells from aged tissues can be enhanced by exposure to young systemic and tissue microenvironments. The aim of our project was to investigate whether extracellular matrix (ECM) engineered from human induced pluripotent stem cells (hiPSCs) can enhance the bone regeneration potential of aged human bone marrow stromal cells (hBMSCs). ECM was engineered from hiPSC-derived mesenchymal-like progenitors (hiPSC-MPs), as well as young (<30 years) and aged (>70 years) hBMSCs. ECM structure and composition were characterized before and after decellularization using immunofluorescence and biochemical assays. Three hBMSCs of different ages were cultured on engineered ECMs. Growth and differentiation responses were compared to tissue culture plastic, as well as to collagen and fibronectin coated plates. Decellularized ECMs contained collagens type I and IV, fibronectin, laminin and < 5% residual DNA, suggesting efficient cell elimination. Cultivation of young and aged hBMSCs on the hiPSC-ECM in osteogenic medium significantly increased hBMSC growth and markers of osteogenesis, including collagen deposition, alkaline phosphatase activity, bone sialoprotein expression and matrix mineralization compared to plastic controls and single protein substrates. In aged BMSCs, matrix mineralization was only detected in ECM cultures in osteogenic medium. Comparison of ECMs engineered from hiPSC-MPs and hBMSCs of different ages suggested similar structure, composition and potential to enhance osteogenic responses in aged BMSCs. Engineered ECM induced a higher osteogenic response compared to specific matrix components. Our studies suggest that aged BMSCs osteogenic activity can be enhanced by culture on engineered ECM. hiPSCs represent a scalable cell source, and tissue engineering strategies employing engineered ECM materials could potentially enhance bone regeneration in elderly patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 49 - 49
11 Apr 2023
Speirs A Melkus G Rakhra K Beaule P
Full Access

Femoroacetabular impingement (FAI) results from a morphological deformity of the hip and is associated with osteoarthritis (OA). Increased bone mineral density (BMD) is observed in the antero-superior acetabulum rim where impingement occurs. It is hypothesized that the repeated abnormal contact leads to damage of the cartilage layer, but could also cause a bone remodelling response according to Wolff's Law. Thus the goal of this study was to assess the relationship between bone metabolic activity measured by PET and BMD measured in CT scans. Five participants with asymptomatic cam deformity, three patients with uni-lateral symptomatic cam FAI and three healthy controls were scanned in a 3T PET-MRI scanner following injection with [18F]NaF. Bone remodelling activity was quantified with Standard Uptake Values (SUVs). SUVmax was analyzed in the antero-superior acetabular rim, femoral head and head-neck junction. In these same regions, BMD was calculated from CT scans using the calibration phantom included in the scan. The relationship between SUVmax and BMD from corresponding regions was assessed using the coefficient of determination (R. 2. ) from linear regression. High bone activity was seen in the cam deformity and acetabular rim. SUVmax was negatively correlated with BMD in the antero-superior region of the acetabulum (R. 2. =0.30, p=0.08). SUVmax was positively correlated with BMD in the antero-superior head-neck junction of the femur (R. 2. =0.359, p=0.067). Correlations were weak in other regions. Elevated bone turnover was seen in patients with a cam deformity but the relationship to BMD was moderate. This study demonstrates a pathomechanism of hip degeneration associated with FAI deformities, consistent with Wolff's law and the proposed mechanical cause of hip degeneration in FAI. [18F]-NaF PET SUV may be a biomarker of degeneration, especially in early stages of degeneration, when joint preservation surgery is likely to be the most successful


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 41 - 41
11 Apr 2023
Deegan A Lawlor L Yang X Yang Y
Full Access

Our previous research has demonstrated that minor adjustments to in vitro cellular aggregation parameters, i.e. alterations to aggregate size, can influence temporal and spatial mineral depositions within maturing bone cell nodules. What remains unclear, however, is how aggregate size might affect mineralisation within said nodules over long-term in vivo culture. In this study, we used an osteoblast cell line, MLO-A5, and a primary cell culture, mesenchymal stem cells (MSC), to compare small (approximately 80 µm) with large (approximately 220 µm) cellular aggregates for potential bone nodule development after 8 weeks of culturing in a mouse model (n = 4 each group). In total, 30 chambers were implanted into the intra-peritoneal cavity of 20 male, immunocompromised mice (MF1-Nu/Nu, 4 – 5 weeks old). Nine small or three large aggregates were used per chamber. Neoveil mesh was seeded directly with 2 × 10. 3. cells for monolayer control. At 8 weeks, the animals were euthanised and chambers fixed with formalin. Aggregate integrity and extracellular material growth were assessed via light microscopy and the potential mineralisation was assessed via micro-CT. Many large aggregates appeared to disintegrate, whilst the small aggregates maintained their form and produced additional extracellular material with increased sizes. Both MLO-A5 cells and MSC cells saw similar results. Interestingly, however, the MSCs were also seen to produce a significantly higher volume of dense material compared to the MLO-A5 cells from micro-CT analysis. Overall, a critical cell aggregate size appeared to exist balancing optimal tissue growth with oxygen diffusion, and cell source may influence differentiation pathway despite similar experimental parameters. The MSCs, for example, were likely producing bone via the endochondral ossification pathway, whilst the matured bone cells, MLO-A5 cells, were likely producing bone via the intramembranous ossification pathway


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 8 - 8
2 Jan 2024
Koshanova A Tuleubayev B Saginova D Akhmetova S Tashmetov E
Full Access

Bone infections due to fractures or implants are a big medical problem. In experimental medicine, many experimental models have been created on different animal species to simulate the disease condition and to do experience treatments. The aim of this paper was to present an antibacterial efficacy of using a bone allograft developed according to the Marburg system of bone bank on a model of chronic osteomyelitis induced in rabbits. In research was used 54 rabbits. Osteomyelitis was induced in rabbits by a human strain of St. aureus ATCC 43300, in the rabbit femur. There have been created 3 groups of animals. In 1. st. group used antibiotic impregnated biodegradable material “PerOssal”. In 2. nd. group used antibiotic impregnated whole bone allograft. In 3. rd. group used antibiotic impregnated perforated bone allograft. Evaluation of installation and evolution of the disease was done by microbiological. A separate study of microbiological data is presented here. This study showed, in the 1. st. and 3. rd. groups there is a persistent decrease in CFU by 14 knocks to 120.4 in the 1. st. group and to 3.5 in the 3. rd. group, and in the 2. nd. group, on the contrary, there is an increase in CFU to 237.33. This shows the lack of effectiveness of using a whole bone allograft. The results showed, after 7 days there was no statistically significant difference between the groups. After 14 days the perforated bone allograft impregnated with antibiotic was better than the biodegradable material “PerOssal”


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 134 - 134
2 Jan 2024
Häusner S Horas K Blunk T Herrmann M
Full Access

Autografts containing bone marrow (BM) are current gold standard in the treatment of critical size bone defects, delayed union and bone nonunion defects. Although reaching unprecedented healing rates in bone reconstruction, the mode of action and cell-cell interactions of bone marrow mononuclear cell (BM-MNC) populations have not yet been described. BM-MNCs consist of a heterogeneous mixture of hematopoetic and non-hematopoetic lineage fractions. Cell culture in a 3D environment is necessary to reflect on the complex mix of these adherend and non-adherend cells in a physiologically relevant context. Therefore, the main aim of this approach was to establish conditions for a stable 3D BM-MNC culture to assess cellular responses on fracture healing strategies. BM samples were obtained from residual material after surgery with positive ethical vote and informed consent of the patients. BM-MNCs were isolated by density gradient centrifugation, and cellular composition was determined by flow cytometry to obtain unbiased data sets on contained cell populations. Collagen from rat tail and human fibrin was used to facilitate a 3D culture environment for the BM-MNCs over a period of three days. Effects on cellular composition that could improve the regenerative potential of BM-MNCs within the BM autograft were assessed using flow cytometry. Cell-cell-interactions were visualized using confocal microscopy over a period of 24 hours. Cell localization and interaction partners were characterized using immunofluorescence labeled paraffin sectioning. Main BM-MNC populations like Monocytes, Macrophages, T cells and endothelial progenitor cells were determined and could be conserved in 3D culture over a period of three days. The 3D cultures will be further treated with already clinically available reagents that lead to effects even within a short-term exposure to stimulate angiogenic, osteogenic or immunomodulatory properties. These measures will help to ease the translation from “bench to bedside” into an intraoperative protocol in the end


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 13 - 13
17 Jun 2024
Aizah N Haseeb A Draman M
Full Access

Insertional Achilles tendinitis with considerable degeneration that failed non-operative treatment typically requires tendon debridement and reattachment to bone. It is common practice for tendons to be reattached back with anchor sutures, but this poses a challenge to patients who are not able to afford them. Bony anchorage of tendons may be performed by passing sutures through tunnels, but the strength of repair compared to by using anchors is not known. We investigated the load at clinical and catastrophic failure of these two methods of reattachment. Sixteen paired Achilles tendons along with the calcaneus were harvested from eight fresh frozen cadavers. Paired randomization was done. For the anchor suture group, two 5’0 anchors with polyethylene #2 sutures were used for reattachment whereas for the suture only group, tendons were reattached to bone using braided polyester #2 sutures via two bony tunnels. All samples were mounted on a materials testing system and preloaded at 50N for 60sec before load to failure at a rate of 1mm/sec. With the assumption that preloading has removed tendon crimp and any subsequent extension is a result of gapping at the repair site, loads at 5mm, 10mm, 15mm, and 20mm of extension were noted as well as the maximal load at failure. We found higher loads were needed to cause an extension of 5 to 20mm in the suture only group compared to the anchor suture group but these data were not significant. On the other hand, the anchor suture group required higher loads before catastrophic failure occurred compared to the suture only group, but this again is not significant. We conclude that suture only reattachment of the Achilles tendon is comparable in strength with anchor suture reattachment, and this method of reattachment can be considered for patients who do not have access to anchor sutures


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 25 - 25
1 Oct 2022
Casali M Rani N Cucurnia I Filanti M Coco V Reale D Zarantonello P Musiani C Zaffagnini M Romagnoli M
Full Access

Aim. Aim of this monocentric, prospective study was to evaluate the safety, efficacy, clinical and radiographical results at 24-month follow-up (N = 6 patients) undergoing hip revision surgery with severe acetabular bone defects (Paprosky 2C-3A-3B) using a combination of a novel phase-pure betatricalciumphosphate - collagen 3D matrix with allograft bone chips. Method. Prospective follow-up of 6 consecutive patients, who underwent revision surgery of the acetabular component in presence of massive bone defects between April 2018 and July 2019. Indications for revision included mechanical loosening in 4 cases and history of hip infection in 2 cases. Acetabular deficiencies were evaluated radiographically and CT and classified according to the Paprosky classification. Initial diagnosis of the patients included osteoarthritis (N = 4), a traumatic fracture and a congenital hip dislocation. 5 patients underwent first revision surgery, 1 patient underwent a second revision surgery. Results. All patients were followed-up radiographically with a mean of 25,8 months. No complications were observed direct postoperatively. HHS improved significantly from 23.9 preoperatively to 81.5 at the last follow-up. 5 patients achieved a defined good result, and one patient achieved a fair result. No periprosthetic joint infection, no dislocations, no deep vein thrombosis, no vessel damage, and no complaint about limbs length discrepancy could be observed. Postoperative dysmetria was found to be + 0.2cm (0cm/+1.0cm) compared to the preoperative dysmetria of − 2.4 cm (+0.3cm/−5.7cm). Conclusions. Although used in severe acetabular bone defects, the novel phase-pure betatricalciumphosphate - collagen 3D matrixshowed complete resorption and replacement by newly formed bone, leading to a full implant integration at 24 months follow-up and thus represents a promising method with excellent bone regeneration capacities for complex cases, where synthetic bone grafting material is used in addition to autografts


Bone & Joint Research
Vol. 10, Issue 12 | Pages 820 - 829
15 Dec 2021
Schmidutz F Schopf C Yan SG Ahrend M Ihle C Sprecher C

Aims. The distal radius is a major site of osteoporotic bone loss resulting in a high risk of fragility fracture. This study evaluated the capability of a cortical index (CI) at the distal radius to predict the local bone mineral density (BMD). Methods. A total of 54 human cadaver forearms (ten singles, 22 pairs) (19 to 90 years) were systematically assessed by clinical radiograph (XR), dual-energy X-ray absorptiometry (DXA), CT, as well as high-resolution peripheral quantitative CT (HR-pQCT). Cortical bone thickness (CBT) of the distal radius was measured on XR and CT scans, and two cortical indices mean average (CBTavg) and gauge (CBTg) were determined. These cortical indices were compared to the BMD of the distal radius determined by DXA (areal BMD (aBMD)) and HR-pQCT (volumetric BMD (vBMD)). Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC) were used to compare the results and degree of reliability. Results. The CBT could accurately be determined on XRs and highly correlated to those determined on CT scans (r = 0.87 to 0.93). The CBTavg index of the XRs significantly correlated with the BMD measured by DXA (r = 0.78) and HR-pQCT (r = 0.63), as did the CBTg index with the DXA (r = 0.55) and HR-pQCT (r = 0.64) (all p < 0.001). A high correlation of the BMD and CBT was observed between paired specimens (r = 0.79 to 0.96). The intra- and inter-rater reliability was excellent (ICC 0.79 to 0.92). Conclusion. The cortical index (CBTavg) at the distal radius shows a close correlation to the local BMD. It thus can serve as an initial screening tool to estimate the local bone quality if quantitative BMD measurements are unavailable, and enhance decision-making in acute settings on fracture management or further osteoporosis screening. Cite this article: Bone Joint Res 2021;10(12):820–829


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 100 - 100
1 Nov 2021
Papadia D Comincini F Pirchio P Puggioni V Bellanova G
Full Access

Introduction and Objective. Management of bone loss associated with bone contamination or infection represents a double biological and clinical challenge frequent in traumatology. The advent of new biomaterials can allow a different approach in the treatment of bone gap. The purpose of this study was to evaluate the prophylactic and therapeutic effectiveness of addition of a new absorbable bone substitute (BS) eluting different antibiotics in reconstruction of bone defects after infections and fractures with soft tissue damage. Materials and Methods. We conducted a review of patients with contaminated or infected bone defects treated using a new biomaterial, a porous composite of collagen matrices and Beta tricalcium phosphate (β TCP), able to provide a long-term release of different antibiotics. We have included treatment of osteomyelitis and osteosynthesis of exposed fracture (Gustilo Anderson 1–3b) or fractures with soft tissue damage and high risk of contamination. Surgical technique included debridement filling bone defect with BS eluting antibiotics, osteosynthesis (plate, nail, external fixator, kirschner wire), soft tissue coverage, and systemic antibiotic therapy. Radiographic and clinical data including complications (wound dehiscence, superficial or deep infection, osteomyelitis) were collected. Results. We treated 25 patients (21 male, 4 female) with mean age 47 yrs. (range 21–83). The locations treated (for incidence) was: 9 femurs (7 plates, 2 nail), 7 calcanei (one bilateral), 3 tibias, 2 forearms, 2 metatarsi, 2 hands, 1 elbow. 6 patients had large bone loss. 7 patients had bone infections (4 were Cierny Madern 4); 8 patients had osteosynthesis of exposed fractures Gustilo Anderson 1–3b (9 plate, one bilateral calcaneus). 8 patients had treatment for pseudoarthrosis of exposed fractures (6 femurs, 1 forearm, 1 metatarsus) and 3 patients a prophylactic treatment for calcaneal fractures with soft tissue damage. 4 deep infection were treated with multiple surgical debridement and new filling bone defect with BS eluting antibiotic with infection eradication. We have used a combination of vancomycin and gentamicin on 15 cases, vancomycin alone on 4 cases, combination of vancomycin and amikacin on 1 case and amikacin and Linezolid in a targeted multi drug resistance. At final follow-up functional outcome was good in all cases with bone healing. Conclusions. Extensive debridement is a fundamental requisite for eradication of bone infections and contamination. Filling of the bone void with loaded bio-composite eluting diversifiable local antibiotics with synergistic anti-biofilm activity is desirable. Treatment of this bone defects are advantaged when combining his reconstruction with BS and the possibility of release high antibiotic concentration at least for 10 days. This is an important complementing prophylactic and therapeutic antimicrobial option with adjuvant role to systemic therapy that enlarges the success rate


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 21 - 21
10 Jun 2024
Gordon C Raglan M Dhar S Lee K
Full Access

Objective. The purpose of this study was to determine the outcomes of revision ankle replacements, using the Invision implant and impaction allograft for massive talar dome defects following primary ankle replacement failure. Outcomes were assessed in terms of bone graft incorporation; improvement in patient reported outcome measures (PROMs); and survivorship of the revision ankle arthroplasty. Methods. A retrospective review of prospectively collected data identified eleven patients who had massive bone cysts and underwent revision of a failed primary total ankle replacement to the Invision revision system, combined with impaction grafting using morselized femoral head allograft. These revisions occurred at a single high volume ankle arthroplasty centre. Computed tomography (CT) scans were used to assess bone graft incorporation and the Manchester-Oxford Foot Questionnaire (MOXFQ) and EQ-5D scores were used pre and post operatively to assess PROMs. Results. The mean follow up was 18 months (12–48months). In all eleven patients, improvement was reported in the post-operative MOXFQ and EQ-5D scores. CT scans showed bone graft incorporation in all cases. None of the patients have required further surgery and are continue to do well clinically at latest follow up. Conclusions. In the short term, this study confirms revision ankle replacements with the Invision prosthesis and impaction with morselized femoral head allograft is a suitable revision option for primary ankle replacement failure with massive talar bone loss. Long term follow up continues of these complex patients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 115 - 115
1 May 2016
Dold P Pandorf T Flohr M Preuss R Bone M Holland J Deehan D
Full Access

INTRODUCTION. Deformation of modular acetabular press-fit shells is of much interest for surgeons and manufacturers. Initial fixation is achieved through press-fit between shell and acetabulum with the shell mechanically deforming upon insertion. Shell deformation may disrupt the assembly process of modular systems and may adversely affect integrity and durability of the components and tribology of the bearing. The aim of the study was to show shell deformation as a function of bone and shell stiffness. METHODS. The stiffness of the generic shells was determined using a uniaxial/ two point loading frame by applying different loads, and the change in dimension was measured by a coordinate measurement machine (CMM). Cadaver lab deformation measurements were done before and after insertion for 32 shells with 2 wall thicknesses and 11 shell sizes using the ATOS Triple Scan III (ATOS) optical system previously validated as a suitable measurement system to perform those measurements. Multiple deformation measurements per cadaver were performed by using both hip sides and stepwise increasing the reamed acetabulum by at least 1 mm, depending on sufficient residual bone stock. The under-reaming was varied between 0mm and 1mm, respectively. From the deformations, the resulting forces on the shells and bone stiffness were calculated assuming force equilibrium as well as linear-elastic material behaviour in each point at the rim of the shell. RESULTS. Radial stiffness for shells with 3 mm wall thickness ranged between 6257 N/mm and 2920 N/mm, with 4 mm wall thickness it ranged between 14341 N/mm and 6875 N/mm. The radial shell deformation ranged between 3 µm and 187 µm. The resulting maximum radial forces acting on the shells ranged between 26 N and 916 N. From these values, bone stiffness [N/mm] at the point of the maximum deformation has been calculated. Adding the bone stiffness and the shell stiffness using the equation for serial springs, one obtains a positive correlation between total stiffness and maximum deformation. DISCUSSION. The measured deformation values are within the same order of magnitude previously published [Lin 2006, Squire 2006]. The large variations of resulting maximum forces exhibit the need to further investigate shell deformation using commercial shell systems. The calculated bone stiffness at the point of the maximum deformation seems to be a valid predictor for expected shell deformation, but this also needs more data. A future goal is to determine expected shell deformation from bone data as a design rational


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 18 - 18
1 Nov 2021
Troiano E Facchini A Meglio MD Peri G Aiuto P Mondanelli N Giannotti S
Full Access

Introduction and Objective. In recent years, along with the extending longevity of patients and the increase in their functional demands, the number of annually performed RSA and the incidence of complications are also increasing. When a complication occurs, the patient often needs multiple surgeries to restore the function of the upper limb. Revision implants are directly responsible for the critical reduction of the bone stock, especially in the shoulder. The purpose of this paper is to report the use of allograft bone to restore the bone stock of the glenoid in the treatment of an aseptic glenoid component loosening after a reverse shoulder arthroplasty (RSA). Materials and Methods. An 86-years-old man came to our attention for aseptic glenoid component loosening after RSA. Plain radiographs showed a complete dislocation of the glenoid component with 2 broken screws in the neck of glenoid. CT scans confirmed the severe reduction of the glenoid bone stock and critical bone resorption and were used for the preoperative planning. To our opinion, given the critical bone defect, the only viable option was revision surgery with restoration of bone stock. We planned to use a bone graft harvested from distal bone bank femur as component augmentation. During the revision procedure the baseplate with a long central peg was implanted “on table” on the allograft and an appropriate osteotomy was made to customize the allograft on the glenoid defect according to the CT-based preoperative planning. The Bio-component was implanted with stable screws fixation on residual scapula. We decided not to replace the humeral component since it was stable and showed no signs of mobilization. Results. The new bio-implant was stable, and the patient gained a complete functional recovery of the shoulder. The scheduled radiological assessments up to 12 months showed no signs of bone resorption or mobilization of the glenoid component. Conclusions. The use of bone allograft in revision surgery after a RSA is a versatile and effective technique to treat severe glenoid bone loss and to improve the global stability of the implant. Furthermore, it represents a viable alternative to autologous graft since it requires shorter operative times and reduces graft site complications. There are very few data available regarding the use of allografts and, although the first studies are encouraging, further investigation is needed to determine the biological capabilities of the transplant and its validity in complex revisions after RSA


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 78 - 78
1 Nov 2021
Jolic M Shah FA Omar O Emanuelsson L Norlindh B Engqvist H Engstrand T Palmquist A Thomsen P
Full Access

Introduction and Objective. Calcium phosphates are among the most commonly used bone graft substitute materials. Compositions containing predominantly monetite (∼84.7%) with smaller additions of beta-tricalcium phosphate (β-TCP; ∼8.3%) and calcium pyrophosphate (Ca-PP; ∼6.8%) have previously been demonstrated to exhibit osteoinductive properties. Such a multi-component calcium phosphate bioceramic was fashioned in the form of hollowed-out, dome-shaped devices (15 mm diameter, 4 mm height), each reinforced with a 3D printed Ti6Al4V ELI frame. With the aim to induce bone formation beyond the skeletal envelope, these devices were investigated in vivo using a sheep (Ovis aries) occipital bone model. Materials and Methods. The bioceramic composition was prepared from a mixture of β-TCP/dicalcium pyrophosphate and monocalcium phosphate monohydrate powders mixed with glycerol. The Ti6Al4V ELI frame was positioned into a dome-shaped mould and bioceramic paste was poured over the frame and allowed to set, in sterile water, prior to removal from the mould. In adult female sheep (n=7), the devices were positioned directly over the bone and stabilised using self-drilling screws. After 52 weeks, the devices were retrieved, resin embedded, and used for X-ray micro-computed tomography (micro-CT), histology, backscattered electron scanning electron microscopy (BSE-SEM), energy dispersive X-ray spectroscopy (EDX), micro-Raman spectroscopy, and Fourier transform infrared spectroscopy (FTIR). Results. The bioceramic composition (Ca/P: ∼0.85 at. %) transforms to carbonated apatite (Ca/P: ∼1.2 at. %, Mg/Ca: ∼0.03 at. %), in vivo, largely at the expense of monetite and Ca-PP whereas β-TCP remains detectable. Discrete particles of Ca-PP are identified by correlative BSE-SEM and micro-Raman spectroscopy. Together with chemical transformation, physical degradation is evident within the bulk of the bioceramic. Beyond the confines of the skeletal envelope, de novo bone occupies ∼53–84% (∼73 ± 11%; mean ± standard deviation) of the hollowed-out space. Low porosity and the arrangement of remodelled bone into a concentric lamellar pattern is indicative of cortical-like structure. Such areas are typically surrounded by yet unremodelled, and microstructurally disordered, woven bone that stains intensely with blue cationic dyes, owing to relatively higher acid phosphate content. This pattern indicates a recurring sequence of woven bone formation followed by remodelling. Bone formation is also visible within the bioceramic. Recently remodelled and areas of ongoing remodelling are identified by relatively lower mineral density than the surrounding woven bone. Dendritic extensions of osteocytes appear to extend into the bioceramic surface. Both micro-Raman spectroscopy and FTIR reveal little, if any, detectable difference between the mineral and organic phases of the extracellular matrix, between de novo and native bone. Conclusions. The bioceramic composition undergoes physical degradation, but remains largely intact by 52 weeks in vivo, and only partially transforms to carbonated apatite. In addition to very high bone volume within the hollowed-out bioceramic device, the overall composition and microstructure of de novo bone are similar to native bone. Notably, the mineral phase of bone in response to, and in direct contact with the β-TCP, monetite, and Ca-PP, remains exclusively carbonated apatite


Bone & Joint Open
Vol. 4, Issue 4 | Pages 250 - 261
7 Apr 2023
Sharma VJ Adegoke JA Afara IO Stok K Poon E Gordon CL Wood BR Raman J

Aims. Disorders of bone integrity carry a high global disease burden, frequently requiring intervention, but there is a paucity of methods capable of noninvasive real-time assessment. Here we show that miniaturized handheld near-infrared spectroscopy (NIRS) scans, operated via a smartphone, can assess structural human bone properties in under three seconds. Methods. A hand-held NIR spectrometer was used to scan bone samples from 20 patients and predict: bone volume fraction (BV/TV); and trabecular (Tb) and cortical (Ct) thickness (Th), porosity (Po), and spacing (Sp). Results. NIRS scans on both the inner (trabecular) surface or outer (cortical) surface accurately identified variations in bone collagen, water, mineral, and fat content, which then accurately predicted bone volume fraction (BV/TV, inner R. 2. = 0.91, outer R. 2. = 0.83), thickness (Tb.Th, inner R. 2. = 0.9, outer R. 2. = 0.79), and cortical thickness (Ct.Th, inner and outer both R. 2. = 0.90). NIRS scans also had 100% classification accuracy in grading the quartile of bone thickness and quality. Conclusion. We believe this is a fundamental step forward in creating an instrument capable of intraoperative real-time use. Cite this article: Bone Jt Open 2023;4(4):250–261


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 18 - 18
1 Mar 2021
Babel H Omoumi P Jolles B Favre J
Full Access

While knee osteoarthritis (OA) is now recognized as a complex disease affecting the whole joint, not just the cartilages, there remains a paucity of data regarding the interactions between knee components. One relationship of particular interest is between the spatial variations in cartilage thickness (CTh) and subchondral bone mineral density (BMD). Indeed, bone and cartilage are two mechanosensitive tissues that interact as a functional unit and there is evidence of a biomechanical coupling between both tissues. Particularly, a recent in vivo study has shown a positive relationship in non-OA knees with thicker cartilage where bone is denser, and an alteration of this relationship in OA knees. These observations support the concept of an osteochondral unit and warrant additional research to assess the influence of bone depth. Therefore, this study aimed to characterize the relationship between spatial variations in CTh and BMD measured at various depths below the bone surface. CT-arthrography of 20 non-OA tibias and 20 severe medial-compartment OA tibias were segmented to build 3D mesh models of the bones and cartilages. Each individual tibia model was registered to a reference tibia, allowing to calculate BMD maps at 1, 3, 5 and 10mm below the bone-cartilage interface in the medial compartment. Pearson correlations between CTh maps and the four BMD maps were then calculated for each knee. Lastly, differences in correlation coefficients between successive bone layers were assessed using Wilcoxon signed-rank tests. In both OA and non-OA tibias, the correlation coefficients were higher with the BMD measured in the 1mm layer, and followed a pattern of statistically significant decrease with bone layers of increasing depth (p < 0.021). In non-OA tibias, the median relationship was positive with a strong effect size in the 1, 3 and 5mm layers, while in OA tibias the median relationship was positive only in the 1mm layer and with a medium effect size. In the OA tibias, the median relationship was negative with a weak effect size in the 3 and 5mm layers, and it was negative with a medium effect size in the 10mm layer. In conclusion, the results of the present study support the value of considering bone and cartilage as a unit, and more generally support OA pathophysiology models based on relationships among knee properties


Bone & Joint Open
Vol. 4, Issue 7 | Pages 516 - 522
10 Jul 2023
Mereddy P Nallamilli SR Gowda VP Kasha S Godey SK Nallamilli RR GPRK R Meda VGR

Aims. Musculoskeletal infection is a devastating complication in both trauma and elective orthopaedic surgeries that can result in significant morbidity. Aim of this study was to assess the effectiveness and complications of local antibiotic impregnated dissolvable synthetic calcium sulphate beads (Stimulan Rapid Cure) in the hands of different surgeons from multiple centres in surgically managed bone and joint infections. Methods. Between January 2019 and December 2022, 106 patients with bone and joint infections were treated by five surgeons in five hospitals. Surgical debridement and calcium sulphate bead insertion was performed for local elution of antibiotics in high concentration. In all, 100 patients were available for follow-up at regular intervals. Choice of antibiotic was tailor made for each patient in consultation with microbiologist based on the organism grown on culture and the sensitivity. In majority of our cases, we used a combination of vancomycin and culture sensitive heat stable antibiotic after a thorough debridement of the site. Primary wound closure was achieved in 99 patients and a split skin graft closure was done in one patient. Mean follow-up was 20 months (12 to 30). Results. Overall, six out of 106 patients (5.6%) presented with sepsis and poorly controlled comorbid conditions, and died in the hospital within few days of index surgery. Out of the remaining 100 patients, control of infection was achieved in 95 patients (95%). Persistence of infection was noted in five (5%) patients. Out of these 95 patients that had good control of infection, four patients (4.2%) with gap nonunion needed Masquelet procedure to achieve union. Conclusion. Our multicentre experience confirmed that surgical debridement along with calcium sulphate bead insertion was effective in treating bone and joint infections without any side effects and complications. Cite this article: Bone Jt Open 2023;4(7):516–522