Abstract. Background. The Oxford Domed Lateral (ODL) Unicompartmental Knee Replacement (UKR) has some advantages over other lateral UKRs, but the mobile
Aims. Medial unicompartmental knee arthroplasty (mUKA) is an advised treatment for anteromedial knee osteoarthritis. While long-term survival after mUKA is well described, reported incidences of short-term surgical complications vary and the effect of surgical usage on complications is less established. We aimed to describe the overall occurrence and treatment of surgical complications within 90 days of mUKA, as well as occurrence in high-usage centres compared to low-usage centres. Methods. mUKAs performed in eight fast-track centres from February 2010 to June 2018 were included from the Lundbeck Foundation Centre for Fast-track Hip and Knee Replacement Database. All readmissions within 90 days of surgery underwent chart review and readmissions related to the surgical wound or the prosthesis were recorded. Centres were categorized as high-usage centres when using mUKA in ≥ 20% of annual knee arthroplasties. The occurrence of complications between high- and low-usage centres were compared using Fisher’s exact test. Results. We included 3,757 mUKAs: 2,377 mUKAs from high-usage centres and 1,380 mUKAs from low-usage centres. Surgical complications within 90 days occurred in 69 cases (1.8%), 45 (1.9%) in high-usage centres and 24 (1.7%) in low-usage centres (odds ratio (OR) 1.1 (95% confidence interval (CI) 0.65 to 1.8)). The most frequent complications were periprosthetic joint infections (PJIs) (n = 18; 0.48%), wound-related issues (n = 14; 0.37%), and periprosthetic fractures (n = 13; 0.35%).
Discussion: This study has shown a high dislocation rate for a COP bearing that was reduced to a low dislocation rate by changing the bearing surface to a MOM design. A potential mechanism for this may be the ‘suction fit’ from the surface tension of the low clearance, high tolerance that the metal-on-metal bearing possesses, requiring increased torque to dislocate during impingement.
Source of the study: University of Auckland, Auckland, New Zealand. Unicompartmental knee arthroplasty (UKA) is effective for patients with isolated compartment osteoarthritis, however the procedure has higher revision rates. Long-term survivorship and accurate characterisation of revision reasons are limited by a lack of long-term data and standardised revision definitions. We aimed to identify survivorship, risk factors and revision reasons in a large UKA cohort with up to 20 years follow-up. Patient, implant and revision details were recorded through clinical and radiological review for 2,137 consecutive patients undergoing primary medial UKA across Auckland, Canterbury, Counties Manukau and Waitematā DHB between 2000 and 2017. Revision reasons were determined from review of clinical, laboratory, and radiological records for each patient using a standardised protocol. To ensure complete follow-up data was cross-referenced with the New Zealand Joint Registry to identify patients undergoing subsequent revision outside the hospitals. Implant survival, revision risk and revision reasons were analysed using Cox proportional-hazards and competing risk analyses. Implant survivorship at 15 years was comparable for cemented fixed-bearing (cemFB; 91%) and uncemented mobile-bearing (uncemMB; 91%), but lower for cemented mobile-bearing (cemMB; 80%) implants. There was higher incidence of aseptic loosening with cemented implants (3–4% vs. 0.4% uncemented, p<0.01), osteoarthritis (OA) progression with cemMB implants (9% vs. 3% cemFB/uncemMB; p<0.05) and
Cementless fixation is an alternative to cemented unicompartmental knee replacement (UKR), with several advantages over cementation. This study reports on the 15-year survival and 10-year clinical outcomes of the cementless Oxford unicompartmental knee replacement (OUKR). This prospective study describes the clinical outcomes and survival of first 693 consecutive cementless medial OUKRs implanted in New Zealand. The sixteen-year survival was 89.2%, with forty-six knees being revised. The commonest reason for revision was progression of arthritis, which occurred in twenty-three knees, followed by primary dislocation of the bearing, which occurred in nine knees. There were two
Source of the study: University of Auckland, Auckland, New Zealand and University of Otago, Christchurch, New Zealand. Patient reported outcome measures (PROMs) are predictors of knee arthroplasty revision. Unicompartmental knee arthroplasty (UKA) is effective for patients with the correct indications, however has higher revision rates than total knee arthroplasty (TKA). Different revision thresholds for the procedures have been postulated. Our aims were to investigate: 1) if PROMs could predict knee arthroplasty revision within two years of the score at six months, five years and ten years follow-up, and 2) if revision ‘thresholds’ differed between TKA and UKA. All TKAs and UKAs captured by the New Zealand Joint Registry between 1999 and 2019 with at least one OKS response at six months (TKA n=27,708, UKA n=8,415), five years (TKA n=11,519, UKA n=3,365) or ten years (TKA n=6,311, UKA n=1,744) were included. were propensity-score matched 2:1 with UKAs for comparison of revision thresholds. Logistic regression indicated that for every one-unit decrease in OKS, the odds of TKA and UKA revision decreased by 10% and 11% at six months, 10% and 12% at five years and 9% and 5% at ten years. Fewer TKA patients with ‘poor’ outcomes (≤25) subsequently underwent revision compared with UKA at six months (5.1% vs. 19.6%, p<0.001), five years (4.3% vs. 12.5%, p<0.001) and ten years (6.4%vs. 15.0%, p=0.02). Compared with TKA, UKA patients were 2.5 times more likely to undergo revision for ‘unknown’ reasons,
Introduction: The results of the mobile bearing Oxford partial knee replacement (PKR) in the lateral compartment have been disappointing with a five year survival of 82%.
Oxford Medial Unicompartmental Knee Replacement (OMUKR) is a well-established treatment option for isolated medial compartment arthritis, with good patient reported outcome measures (PROMs). We present our results of the Oxford Domed Lateral Unicompartmental Knee Replacement (ODLUKR) to establish if patients benefit as much as with OMUKR. Retrospective review of prospectively collected data of a single surgeon series of consecutive UKR from 2007 to 2014 were collated with a minimum 2 years follow-up. PROMs data were collected using pre- and post-operative Oxford Knee Scores (OKS) (best score of 48). One hundred and twenty-eight OMUKR and 27 ODLUKR were performed in the study period. There was no significant difference in the age at time of surgery, but there were significantly more women in the ODLUKR group (74% vs 53%). There was no significant difference in pre-op OKS between the groups (OMUKR = 16/48; ODLUKR = 20/48), or the improvement in OKS post-op (OMUKR = 19 points; ODLUKR = 17 points). One ODLUKR was revised to Total Knee Replacement (TKR) for pain. There were three (11.1%)
Introduction. The results of the original mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing because of high dislocation rates (11%). This original implant used a flat bearing articulation on the tibial tray. To address the issue of dislocation a new implant (domed tibia with biconcave bearing to increase entrapment) was introduced with a modified surgical technique. The aim of this study was to compare the risk of dislocation between a domed and flat lateral UKR. Methods. Separate geometric computer models of an Oxford mobile bearing lateral UKR were generated for the two types of articulation between the tibial component and the meniscal bearing: Flat-on-flat (flat) and Concave-on-convex (domed). Each type of mobile bearing was used to investigate three distinct dislocation modes observed clinically: lateral to medial dislocation, with the bearing resting on the tray wall (L-M-Wall); medial to lateral dislocation, out of the joint space (M-L); anterior to posterior dislocation, out of the joint space (A-P). A size C tray and a medium femoral component and bearing were used in all models. The femoral component, tibial tray and bearing were first aligned in a neutral position. For each dislocation the tibial tray was restrained in all degrees of freedom. The femoral component was restrained from moving in the anterior-posterior directions and in the medial-lateral directions. The femoral component was also restrained from rotating about the anterior-posterior, medial-lateral and superior-inferior directions. This meant that the femoral component was only able to move in the superior-inferior direction. Different bearing sizes were inserted into the model and the effect that moving the femoral component medially and laterally had on the amount of distraction required to cause
Background. To evaluate the causes and modes of complications after unicompartmental knee arthroplasty (UKA), and to identify its prevention and treatment method by analyzing the complications after UKA. Materials and Methods. A total of 1,576 UKAs were performed between January 2002 and December 2014 at a single-institution. Postoperative complications occurred in 89 knees (83 patients, 5.6%), and 86 of them were found in females and 3 in males. Their mean age was 61 years (range, 46 to 81 years) at the time of initial UKA and 66 years (range, 46 to 82 years) at the time of revision surgery. We analyzed the complications after UKA retrospectively andinvestigated the proper methods of treatment (Table 1). Results. A total of 89 complications (5.6%) occurred afterUKA. Regarding the type of complications after UKA, there were
Purpose. Unicompartmental Knee Arthroplasty (UKA) has been indicated for inactive elderly patients over 60, but for young and active patients less than 60 years old, it has been regarded as a contraindication. The purpose of this study is to evaluate the usefulness of UKA performed on young Asian patients under 60 years of age by analyzing clinical outcomes, complications and survival rate. Materials and Methods. The subjects were 82 cases, which were followed up for at least 5 years (from 5 to 12 years). Only Oxford phase III® (Biomet Orthopedics, Inc, Warsaw, USA) prosthesis was used for all cases. The clinical evaluation was done by the range of motion, Knee society score (KSS), WOMAC score. The radiographic evaluation was performed on weight bearing long-leg radiographs, AP and lateral view of the knee and skyline view of the patella. The survival rate was estimated by Kaplan-Meier survival analysis. Results. Three
The Oxford unicompartmental knee replacement (UKR) was introduced in 1976 with good results. Mobile bearings in the lateral compartment have been associated with unacceptably high
Introduction. The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of
Introduction: The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of
Aims. The aim of this to study was to compare the previously unreported
long-term survival outcome of the Oxford medial unicompartmental
knee arthroplasty (UKA) performed by trainee surgeons and consultants. . Patients and Methods. We therefore identified a previously unreported cohort of 1084
knees in 947 patients who had a UKA inserted for anteromedial knee
arthritis by consultants and surgeons in training, at a tertiary
arthroplasty centre and performed survival analysis on the group
with revision as the endpoint. Results. The ten-year cumulative survival rate for revision or exchange
of any part of the prosthetic components was 93.2% (95% confidence
interval (CI) 86.1 to 100, number at risk 45). Consultant surgeons
had a nine-year cumulative survival rate of 93.9% (95% CI 90.2 to
97.6, number at risk 16). Trainee surgeons had a cumulative nine-year
survival rate of 93.0% (95% CI 90.3 to 95.7, number at risk 35).
Although there was no differences in implant survival between consultants
and trainees (p = 0.30), there was a difference in failure pattern
whereby all re-operations performed for
When the Oxford unicompartmental meniscal bearing arthroplasty (UCA) is used in the lateral compartment of the knee 10% of the bearings dislocate. An in-vitro cadaveric study was performed to investigate if the anatomy and joint geometry of the lateral compartment was a contributory factor in
The aim of this study was to describe the pattern of revision indications for unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) and any change to this pattern for UKA patients over the last 20 years, and to investigate potential associations to changes in surgical practice over time. All primary knee arthroplasty surgeries performed due to primary osteoarthritis and their revisions reported to the Danish Knee Arthroplasty Register from 1997 to 2017 were included. Complex surgeries were excluded. The data was linked to the National Patient Register and the Civil Registration System for comorbidity, mortality, and emigration status. TKAs were propensity score matched 4:1 to UKAs. Revision risks were compared using competing risk Cox proportional hazard regression with a shared γ frailty component.Aims
Methods
Background. A commonly held belief amongst surgeons and patients is that progression of disease (arthritis) to other compartments is a major cause of early failure of UKRs. Methods. We analysed the NJR database records of 17,643 primary UKRs performed between April 2003 and April 2009. Where these had been revised the reason for revision was noted. Results. Of the 17,643 primary UKRs, 308 had died and were excluded from the analysis. Of the living, 505 had been revised (3%) at a mean 3.45 years (range 2-6 years) following the primary procedure. Reason for revision was recorded in 472 cases (93%). Aseptic loosening was the commonest cause for revision in 154 cases (33%), followed by non specific pain in 129 cases (27%),
The results of mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing (five-year survival: 82%). Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to a high dislocation rate. A detailed analysis confirmed the elevated lateral tibial joint line to be a contributory factor to
The aim was to identify frequency and pattern of early UKR failure in New Zealand. We analysed data from the New Zealand National Joint Register in a 44 month period of 2000–2003. Thirty-five percent of the 1790 registered UKRs were performed in the last 8 months [ie. in 18% of the total time period]. The ratio of UKRs to TKRs performed was 1:6.25. Fifty two revisions meant a failure rate of 2.9% for UKR (n=1790) compared with 1.6% for TKR (n=11243). The most commonly used implants were the Oxford P3 (68% of total with 2.2% revision rate), MG uni (14.6% with 4.6% revision rate) and Preservation (7% with 5.6 revision rate). The most common reasons for revision (n=52) were aseptic loosening (28%),