Aims. To systematically review the efficacy of split tendon transfer surgery on gait-related outcomes for children and adolescents with cerebral palsy (CP) and spastic equinovarus foot deformity. Methods. Five databases (CENTRAL, CINAHL, PubMed, Embase, Web of Science) were systematically screened for studies investigating split tibialis anterior or split tibialis posterior tendon transfer for spastic equinovarus foot deformity, with gait-related outcomes (published pre-September 2022). Study quality and evidence were assessed using the Methodological Index for Non-Randomized Studies, the Risk of Bias In Non-Randomized Studies of Interventions, and the Grading of Recommendations Assessment, Development and Evaluation. Results. Overall, 17 studies (566 feet) were included: 13 studies used clinical grading criteria to report a postoperative ‘success’ of 87% (75% to 100%), 14 reported on orthotic use with 88% reduced postoperative use, and one study reported on
Sag. Ankle Angle ROM (standard): 14,31 4,72 *(OP); 28,39 4,96(healthy) Sag. Ankle Angle ROM (footmodel): 9,36 2,62 *(OP); 18,68 4,33 Sag. Med Arch ROM: 12,85 4,85 * (OP); 20,11 4,71 Front. Subtalar Inversion ROM: 4,59 1,44 *(OP); 7,56 1,96 Front. Forefoot Ankle Supination ROM: 10,23 3,71 *(OP); 13,91 3,82 (Mean standard deviation; * statistical significance from healthy side p<
0.01)
Abstract. Skeletal kinematics are traditionally measured by motion analysis methods such as optical motion capture (OMC). While easy to carry out and clinically relevant for certain applications, it is not suitable for analysing the ankle joint due to its anatomical complexity. A greater understanding of the function of healthy ankle joints could lead to an improvement in the success of ankle-replacement surgeries. Biplane video X-ray (BVX) is a technique that allows direct measurement of individual bones using highspeed, dynamic X-Rays. Objective. To develop a protocol to quantify in-vivo foot and
To be able to assess the biomechanical and functional effects of ankle injury and disease it is necessary to characterise healthy
Abstract. Objectives. The syndesmosis joint, located between the tibia and fibula, is critical to maintaining the stability and function of the ankle joint. Damage to the ligaments that support this joint can lead to ankle instability, chronic pain, and a range of other debilitating conditions. Understanding the kinematics of a healthy joint is critical to better quantify the effects of instability and pathology. However, measuring this movement is challenging due to the anatomical structure of the syndesmosis joint. Biplane Video Xray (BVX) combined with Magnetic Resonance Imaging (MRI) allows direct measurement of the bones but the accuracy of this technique is unknown. The primary objective is to quantify this accuracy for measuring tibia and fibula bone poses by comparing with a gold standard implanted bead method. Methods. Written informed consent was given by one participant who had five tantalum beads implanted into their distal tibia and three into their distal fibula from a previous study. Three-dimensional (3D) models of the tibia and fibula were segmented (Simpleware Scan IP, Synopsis) from an MRI scan (Magnetom 3T Prisma, Siemens). The beads were segmented from a previous CT and co-registered with the MRI bone models to calculate their positions. BVX (125 FPS, 1.25ms pulse width) was recorded whilst the participant performed level gait across a raised platform. The beads were tracked, and the bone position of the tibia and fibula were calculated at each frame (DSX Suite, C-Motion Inc.). The beads were digitally removed from the X-rays (MATLAB, MathWorks) allowing for blinded image-registration of the MRI models to the radiographs. The mean difference and standard deviation (STD) between bead-generated and image-registered bone poses were calculated for all degrees of freedom (DOF) for both bones. Results. The absolute mean tibia and fibula bone position differences (Table 1) between the bead and BVX poses were found to be less than 0.5 mm for both bones. The bone rotation differences were found to be less than 1° for all axes except for the fibula Z axis rotation which was found to be 1.46°. One study. 1. has reported the kinematics of the syndesmosis joint and reported maximum ranges of motion of 9.3°and translations of 3.3mm for the fibula. The results show that the accuracy of the methodology is sufficient to quantify these small movements. Conclusions. BVX combined with MRI can be used to accurately measure the syndesmosis joint. Future work will look at quantifying the accuracy of the talus to provide further understanding of normal
Nearly one quarter of ankle fractures have a recognized syndesmosis injury. An intact syndesmosis ligament complex stabilizes the distal tibio-fibular joint while allowing small, physiologic amounts of relative motion. When injured, malreduction of the syndesmosis has been found to be the most important independent factor that contributes to inferior functional outcomes. Despite this, significant variability in surgical treatment remains. This may be due to a poor understanding of normal dynamic syndesmosis motion and the resultant impact of static and dynamic fixation on post-injury syndesmosis kinematics. As the syndesmosis is a dynamic structure, conventional CT static images do not provide a complete picture of syndesmosis position, giving potentially misleading results. Dynamic CT technology has the ability to image joints in real time, as they are moved through a range-of-motion (ROM). The aim of this study was to determine if syndesmosis position changes significantly throughout ankle range of motion, thus warranting further investigation with dynamic CT. This is an a priori planned subgroup analysis of a larger multicentre randomized clinical trial, in which patients with AO-OTA 44-C injuries were randomized to either Tightrope or screw fixation. Bilateral ankle CT scans were performed at 1 year post-injury, while patients moved from maximal dorsiflexion (DF) to maximal plantar flexion (PF). In the uninjured ankles, three measurements were taken at one cm proximal to the ankle joint line in maximal DF and maximal PF: Anterior (ASD), middle (MSD), and posterior (PSD) syndesmosis distance, in order to determine normal syndesmosis position. Paired samples t-tests compared measurements taken at maximal DF and maximal PF. Twelve patients (eight male, six female) were included, with a mean age of 44 years (±13years). The mean maximal DF achieved was 1-degree (± 7-degrees), whereas the mean maximal PF was 47-degrees (± 8-degrees). The ASD in DF was 3.0mm (± 1.1mm) versus 1.9mm (± 0.8mm) in PF (p<0.01). The MSD in DF was 3.3mm (±1.1mm) versus 2.3mm (±0.9mm) in PF (p<0.01). The PSD in DF was 5.3mm (±1.5mm) versus 4.6mm (±1.9mm) in PF (p<0.01). These values are consistent with the range of normal parameters previously reported in the literature, however this is the first study to report the ankle position at which these measurements are acquired and that there is a significant change in syndesmosis measurements based on ankle position. Normal syndesmosis position changes in uninjured ankles significantly throughout range of motion. This motion may contribute to the variation in normal anatomy previously reported and controversies surrounding quantifying anatomic reduction after injury, as the ankle position is not routinely standardized, but rather static measurements are taken at patient-selected ankle positions. Dynamic CT is a promising modality to quantify normal
INTRODUCTION. Proper ligament engagement is an important topic of discussion for total knee arthroplasty; however, its importance to total ankle arthroplasty (TAA) is uncertain. Ligaments are often lengthened or repaired in order to achieve balance in TAA without an understanding of changes in clinical outcomes. Unconstrained designs increase ankle laxity,. 1. but little is known about ligament changes with constrained designs or throughout functional activity. To better understand the importance of ligament engagement, we first investigated the changes in distance between ligament insertions throughout stance with different TAA designs. We hypothesize that the distance between ligaments spanning the ankle joint would increase in specimens following TAA throughout stance. METHODS. A validated method of measuring individual bone kinematics was performed on pilot specimens pre- and post-TAA using a six-degree-of-freedom robotic simulator with extrinsic muscle actuators and motion capture cameras (Figure 1). 2. Reflective markers attached to surgical pins and radiopaque beads were rigidly fixed to the tibia, fibula, talus, calcaneus, and navicular for each specimen. TAAs were performed by a fellowship-trained foot and ankle surgeon on two specimens with separate designs implanted (Cadence & Salto Talaris; Integra LifeSciences; Plainsboro, NJ). Each specimen was CT-scanned after robotic simulations of stance pre- and post-TAA. Specimens were then dissected before a 3D-coordinate measuring device was used to digitize the ligament insertions and beads. Ligament insertions were registered onto the bone geometries within CT images using the digitized beads. Individual bone kinematics measured from motion capture were then used to record the point-to-point distance between centers of the ligament insertions throughout stance. RESULTS. Results from the pilot specimens are presented for the calcaneofibular ligament (CFL) only. The distance between the CFL insertions was larger throughout stance following Cadence implantation (Figure 2A) and was decreased throughout most of stance following Salto Talaris implantation (Figure 2B). The percent change in CFL distance with respect to static standing was also increased with the Cadence implant (Figure 2C) and similar to intact following Salto Talaris implantation (Figure 2D). Ankle motion was similar to intact with the Cadence (Figure 3A) and was decreased with the Salto Talaris (Figure 3B). DISCUSSION. This study suggests that ligament length during stance changes following TAA. The Cadence implant similarly replicated
Total ankle replacement (TAR) is a substitute to ankle fusion, replacing the degenerated joint with a mechanical motion-conserving alternative. Compared with hip and knee replacements, TARs remain to be implanted in much smaller numbers, due to the surgical complexity and low mid-to-long term survival rates. TAR manufacturers have recently explored the use of varying implant sizes to improve TAR performance. This would allow surgeons a wider scope for implanting devices for varying patient demographics. Minimal pre-clinical testing has been demonstrated to date, while existing wear simulation standards lack definition. Clinical failure of TARs and limited research into wear testing defined a need for further investigation into the wear performance of TARs to understand the effects of the kinematics on varying implant sizes. Six medium and six extra small BOX® (MatOrtho) TARs will be tested in a modified knee simulator for 5 million cycles (Mc). The combinations of simulator inputs that mimic natural gait conditions were extracted from
Abstract. Background. Proximal fibular osteotomy (PFO) was defined to provide a treatment option for knee pain caused by gonarthrosis(1). Minor surgical procedure, low complication rate and dramatic pain relief were the main reasons for popularization of this procedure(2, 3). However, changes at the knee and ankle joint after PFO were not clarified objectively in the literature. Questions/purposes. We asked: 1) Does PFO change the maximum and average pressures at the medial and lateral chondral surface of the tibia plateau? 2) Are chondral surface stresses redistributed at the knee and ankle joint after PFO? 3)Does PFO change the distribution of total load on the knee joint? 4) Can PFO lead to change in alignment of lower limb?. Methods. This study was conducted at Maltepe University Faculty of Medicine Hospital, Orthopedics and Traumatology Department and Yildiz Technical University Mechanical Engineering Department in Istanbul, Turkey, between September 2019 and February 2020. Finite element analysis (FEA) was used to evaluate effects of PFO(4). One 62 years old, female volunteer's X-ray, computer tomography and magnetic resonance imaging images were used for creating right lower limb model. Two different lower limb models were created. One of them was osteotomized model (OM) which was created according to definition of PFO and the other was non-osteotomized model (NOM). To obtain a stress distribution comparison between the two models, 350 N of axial force was applied to the femoral heads of the models. Results. After PFO, the maximum contact pressures at the medial and lateral tibial cartilages decreased 83.2% and 66.9%, respectively at the knee joint. The average contact pressure decreased 26.1% at the medial tibial cartilage and increased 42.4% at the lateral tibial cartilage. The Von Mises stresses decreased 57.1% at the femoral cartilage and decreased 79.1% at tibial cartilage. The stress on the tibial cartilage increased 44.6%, and stress on the talar cartilage increased 7.1% at the ankle joint. Under a 350 N axial force, distribution of the total load at the knee joint was changed and become more homogenous in OM compared to NOM. Change in lower extremity alignment after PFO could not be evaluated with FEA. Conclusion. FEA revealed that PFO causes some changes in knee and
Purpose. The goal of Total Ankle Arthroplasty (TAA) is to relieve pain and restore healthy function of the intact ankle. Restoring intact
Purpose of Study. In children with spastic diplegia, surgery for equinus has a high incidence of both over and under correction. We wished to determine if conservative (mainly Zone 1) surgery for equinus gait, in the context of multilevel surgery, could result in the avoidance of calcaneus and crouch gait as well as an acceptable rate of recurrent equinus, at medium term follow-up. Description of Methods. This was a retrospective, consecutive cohort study of children with spastic diplegia, between 1996 and 2006. All children had distal gastrocnemius recession or differential gastrocsoleus lengthening, on one or both sides, as part of Single Event Multilevel Surgery. The primary outcome measures were the Gait Variable Scores (GVS) and Gait Profile Score (GPS) at two time points after surgery. Summary of Results. Forty children with spastic diplegia, GMFCS Level II and III were eligible for inclusion in this study. There were 25 boys and 15 girls, mean age 10 years at surgery. The mean age at final follow-up was 17 years and the mean postoperative follow-up period was seven years. The mean ankle GVS improved from 18.5° before surgery to 8.7° at short term follow-up (P<0.005) and 7.8° at medium term follow-up. Equinus gait was successfully corrected in the majority of children with a low rate of over-correction (2.5%) but a high rate of recurrent equinus (35.0%), as determined by sagittal
Introduction:. There is paucity of literature on Gait analysis following Total Ankle Replacement (TAR). We aimed to study changes to gait after successful Mobility TAR. Methods:. 20 patients who underwent a primary TAR, with a diagnosis of either OA or PTOA were recruited between October 2008 and March 2011. Gait analysis was carried out using the Helen Hayes marker system with VICON 3D opto-electric system pre-operatively, 3, 6 and 12 months post-operatively.
The results of the Baumann procedure (intramuscular lengthening of the gastrocnemius and soleus in the proximal part of the muscle) for correction of fixed gastrosoleus contracture in diplegic children are presented. Eleven ambulatory children with diplegic type of cerebral palsy (mean age: 10 years) were operated for correction of fixed gastrosoleus contracture by the Baumann procedure as part of a multi-level, single-session surgery for gait improvement. Evaluation included clinical examination and gait analysis. Mean follow-up after surgery was 2.7 years. Clinical examination demonstrated significant improvements in active and passive ankle dorsal flexion with maintenance of ankle plantar flexor power.
Purpose: To compare gait kinematics and kinetics in five-year old children treated initially with Ponseti casting versus French physical therapy. A third group, consisting of patients initially treated with these non-operative methods and then undergoing surgery consisting of more than a tendoachilles lengthening, was compared to those children treated entirely non-operatively. Method: Ninety patients (125 clubfeet) were tested at age five years. Thirty-four feet had undergone only Ponseti treatment, 40 the French program, and 51 had initial non-operative treatment with either the Ponseti or French protocols but later had surgery at an average age of 2+3 years. Kinematics and kinetics were compared to age-matched normal subjects. Results: Average stance-phase dorsiflexion did not differ between groups or from normal. Incidence of equinus: French 5%, Ponseti 0%; Increased stance-phase dorsiflexion: French 3%, Ponseti 24%, Surgical 18% (p <
0.05). A similar number of feet that were not operated upon at age five had in-toeing: 30% French, 32% Ponseti. Decreased ankle power generation at push-off: 53% French; 47% Ponseti; 67% Surgical. Average ankle power generation: 2.21 W/kg French, 2.36 W/kg Ponseti, 1.97 W/kg Surgical (2.83 W/kg in normal 5-year-old children). There was a difference in ankle power generation between normal feet and both the French and surgical groups (p<
0.001). Feet in the non-operative groups that had undergone Achilles tenotomy (n=28) had similar ankle power to those feet (n=42) that did not have tenotomies (p =0.223). Hip power generation was increased 33% in children who had undergone Ponseti treatment (1.38 W/kg), and 41% after French nonoperative treatment (1.47 W/kg), compared to normal (1.04 W/kg). This may be to compensate for poor ankle push-off. Conclusion: The gait characteristics of those feet that have not had surgery reveal that the majority had normal
Testing of cadaver ankle specimens was conducted to investigate the changes in kinematics with lateral ligament reconstructions. Testing included an intact condition, after injury at the ATFL and CFL sites, and separately a Brostrom repair and an anatomical gracil-lis graft reconstruction. Calcaneal range of motion was determined about the axis of applied moment in plantarflexion-dorsiflexion and in inversion-eversion directions. The injury and reconstructions were most sensitive during IE applied moment. Both reconstructions appeared to behave similar to intact motion. Failure of some Brostrom repairs however, suggest that the gracillis-graft reconstruction is initially a stronger repair. Limited research has biomechanically investigated lateral ankle ligament reconstruction procedures. The objective of this study was to determine the changes in
Restoration of natural range and pattern of motion is the primary goal of joint replacement. In total ankle replacement, proper implant positioning is a major requirement to achieve good clinical results and to prevent instability, aseptic loosening, meniscal bearing premature wear and dislocation at the replaced ankle. The current operative techniques support limitedly the surgeon in achieving a best possible prosthetic component alignment and in assessing proper restoration of ligament natural tensioning, which could be well aided by computer-assisted surgical systems. Therefore the outcome of this replacement is, at present, mainly associated to surgeon's experience and visual inspection. In some of the current ankle prosthetic designs, tibial component positioning along the anterior/posterior (A/P) and medio/lateral axes is critical, particularly in those designs not with a flat articulation between the tibial and the meniscal or talar components. The general aim of this study was assessing in-vitro the effects of the A/P malpositioning of the tibial component on three-dimensional kinematics of the replaced joint and on tensioning of the calcaneofibular (CaFiL) and tibiocalcaneal (TiCaL) ligaments, during passive flexion. Particularly, the specific objective is to compare the intact
The August 2013 Children’s orthopaedics Roundup360 looks at: a multilevel approach to equinus gait; whether screening leads to needless intervention; salvage of subcapital slipped epiphysis; growing prostheses for children’s oncology; flexible nailing revisited; ultrasound and the pink pulseless hand; and slipping forearm fractures.