Current treatment options for displaced acetabular fractures in elderly patients include non-surgical management, surgical fixation and surgical fixation with simultaneous hip replacement, the so-called “fix-and-replace”™. There remains a paucity of evidence to guide surgeons in decision making for these difficult injuries. The aim of this study was to assess the feasibility of performing an appropriately powered RCT between treatment options for acetabular fractures in older patients. This was an NIHR funded feasibility triple-arm RCT with participation from 7 NHS MTCs. Patients older than 60 were recruited if they had an acetabular fracture deemed sufficiently displaced for the treating surgeon to consider surgical fixation. Randomisation was performed on a 1:1:1 basis. The three treatment arms were non-surgical management, surgical fixation and fix-and-replace. Feasibility was assessed by willingness of patients to participate and clinicians to recruit, drop out rate, estimates of standard deviation to inform the sample size calculation for the full trial and completion rates to inform design of a future definitive trial. EQ-5D was the primary outcome measure at 6 months, OHS and Disability Rating Index were secondary outcome measures. Of 117 eligible patients, 60 were randomised whilst 50 declined study participation. Nine patients did not receive their allocated intervention. Analysis was performed on an intention to treat basis. During the study period 4 patients withdrew before final review, 4 patients died and 1 was lost to follow-up. The estimated sample size for a full scale study was calculated to be 1474 participants for an EQ-5D MCID of 0.06 with a power of 0.8. This feasibility study suggests a full scale trial would require international collaboration. This study also has provided observed safety data regarding mortality and morbidity for the fix-and-replace procedure to
Preoperative ligament laxity can be characterized intraoperatively using digital robotic tensioners. Understanding how preoperative knee joint laxity affects preoperative and early post-operative patient reported outcomes (PROMs) may
Introduction. There is debate regarding whether the use of computer-assisted technology, such as navigation and robotics, has any benefit on clinical or patient reported outcomes following total knee arthroplasty (TKA). This study aims to report on the association between intraoperative use of technology and outcomes in patients who underwent primary TKA. Methods. We retrospectively reviewed 7,096 patients who underwent primary TKA from 2016–2020. Patients were stratified depending on the technology utilized intraoperatively: navigation, robotics, or no technology. Patient demographics, clinical data, Forgotten Joint Score-12 (FJS), and Knee injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR) were collected at various time points up to 1-year follow-up. Demographic differences were assessed with chi-square and ANOVA tests. Clinical data and mean FJS and KOOS, JR scores were compared using univariate ANCOVA, controlling for demographic differences. Results. During the study period, 287 (4%) navigation, 367 (5%) robotics, and 6,442 (91%) manual cases were performed. Surgical time significantly differed between the three groups (113.33 vs. 117.44 vs. 102.11 respectively; p<0.001). Discharge disposition significantly differed between the three groups (p<0.001), with a greater percentage of patients who underwent manual TKA discharged to a skilled nursing facility (12% vs. 8% vs. 15%; p<0.001) than those who had intraoperative technology utilized. FJS scores did not statistically differ at 3-months (p=0.067) and 1-year (p=0.221) postoperatively. There was a significant statistical difference in three-month KOOS, JR scores (59.48 vs. 60.10 vs. 63.64; p=0.001); however, one-year scores did not statistically differ between the three groups (p=0.320). Mean improvement in KOOS, JR scores preoperatively to one-year postoperatively was significantly largest for the navigation group and least for robotics (27.12 vs. 23.78 vs. 25.42; p<0.001). Conclusion. This study demonstrates shorter mean operative time in cases with no utilization of technology and clinically similar patient reported outcome scores associated with TKAs performed between all modalities. While the use of intraoperative technology may
Introduction. Clinical decision support tools are software that match the input characteristics of an individual patient to an established knowledge base to create patient-specific assessments that support and better inform individualized healthcare decisions. Clinical decision support tools can facilitate better evidence-based care and offer the potential for improved treatment quality and selection, shared decision making, while also standardizing patient expectations. Methods. Predict+ is a novel, clinical decision support tool that leverages clinical data from the Exactech Equinoxe shoulder clinical outcomes database, which is composed of >11,000 shoulder arthroplasty patients using one specific implant type from more than 30 different clinical sites using standardized forms. Predict+ utilizes multiple coordinated and locked supervised machine learning algorithms to make patient-specific predictions of 7 outcome measures at multiple postoperative timepoints (from 3 months to 7 years after surgery) using as few as 19 preoperative inputs. Predict+ algorithms predictive accuracy for the 7 clinical outcome measures for each of aTSA and rTSA were quantified using the mean absolute error and the area under the receiver operating curve (AUROC). Results. Predict+ was released in November 2020 and is currently in limited launch in the US and select international markets. Predict+ utilizes an interactive graphical user interface to facilitate efficient entry of the preoperative inputs to generate personalized predictions of 7 clinical outcome measures achieved with aTSA and rTSA. Predict+ outputs a simple, patient-friendly graphical overview of preoperative status and a personalized 2-year outcome summary of aTSA and rTSA predictions for all 7 outcome measures to aid in the preoperative patient consultation process. Additionally, Predict+ outputs a detailed line-graph view of a patient's preoperative status and their personalized aTSA, rTSA, and aTSA vs. rTSA predicted outcomes for the 7 outcome measures at 6 postoperative timepoints. For each line-graph, the minimal clinically important difference (MCID) and substantial clinical benefit (SCB) patient-satisfaction improvement thresholds are displayed to
Background. The transverse acetabular ligament (TAL) has been described as an anatomic landmark to guide in the positioning of the acetabular component during total hip arthroplasty. On plain films, the radiographic teardrop (RT) has similarly been utilized as a measure of appropriate cup positioning. The goal of this study is to quantify the distance and location between the anatomic TAL and RT landmarks to aid in the positioning of acetabular component. Methods. Sixteen randomly selected cadaveric pelvises (eight male, eight female) underwent dissection. Radiographic markers were placed bilaterally at the anteromedial insertions of the TAL, and true anteroposterior (AP) pelvic radiographs of the cadavers were obtained. Distances between the markers and the lateral borders of the RT were measured. Results. The mean distance between the anteromedial insertion of the TAL and the lateral border of the RT in the male specimens was 11.8 [99% CI, 11.4 to 12.2] mm. In the female specimens, the TAL to RT distance was shorter, with a mean of 8.4 [99% CI, 7.2 to 9.6] mm. There was a statistically significant difference between male and female cadavers (p<0.01). Conclusions. The distance between the RA and TAL differs between males and females. Understanding the distance between these anatomic and radiographic landmarks should
Instrumented fusion for lumbar degenerative spondylolisthesis (LDS) has been challenged recently with high impact trials demonstrating similar changes in health-related quality of life (HRQOL) and less morbidity/cost with laminectomy alone. Randomized trials often fail, however, to evaluate a heterogeneous population of patients. A standardized clinical assessment and management plan (SCAMP) was created as a decision
Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail. A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.Aims
Methods
This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm3). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis.Aims
Methods
The surgical target for optimal implant positioning in robotic-assisted total knee arthroplasty remains the subject of ongoing discussion. One of the proposed targets is to recreate the knee’s functional behaviour as per its pre-diseased state. The aim of this study was to optimize implant positioning, starting from mechanical alignment (MA), toward restoring the pre-diseased status, including ligament strain and kinematic patterns, in a patient population. We used an active appearance model-based approach to segment the preoperative CT of 21 osteoarthritic patients, which identified the osteophyte-free surfaces and estimated cartilage from the segmented bones; these geometries were used to construct patient-specific musculoskeletal models of the pre-diseased knee. Subsequently, implantations were simulated using the MA method, and a previously developed optimization technique was employed to find the optimal implant position that minimized the root mean square deviation between pre-diseased and postoperative ligament strains and kinematics.Aims
Methods
Background. The constraint of total knee replacement (TKR) implants is not simply defined and many of the factors that influence it are not well understood. Variability in the constraint of different TKR implants designed for the same indication (e.g. cruciate-retaining, or posterior-stabilized) have been previously demonstrated, but these differences among implants have yet to be simply quantified. Furthermore, the relative importance of several variables on the implant constraint remains unknown. The purpose of this study was to quantify the differences in constraint that exist between different implant designs, and to examine the effects of axial load and flexion angle on the constraint of current cruciate-retaining (CR) TKR components. Methods. Four contemporary CR TKR designs underwent laxity testing using a multi-axis mechanical test machine. Implants were tested at flexion angles of 0°, 20°, 90° and maximum flexion and axial loads of 712 N (1 BW) and 1424 N (2 BW). Friction-free motion in all secondary degrees of freedom was allowed. Force-displacement curves were generated for each testing condition in both anterior-posterior (AP) and rotational tests. AP constraint (N/mm) and rotational constraint (Nm/deg) were then calculated. Results. Differences in the AP and rotational constraint of the various implants were identified. The rotating platform implant was the most AP constrained and least rotationally constrained of the implants studied. Among the fixed bearing implants, NexGen CR had less AP and rotational constraint than the Genesis II and PFC Sigma. Doubling the applied axial load during the laxity tests resulted in a significant increase in both AP (p<0.0001) and rotational (p<0.0001) constraint. AP and rotational constraint decreased with increasing flexion angles. Conclusion. The constraints of four contemporary CR TKR designs were quantitatively compared and ranked according to their calculated constraints. Differences in the constraint of these designs were identified. This quantitative analysis is an important step towards the creation of a clinically meaningful constraint index that would
Aims: Dynamic hip screw (DHS) is a common implant used for extracapsular fracture neck of femur. Accurate placement of the guide wires for the DHS insertion is the most important surgical step. In order to improve precision and accuracy of the guide wire placement, Computer Assisted Orthopaedic Surgery System (CAOSS) was used , which was developed at the University of Hull. Methods: CAOSS helps in surgical planning and
Aims: Dynamic hip screw (DHS) is a common implant used for extracapsular fracture neck of femur. Accurate placement of the guide wires for the DHS insertion is the most important surgical step. In order to improve precision and accuracy of the guide wire placement, Computer Assisted Orthopaedic Surgery System (CAOSS) was used which was developed at the University of Hull. Early clinical experience in 14 cases is presented. Methods: CAOSS helps in surgical planning and
Purpose. The incidence of hip displacement in children with cerebral palsy is approximately 30% in large population based studies. The purpose of this study was to report the long-term effect of hip surgery on the incidence of hip displacement using a newly validated Cerebral Palsy (CP) hip classification. Method. Retrospectively, a sub-group of 100 children who underwent surgery for hip displacement were identified from a large-population based cohort of children born with CP between January 1990 and December 1992. These children were followed to skeletal maturity and closure of their tri-radiate cartilage. All patients returned at maturity for clinical and radiographic examination, while caregivers completed the disease specific quality of life assessments. Patients were grouped according to motor disorder, topographical distribution and GMFCS. Radiographs were independently graded according to CP hip classification scheme to ensure reliability. Surgical Failures were defined as CP Grade > IV. Results. Ninety-seven children and 194 hips were available for final review. According to GMFCS, greater than half the children were GMFCS IV and V (67/94, 67%), 12 were II and 18 were III. Fifteen hips were dislocated or had salvage surgery for dislocation (15/194, 7.7%) at time of skeletal maturity. The majority of hips were graded Grade II and III (149/194, 76.8%). A total of 39 (39/194, 20%) hips were classified as surgical failure with 95% (37/39) hips occurring in GMFCS IV and V children. Conclusion. Using the CP hip classification scheme, the natural history and outcome of 100 children with CP at skeletal maturity have been described. Despite hip surveillance and surgical intervention GMFCS IV and V children are at the greatest risk for surgical failure at skeletal maturity. In this study, the majority of failures were associated with either no hip surveillance and/or index surgery at a non-specialist centre. In contrast, hip surveillance and index surgery at a specialist tertiary centre was associated with a very high probability of a successful outcome. This is the first population based cohort study of children with cerebral palsy followed from index surgery to skeletal maturity for hip displacement. Surgical success rates for the treatment of hip displacement in children with cerebral palsy have not previously been reported. This information will
Total knee arthroplasty (TKA) is a common surgery to relieve knee pain and increase range of motion due to osteoarthritis (OA) in older patients. Minimally invasive, computer navigated techniques are gaining popularity for knee replacement surgery. These techniques may have potential to provide better functional outcomes over a shorter period of time. Little data exists comparing the early functional recovery of patients following total knee replacement surgery performed using various common approaches. This study compares the functional gait of patients two months after surgery performed using one of four common approaches to determine if differences exist in the immediate recovery. This knowledge will
Objectives. All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors. Materials and Methods. A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05. Results. Overall, mean maximum tensile strength values were significantly higher for the traditional anchor (181.0 N, standard error (. se). 17.6) compared with the all-suture anchors (mean 133.1 N . se. 16.7) (p = 0.04). The JuggerKnot anchor had greatest displacement at 50, 100 and 150 cycles, and at failure, reaching statistical significance over the control at 100 and 150 cycles (22.6 mm . se. 2.5 versus 12.5 mm . se. 0.3; and 29.6 mm . se. 4.8 versus 17.0 mm . se. 0.7). Every all-suture anchor tested showed substantial (> 5 mm) displacement between 50 and 100 cycles (6.2 to 14.3). All-suture anchors predominantly failed due to anchor pull-out (95% versus 25% of traditional anchors), whereas a higher proportion of traditional anchors failed secondary to suture breakage. Conclusion. We demonstrate decreased failure load, increased total displacement, and variable failure mechanisms in all-suture anchors, compared with traditional anchors designed for rotator cuff repair. These findings will
Introduction. Severe osteolysis of the femur secondary to aseptic loosening in hip arthroplasty, remains a difficult revision scenario. Multiple techniques have been developed to
Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods. Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement.Aims
Methods
The Delto-pectoral approach is the workhorse of the shoulder surgeon, but surprisingly the common variants of the cephalic vein and deltoid artery have not been documented. The vascular anatomy encountered during one hundred primary elective delto-pectoral approaches was documented and common variants described. Two common variants are described. A type I (71%), whereby the deltoid artery crosses the interval and inserts directly in to the deltoid musculature. In this variant the surgeon is unlikely to encounter any vessels crossing the interval apart from the deltoid artery itself. In a type II pattern (21%) the deltoid artery runs parallel to the cephalic vein on the deltoid surface and is highly likely to give off medial branches (95%) that cross the interval, as well as medial tributaries to the cephalic vein (38%). Knowledge of the two common variants will
Three distal femoral axes have been described to aid in alignment of the femoral component; the Trans Epicondylar Axis (TEA), the Posterior Condylar Axis (PCA) and the Antero Posterior (AP) axis. Our aim was to identify if there was a reproducible relationship between the axes. Hopefully this will
Purpose. Intra-articular fractures of the distal radius are common injuries. Their pathogenesis involves a complex combination of forces, including ligament tension, bony compression and shearing, leading to injury patterns that challenge the treating surgeon. The contribution of the radiocarpal and radioulnar ligaments to articular fracture location has not previously been described. Computed tomography (CT) scanning is an important method of evaluating intra-articular distal radius fractures, revealing details missed on plain radiographs and influencing treatment plans. Methods. We retrospectively reviewed CT scans of acute intra-articular distal radius fractures performed in one institution from June 2001 to June 2008. Forty- five of 145 scans were deemed unsuitable due to poor quality or presence of internal fixation in the distal radius, leaving 100 fractures for review. Fracture line locations were mapped to a standardised distal radius model, and statistically analysed in their relationship to ligament attachment zones. Results. Distal radius articular fracture lines are significantly less likely to occur in the regions of ligament attachment. Conversely, fracture lines are more likely to occur in the gaps between major ligament attachments. Conclusion. Articular fracture locations in the distal radius are significantly related to radiocarpal and radioulnar ligament attachments. This may